• 제목/요약/키워드: Biomechanical Properties

검색결과 100건 처리시간 0.026초

Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes

  • Lee, Hun;Kang, David Sung Yong;Ha, Byoung Jin;Choi, Jin Young;Kim, Eung Kweon;Seo, Kyoung Yul;Kim, Tae-im
    • Yonsei Medical Journal
    • /
    • 제59권9호
    • /
    • pp.1115-1122
    • /
    • 2018
  • Purpose: To investigate biomechanical properties of the cornea using a dynamic Scheimpflug analyzer according to age. Materials and Methods: In this prospective, cross-sectional, observational study, participants underwent ophthalmic investigations including corneal biomechanical properties, keratometric values, intraocular pressure (IOP), and manifest refraction spherical equivalent (MRSE). We determined the relationship of biomechanical parameters and ocular/systemic variables (participant's age, MRSE, IOP, and mean keratometric values) by piecewise regression analysis, association of biomechanical parameters with variables by Spearman's correlation and stepwise multiple regression analyses, and reference intervals (RI) by the bootstrap method. Results: This study included 217 eyes of 118 participants (20-81 years of age). Piecewise regression analysis between Corvis-central corneal thickness (CCT) and participant's age revealed that the optimal cut-off value of age was 45 years. No clear breakpoints were detected between the corneal biomechanical parameters and MRSE, IOP, and mean keratometric values. Corneal velocity, deformation amplitude, radius, maximal concave power, Corvis-CCT, and Corvis-IOP exhibited correlations with IOP, regardless of age (all ages, 20-44 years, and over 44 years). With smaller deformation amplitude and corneal velocity as well as increased CorvisIOP and Corvis-CCT, IOP became significantly increased. We provided the results of determination of confidence interval from RI data using bootstrap method in three separate age groups (all ages, 20-44 years, and over 44 years). Conclusion: We demonstrated multiple corneal biomechanical parameters according to age, and reported that the corneal biomechanical parameters are influenced by IOP.

The biomechanical and biological effect of supercooling on cortical bone allograft

  • MuYoung Kim ;Hun-Young Yoon
    • Journal of Veterinary Science
    • /
    • 제24권6호
    • /
    • pp.79.1-79.16
    • /
    • 2023
  • Background: The need for a storage method capable of preserving the intrinsic properties of bones without using toxic substances has always been raised. Supercooling is a relatively recently introduced preservation method that meets this need. Supercooling refers to the phenomenon of liquid in which the temperature drops below its freezing point without solidifying or crystallizing. Objectives: The purpose of this study was to identify the preservation efficiency and applicability of the supercooling technique as a cortical bone allograft storage modality. Methods: The biomechanical effects of various storage methods, including deep freezing, cryopreservation, lyophilization, glycerol preservation, and supercooling, were evaluated with the three-point banding test, axial compression test, and electron microscopy. Additionally, cortical bone allografts were applied to the radial bone defect in New Zealand White rabbits to determine the biological effects. The degree of bone union was assessed with postoperative clinical signs, radiography, micro-computed tomography, and biomechanical analysis. Results: The biomechanical properties of cortical bone grafts preserved using glycerol and supercooling method were found to be comparable to those of normal bone while also significantly stronger than deep-frozen, cryopreserved, and lyophilized bone grafts. Preclinical research performed in rabbit radial defect models revealed that supercooled and glycerol-preserved bone allografts exhibited significantly better bone union than other groups. Conclusions: Considering the biomechanical and biological superiority, the supercooling technique could be one of the optimal preservation methods for cortical bone allografts. This study will form the basis for a novel application of supercooling as a bone material preservation technique.

인조고막용 키토산 패치 지지체의 생체역학적 특성 및 독성 평가 (Biomechanical Properties and Cytotoxicity of Chitosan Patch Scaffold for Artificial Eardrum)

  • 정종훈;김장호;정연훈;임애리;임기택;홍지향;정필훈
    • Journal of Biosystems Engineering
    • /
    • 제32권1호
    • /
    • pp.57-62
    • /
    • 2007
  • The objectives of this study were to prepare a new artificial eardrum patch using water-insoluble chitosan for healing the tympanic membrane perforations and to investigate biomechanical properties and cyotoxicity of the chitosan patch scaffold (CPS). Tensile strength and elongation at the rupture point of CPSs were 2.49-74.05 MPa and 0.11-107.06%, respectively. As the biomechanical properties or CPSs varied with the concentration of chitosan and glycerol, the proper conditions for the CPS were found out. SEM analysis showed very smooth and uniform surface of CPSs without pores at x1000. The result of MTT test showed that CPSs had no cytotoxicity.

대퇴골 전자간부 해면골의 미세구조적 특성과 생역학적 특성에 관한 연구 (A study on the micro-structural and biomechanical properties of trabecular bone in intertrochanteric region)

  • 백명현;원예연;최문권;김광균;김한성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.923-926
    • /
    • 2005
  • To investigate the relationship between BMD, micro-structural and mechanical properties in intertrochanteric trabecular bone, the PIXI-mus2 system, micro-CT and FE model were used. The purpose of this study were (1) to apply high-resolution imaging techniques (micro-CT imaging) in combination with new computer modeling techniques (FEA) to quantify 3D microstructural and biomechanical properties of trabecular bone in the intertrochanteric region, and (2) determine if the prediction of bone elastic constant can be improved with structural index.

  • PDF

척추성형술 시술에서 요추의 생체역학적 특성 변화 (Biomechanical Property Change of Vertebral body in Vertebroplasty)

  • 이준형;전성재;채수원;이태수;서중근;박정율;김상돈;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1324-1327
    • /
    • 2003
  • The compressed fracture of spine caused by osteoporosis is one of the most frequent diseases in bone fracture. Recently the vertebroplasty has drawn much attention as a medical treatment for the compressed fracture of spine, which strengthens the vertebral body and corrects deformity, and relieves pain in patients by injecting bone cement. The finite element analysis is used to investigate the vertebroplasty quantitatively. Previous works with finite element analysis have drawbacks in their simplified models geometry of vertebral body and with material properties of bone. In this paper the exact geometry of vertebral body has been constructed from medical image data and the biomechanical property changes of vertebral body in vertebroplasty have been investigate by using three dimensional finite element analysis.

  • PDF

Comparison of Biomechanical Properties of Dura Mater Substitutes and Cranial Human Dura Mater : An In Vitro Study

  • Kizmazoglu, Ceren;Aydin, Hasan Emre;Kaya, Ismail;Atar, Murat;Husemoglu, Bugra;Kalemci, Orhan;Sozer, Gulden;Havitcioglu, Hasan
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권6호
    • /
    • pp.635-642
    • /
    • 2019
  • Objective : The aim of this study was to investigate the biomechanical differences between human dura mater and dura mater substitutes to optimize biomimetic materials. Methods : Four groups were investigated. Group I used cranial dura mater (n=10), group II used $Gore-Tex^{(R)}$ Expanded Cardiovascular Patch (W.L. Gore & Associates Inc., Flagstaff, AZ, USA) (n=6), group III used $Durepair^{(R)}$ (Medtronic Inc., Goleta, CA, USA) (n=6), and group IV used $Tutopatch^{(R)}$ (Tutogen Medical GmbH, Neunkirchen am Brand, Germany) (n=6). We used an axial compression machine to measure maximum tensile strength. Results : The mean tensile strengths were $7.01{\pm}0.77MPa$ for group I, $22.03{\pm}0.60MPa$ for group II, $19.59{\pm}0.65MPa$ for group III, and $3.51{\pm}0.63MPa$ for group IV. The materials in groups II and III were stronger than those in group I. However, the materials in group IV were weaker than those in group I. Conclusion : An important dura mater graft property is biomechanical similarity to cranial human dura mater. This biomechanical study contributed to the future development of artificial dura mater substitutes with biomechanical properties similar to those of human dura mater.

골밀도를 고려한 척추성형술의 생체역학적 평가 (Biomechanical Evaluation of the Vertebroplasty Based on Bone Density)

  • 김동율;이태수;박정율;서중근;최귀원;채수원
    • 한국정밀공학회지
    • /
    • 제23권8호
    • /
    • pp.185-194
    • /
    • 2006
  • In this paper, three dimensional finite element analyses have been performed to investigate the biomechanics of vertebroplasty in patient accurate FE models have been constructed from CT images of a PMMA injected vertebra. In order to apply various material properties of the spine(T12), the functional relation between the well known apparent density and HU(Hounsfield unit) from CT image were employed and thus real material properties can be assigned to each element of FE model. The FE analysis showed similar results with the experiments. With this approach accurate analysis of the vertebroplasty and its clinical applications can be expected.

생체재료를 설명하는 스트레인 에너지 함수에 대한 이론적 고찰 (Theoretical Framework For Describing Strain Energy Function on Biomaterial)

  • 강태원
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.50-55
    • /
    • 2013
  • In order to understand the biomaterial like the blood vessel of artery, there is a need to quantify the biomechanical behavior of the vessel. However, theoretical framework to describe and quantify the behaviour of blood vessel was not well established so far. For studying the biomechanical behavior of artery, Rubber-liked material which is similar to passive artery is selected since conventional theoretical interpretation is very limited to understand and predict the behavior of biomaterial. Rubber-like material is assumed to be very similar to artery and has properties of isotropy, homogeneity and is undergoing large deformation. Based on this assumption, stress developed on Rubber-like material is described by strain energy function and strain invariants which are required to understand the nonlinear elastic behavior of biomaterial. The descriptor which would be used for understanding the biomechanical behavior of artery is studied in this work.

신발 설계 및 평가를 위한 컴퓨터 모델 (REVIEW OF COMPUTATIONAL MODELS FOR FOOTWEAR DESIGN AND EVALUATION)

  • Cheung, Jason Tak-Man;Yu, Jia;Zhang, Ming
    • 한국운동역학회지
    • /
    • 제19권1호
    • /
    • pp.13-25
    • /
    • 2009
  • Existing footwear biomechanics studies rely on simplified kinetics and kinematics, plantar pressure and muscle electromyography measurements. Because of the complexity of foot-shoe interface and individualized subject response with different footwear, consistent results regarding the biomechanical performance of footwear or footwear components can yet be achieved. The computational approach can be an efficient and economic alternative to study the biomechanical interactions of foot and footwear. Continuous advancement in numerical techniques as well as computer technology has made the finite element method a versatile and successful tool for biomechanics researchdue to its capability of modelling irregular geometrical structures, complex material properties, and complicated loading and boundary conditions. Finite element analysis offers asystematic and economic alternative in search of more in-depth biomechanical information such as the internal stress and strain distributions of foot and footwear structures. In this paper, the current establishments and applications of the computational approach for footwear design and evaluation are reviewed.

Applications of Bioinspired Platforms for Enhancing Immunomodulatory Function of Mesenchymal Stromal Cells

  • Ok-Hyeon Kim;Tae Jin Jeon;Young In So;Yong Kyoo Shin;Hyun Jung Lee
    • International Journal of Stem Cells
    • /
    • 제16권3호
    • /
    • pp.251-259
    • /
    • 2023
  • Mesenchymal stromal cells (MSCs) have attracted scientific and medical interest due to their self-renewing properties, pluripotency, and paracrine function. However, one of the main limitations to the clinical application of MSCs is their loss of efficacy after transplantation in vivo. Various bioengineering technologies to provide stem cell niche-like conditions have the potential to overcome this limitation. Here, focusing on the stem cell niche microenvironment, studies to maximize the immunomodulatory potential of MSCs by controlling biomechanical stimuli, including shear stress, hydrostatic pressure, stretch, and biophysical cues, such as extracellular matrix mimetic substrates, are discussed. The application of biomechanical forces or biophysical cues to the stem cell microenvironment will be beneficial for enhancing the immunomodulatory function of MSCs during cultivation and overcoming the current limitations of MSC therapy.