• Title/Summary/Keyword: Biological imaging

Search Result 688, Processing Time 0.034 seconds

Patch-based Cortical Source Modeling for EEG/MEG Distributed Source Imaging: A Simulation Study

  • Im Chang-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.2
    • /
    • pp.64-72
    • /
    • 2006
  • The present study introduces a new cortical patch-based source model for EEG/MEG cortical source imaging to consider anatomical constraints more precisely. Conventional source models for EEG/MEG cortical source imaging have used coarse cortical surface mesh or sampled small number of vertices from fine surface mesh, and thus they failed to utilize full anatomical information which nowadays we can get with sub-millimeter modeling accuracy. Conventional ones placed a single dipolar source on each cortical patch and estimated its intensity by means of various inverse algorithms; whereas the suggested cortical patch-based model integrates whole cortical area to construct lead field matrix and estimates current density that is assumed to be constant in each cortical patch. We applied the proposed and conventional models to realistic EEG data and compared the results quantitatively. The quantitative comparisons showed that the proposed model can provide more precise spatial descriptions of neuronal source distribution.

Imaging Gene Expression (유전자 발현 영상기법)

  • Lee, Kyung-Han
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • The rapid progress of molecular genetic methods over the past two decades has necessitated the development of methods to detect and quantify genetic activity within living bodies. Reporter genes provide a rapid and convenient tool to monitor gene expression by yielding a readily measurable phenotype upon expression when introduced into a biological system. Conventional reporter systems, however, are limited in their usefulness for in vivo experiments or human gene therapy because of its invasive nature which requires cell damage before assays can be performed. This offers an unique opportunity for nuclear imaging techniques to develope a novel method for imaging both the location and amount of gene expression noninvasively. Current developments to achieve this goal rely on utilizing either reporter enzymes that accumulate radiolabeled substrates or reporter receptors that bind specific radioligands. This overview includes a brief introduction to the background for such research, a summary of published results, and an outlook for future directions.

  • PDF

Reduction of Susceptibility Artifact in MR Gradient Echo Imaging (MR Gradient Echo 영상술에서 자화율에 의한 에러의 감소에 관한 연구)

  • Ro, Y.M.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.19-23
    • /
    • 1990
  • A new technique for reducing the susceptibility artifact in gradient echo imaging which uses a tailored RF pulse is proposed. It is applied to the case of imaging where artifacts and distortions arise due to the high local magnetic field inhomogeneity i. e., the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method using a tailored RF pulse is proposed. Applications of this method in imaging are given and experimental results obtained using an human volunteer with a 2.0 T KAIS NMR system are presented.

  • PDF

Recent Development in Low Dose Nuclear Medicine Gamma Camera Imaging (저선량 핵의학 감마카메라 영상장치의 최근 발전)

  • Hwang, Kyung Hoon;Lee, Byeong-il;Kim, Yongkwon;Lee, Haejun;Sun, Yong Han
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.123-127
    • /
    • 2015
  • Recently, new gamma camera systems enabling low radiation dose imaging have been developed. We reviewed the recent development of these low dose gamma camera systems including high sensitivity detectors, device structures, noise reduction filters, efficient image reconstruction algorithms, low dose protocols, and so on. It is expected that further technological advances reduce both radiation dose and imaging time in gamma camera imaging especially for radiation-sensitive patients such as pediatric patients.

Detection of Intracellular Free Metal Ions with Molecular Two-Photon Sensors (이광자 분자센서를 이용한 생체 내 금속이온 검출)

  • Kim, Hwan-Myung
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.231-237
    • /
    • 2011
  • Two-photon microscopy (TPM) is attracting much attention in biological imaging due to the capability of imaging deep inside the living tissues for a long period of time. For maximum utilization of TPM, it is essential to develop efficient twophoton sensors. Regarding this, many research groups are developing two-photon sensors for specific applications. In this review, we summarize recent results on selected examples of two-photon sensors for intracellular free metal ions in the live cells and tissues to provide a guideline for various imaging applications.

Improvement of SNR in DANTE Fast MR Imaging (MR DANTE 고속 영상에서 SNR의 개선에 관한 연구)

  • 정성택
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.87-96
    • /
    • 1997
  • A pixel profile in the conventional DANTE sequence is so poor that the excited area by DANTE sequence is a small portion of a pixel. This causes poor signal to noise ratio in DANTE image. In this paper, a frequency modulated(FM) DANTE imaging sequence is proposed to improve pixel profile in DANTE image. A DANTE pulse train is shaped by an FM function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on the sweep in FM signal. Computer simulations and experimental result obtained using a 7.0 T NMR imaging system are presented.

  • PDF

Shielded High-Order Gradient Coil Design for Magnetic Resonance Spectroscopy and Imaging (자기공명분석과 영상촬영을 위한 차폐된 고차경사자계코일의 설계)

  • Oh, Chang-Hyun;Hilal, Sadek K.;Yi, Yun;Kim, Min-Gi
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.45-48
    • /
    • 1993
  • High-order field gradients are useful for spatial localization of a volume of interest and dynamic range improvement of signal detection in NMR (Nuclear Magnetic Resonance) spectroscopy and imaging. This paper proposes a design method of shielded high-order gradient coils to reduce tile effect of eddy current on tile spectroscopy and imaging results. According to the experimental results, the shielded gradient coils produce less than 2 % eddy current compared to non-shielded coils. Two shielded $z^2$ gradient coils have been designed and constructed for 1.5 T whole-body and 3.0 T animal NMR imaging systems. Experimental results are in good agreement with the theoretically expected behavior and show the utility of the shielded high-order gradient coils.

  • PDF

An Efficient Focusing Method for High Resolution Ultrasound Imaging

  • Kim Kang-Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.22-29
    • /
    • 2006
  • This paper proposes an efficient array beamforming method using spatial matched filtering for ultrasound imaging. In the proposed method, ultrasound waves are transmitted from an array subaperture with fixed transmit focus as in conventional array imaging. At receive, radio frequency (RF) echo signals from each receive channel are passed through a spatial matched filter that is constructed based on the system transmit-receive spatial impulse response. The filtered echo signals are then summed. The filter remaps and spatially registers the acoustic energy from each element so that the pulse-echo impulse response of the summed output is focused with acceptably low side lobes. Analytical beam pattern analysis and simulation results using a linear array show that the proposed spatial filtering method can provide more improved spatial resolution and contrast-to-noise ratio (CNR) compared with conventional dynamic receive focusing (DRF) method by implementing two-way dynamically focused beam pattern throughout the field.