• Title/Summary/Keyword: Biological Pump

Search Result 107, Processing Time 0.021 seconds

An Estimation of the New Production in the Southern East Sea Using Helium Isotopes

  • Kim, Kyung-Ryul;Hahm, Do-Shik
    • Journal of the korean society of oceanography
    • /
    • v.36 no.1
    • /
    • pp.19-26
    • /
    • 2001
  • The biological pump is one of the important pumping mechanisms absorbing CO$_2$ from the atmosphere into the ocean and can be quantified by estimating new production. New production in the open ocean mostly depends on the supply of nitrate from the water below the mixed layer. While nitrate is affected by many biological processes, the helium isotope ($^3$He) is inert and has very simple physical properties. Using the $^3$He flux and the relation between $^3$He and NO${_3}\;{^-}$- within the thermocline, the nitrate flux supporting new production was estimated in the southern East Sea. The average ${\delta}^3$He within the mixed layer was -14$%_o$ and -l5.4$%_o$ in the winter and autumn, respectively. Through the year excess $^3$He occurs in the mixed layer except for a slight depletion of -17$%_o$ in summer. The $^3$He flux of 13$%_o$md$^{-1}$ associated with the concentration gradient at the air-sea interface was calculated from the product of the piston velocity and the excess $^3$He. Tritium decay within the mixed layer could support only 2$%_o$md$^{-1}$ of the flux. Thus, the remaining 11$%_o$md^{-1}$ could be attributed to the flux of tritiugenic $^3$He from the water below the mixed layer. Nitrate and $^3$He were positively correlated within the thermocline layer with the slope of 0.21 ${\mu}$mol kg$^{-1}$ $%_o\;^{-1}$. The annual nitrate flux estimated from the upward flux of $^3$He and the NO$_{3}\;{^-}$-$^3$He relation was 0.8${\pm}$0.2 mol(N) m$^{-2}$yr$^{-1}$. This flux corresponds to an annual new production of 64 g(C) m$^{-2}$yr$^{-1}$, which is consistent with that in the north-west Pacific.

  • PDF

Analysis on the Blood F1ow, Pressure and Pulsatility of a Dual Pulsatile Extracorporeal Life Support (이중 박동형 생명구조장치의 혈류, 혈압, 박동성의 분석)

  • Choi, Seong-Wook;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.684-693
    • /
    • 2007
  • Previous trials for development of a pulsatile-Extracorporeal Life Support had some defects such as insufficient blood flow, high pressure at its membrane oxygenator and the high risk of blood cell damage. To solve those problems of previous pulsatile-ECLSs, we suggest dual pulsatile blood pump structure for the new pulsatile-ECLS. Two pulsatile pumps areconnected in a parallel manner and this new structure raises the inflow capacity and efficiency and it decreases the high blood pressure at membrane oxygenator. In in-vitro experiments, The Energy Equivalent Pressure Increment(EEP inc.) was 10%, and it showed that its pulsatilty was $5{\sim}10$ times higher than other commercial ECLS In in-vivo experiments, we had applied a new pulsatile-ECLS to 30 Kg pigs and a new pulsatile-ECLS couldsupport high blood flow and pulsatility above 2 L/min, 10% EEP inc.

Effects of Yijin-tang-gamibang Extracts on Reflux Esophagitis (역류성 식도염에 대한 이진탕가미방(二陣湯加味方) 효과 연구)

  • Hwang, Gee-Young;Kim, Dae-Jun;Byun, Joon-Seok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1073-1079
    • /
    • 2009
  • The object of this study was to observe the protective effects of Yijin-tang-gamibang (YJGMB), Yijin-tang has been traditionally used as Korean medicine for treating various digestive diseases. The study showed that it is effective on reflux esophagitis induced by pylorus and forestomach ligation in rats. Three different dosages of Yijin-tang-gamibang extracts, 300, 150 and 75 mg/kg, were once orally administered 1 hour before pylorus ligation. 6 groups, each of 8 rats per group were used in the present study. The results were compared with Omeprazole, antioxidant and proton pump inhibitor, 30 mg/kg treated group. Yijin-tang-gamibang extracts 300 mg/kg were showed similar or slightly lower effects as compared with 30 mg/kg of omeprazole in the present study. Detail mechanism studies should be conduced in future with the efficacy tests of individual herbal composition of Yijin-tang-gamibang and the screening of the biological active compounds in herbs.

Effect of Structured Information on Immediate Preoperative Anxiety and Uncertainty for Women Undergoing Laparoscopic Hysterectomy (수술 전 구조화된 정보제공이 복강경하 자궁절제술 여성의 수술대기 중 불안과 불확실성에 미치는 효과)

  • Cho, Youn Hee;Chun, Nami
    • Women's Health Nursing
    • /
    • v.21 no.4
    • /
    • pp.321-331
    • /
    • 2015
  • Purpose: Purpose of this study was to identify the effect of structured information on immediate preoperative anxiety and uncertainty for women undergoing total laparoscopic hysterectomy. Methods: Sixty women who were admitted for total laparoscopic hysterectomy were recruited at a university hospital in Gyeonggi-do from June to October 2014. Thirty women were assigned to either the experimental or the control group. Women in the experimental group were provided structured information, which consisted of visual and auditory materials about surgical preparation and process, practical experience on devices such as IV-PCA pump and Inspiro-meter and actual experience on route to go to the operating room. State-anxiety, uncertainty, and blood pressure and pulse rate as biological indicators were measured before and after the intervention to examine the effect. Results: Significant group differences were found on state anxiety, uncertainty, including ambiguity, inconsistency, and unpredictability at the holding area. There was a significant difference on pulse rate in the operating room between the two groups. Conclusion: Findings demonstrated that the structured information provided for women undergoing laparoscopic hysterectomy preoperatively was effective on immediate preoperative anxiety and uncertainty. Nurses may contribute to decreasing patients' anxiety and uncertainty by utilizing this structured information preoperatively.

Changes in Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation: an In Vitro Study

  • Lee, Chong-Sun;Kim, Joo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.193-197
    • /
    • 2005
  • Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of intracranial pressure pulsation on their flow control characteristics. Five commercial shunt valves were tested in the flow loop that simulates pulsed flow under pressure pulsation. As 20cc/hr of flow rate was adjusted at a constant pressure, application of $40mmH_2O$ of pressure pulse increased the flow rate by $67.9\%.$ As a 90cm length catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to $17.5\%.$ As the flow rate was adjusted to 40cc/hr at a constant pressure, increase in the flow rate was $51.1\%$ with the same pressure pulsation of $40mmH_2O$. The results indicated that pressure-flow control characteristics of shunt valves implanted above human brain ventricle is quite different from those obtained by syringe pump test at constant pressures right after manufacture. The influence of pressure pulsation was observed to be more significant at low flow rate and the flexibility of the outlet silicone catheter was estimated to significantly reduce flow increase due to pressure pulsation.

Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture

  • Oh, Tong-In;Baek, Sang-Min;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.215-221
    • /
    • 2005
  • We describe the development of a prototype multi-channel electrical impedance tomography (EIT) system. The EIT system can be equipped with either a single-ended current source or a balanced current source. Each current source can inject current between any chosen pair of electrodes. In order to reduce the data acquisition time, we implemented multiple digital voltmeters simultaneously acquiring and demodulating voltage signals. Each voltmeter measures a differential voltage between a fixed pair of adjacent electrodes. All voltmeters are configured in a radially symmetric architecture to optimize the routing of wires and minimize cross-talks. To maximize the signal-to-noise ratio, we implemented techniques such as digital waveform generation, Howland current pump circuit with a generalized impedance converter, digital phase-sensitive demodulation, tri-axial cables with both grounded and driven shields, and others. The performance of the EIT system was evaluated in terms of common-mode rejection ratio, signal-to-noise ratio, and reciprocity error. Future design of a more innovative EIT system including battery operation, miniaturization, and wireless techniques is suggested.

Development of an IV Infusion Rate Regulator Using Optical Drip Rate Meter (광센서 점적계를 이용한 정맥내 주입률 조절기의 개발)

  • Yang, Y.S.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.127-128
    • /
    • 1998
  • It is necessary to maintain constant intravenous (IV) infusion rate. While infusion pump is able to control infusion rate with great accuracy, its rather large size and weight make it difficult for patients to move around. The most commonly used infusion device is gravity IV infusion set with its administration chamber being clamped according to the observed drip rate. In this case it may be easier and more accurate to maintain IV rate to given value if we automate the drip-counting process and tube-clamping work by electronic devices. We calculated volume infusion rate of specific fluid using optical drip rate meter which we had developed. To regulate fluid flow rate, we equipped the rate meter which we had developed with a miniaturized clamping apparatus using DC motor. Also, we Implemented drip detection and clamp control algorithm with PIC16C73 $\mu$-controller (Microchip). This system provides user interface through LCD display and key buttons.

  • PDF

Energetics of the Heart Model with the Ventricu1ar Assist Device

  • Chung, Chanil-Chung;Lee, Sang-Woo;Han, Dong-Chul;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.43-48
    • /
    • 1996
  • We investigated the energistics of the physiological heart model by comparing predictive indexes of the myocardial oxygen consumption (MOC), such as tension-time index (R), tension-time or force-time inteual (FTI), rate-pressure product (RPP), pressure-work index, and systolic pressure-volume area (PVA) when using the electro-hydraulic left ventricular device (LVAD). We developed the model of LVAD incorporated the closed-loop cardiovascular system with a baroreceptor which can control heart rate and time-varying elastance of left and right ventricles. On considering the benefit of the LVAD, the effects of various operation modes, especially timing of assistance, were evaluated using this coupled computer model. Overall results of the computer simulation shows that our LVAD can unload the ischemic (less contractile) heart by decreasing the MU and increasing coronary flow. Because the pump ejection at the end diastolic phase of the natural heart may increase the afterload of the left ventricle, the control scheme of our LVAD must prohibit ejecting at this time. Since the increment of coronary flow is proportional to the peak aortic pressure after ventricle contraction, the LVAD must eject immediately following the closure of the aortic valve to increase oxygen availability.

  • PDF

In-vivo Evaluation of Pneumatic Ventricular Assist Device and Durability Improvement (공압식 심실보조장치의 in-vivo 평가 및 내구성 개선)

  • 이상훈;이광호;박성식;서필원;김삼현;강봉진
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.65-70
    • /
    • 2004
  • In this paper, we described 23 cases of animal experiment with our pneumatic ventricular assist device and new durability-improvement method. The blood pump consists of blood housing, and back plate made by the injection molding of isoplast, and the diaphragm fabricated by dipping of polyurethane solution onto the aluminum mold. Its volume was 75 $m\ell$ and in-vitro test showed that maximum output was 4.5 $\ell$/min at the 100 mmHg. The adult female sheep with weight of 50 + 10 kg were employed for tile in-vivo experiments and the mean blood flow was sustained at 3.0 1/min. 4 animals survived more than 15 days and the longest survival time was 28 days. In the prior 10 cases, the major causes of death were the tearing of diaphragm at the diaphragm to blood housing junction. By the new mesh and alumina ball milling methods, the durability was enhanced, and its qualitative and quantitative improvement was proved via the in-vivo and in-vitro methods. Animal experiments demonstrated that all the physiologic parameters a ere maintained within the permissible ranges and no thrombus formation was observed through the visual and blood test. The in-vivo experiments demonstrated our pneumatic ventricular assist device to he one month's bridge to transplantation device.

Changes in The Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation (뇌압 펄스에 의한 션트밸브의 압력-유량제어 특성의 변화)

  • 홍이송;이종선;장종윤
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.391-395
    • /
    • 2002
  • Shunt valves used to treat patient with hydrocephalus were numerically simulated to investigate influence of pressure pulsation on their flow control characteristics. We modeled flow orifice through the shunt valve and imposed pulsating pressure and valve diaphragm movement to compute flow through the valve. The results of our study indicated that flow rates increased more than 40% by introducing pressure pulsation and diaphragm movement on the shunt valve. Our results demonstrate the pressure-flow control characteristics of shunt valves implanted above human brain may be quite different from those obtained by syringe pump test just after manufacture that induces uniform pressure.