• 제목/요약/키워드: Biofilter Biofiltration

검색결과 77건 처리시간 0.024초

생물살수여과법을 이용한 공기 중 VOC 제거 기술 (Technology of VOC Removal in Air by Biotrickling Filter)

  • 원양수
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.101-112
    • /
    • 2003
  • Biological methods are frequently used for treatment of contaminated air, containing volatile organic compounds and odor compounds in low concentrations and high flow rate of air streams. For more than 20 years. biofilter has been recognized as a cost effective technology for the purification of contaminated air. Most commercial applications before 1990 were for control of odors. In the past decades major progress has been accomplished in the development of vapor phase bioreactor. in particular biotrickling filers. Biotrickling filters are more complex than biofilters. but are usually more effective, especially for the treatment of compounds which are difficult to degrade or compounds that generate acidic by-products. While the level of understanding of biotrickling filtration process for VOCs still remains limited. the evidence success of biotreatment of VOC in air resulted in pursuing active research. This paper presents fundamental and practical aspert of VOCs treatment from air in biotrickling filter. Special emphasis is given to the operating parameters and the factors influencing performance for biotrickling filter.

질소산화물 제거를 위한 최적 토양 바이오 필터 혼합비 도출에 관한 연구 (A Study of Optimal Mixture Fraction of Soil Bio-Filter for Removing NOX)

  • 조기철;이내현
    • 한국환경과학회지
    • /
    • 제16권11호
    • /
    • pp.1247-1255
    • /
    • 2007
  • Soil biofiltration is an environmentally-sound technology for elimination of VOCs, odorous and $NO_X$ compounds from a low concentration, high volume waste gas streams because of its simplicity and cost-effectiveness. This study investigated the optimal mixture fraction of briquet ash, compost, soil and loess for $NO_X$ degradation. Extreme vertices design was used to examine the role of four components on $NO_X$ degradation. Under our experimental conditions, 74.5% of $NO_X$ degradation was observed, using a model mixture(25% briquet ash, 10% compost, 30% soil and 40% loess) containing 100 ppb of NO. It was shown that experimental design analysis could allow selecting optimal conditions in such biodegradation processes in this study.

O3/BAC 공정에서 Peroxone 공정 적용에 따른 잔류 과산화수소 제거 특성 (Removal Characteristics of Residual Hydrogen Peroxide (H2O2) according to Application of Peroxone Process in O3/BAC Process)

  • 염훈식;손희종;서창동;김상구;류동춘
    • 대한환경공학회지
    • /
    • 제35권12호
    • /
    • pp.889-896
    • /
    • 2013
  • 수중의 미량 유해물질 제거를 위해 AOP 공정에 대한 관심이 증대되고 있다. 낙동강 하류에 위치한 정수장들은 대부분 $O_3/BAC$ 공정을 채택하여 운전 중에 있으며, AOP 공정의 일종인 peroxone 공정의 적용에 많은 관심을 가지고 있다. 본 연구에서는 $O_3/BAC$ 공정을 운전 중인 정수장에서 과산화수소를 투입할 경우에 후단의 BAC 공정에서의 잔류 과산화수소의 제거 특성을 biofiltration 공정과 함께 평가하였다. 유입수의 수온 및 과산화수소 농도변화 실험에서 biofilteration 공정은 낮은 수온에서 유입수 중의 과산화수소 농도가 증가하면 급격히 생물분해능이 저하된 반면, BAC 공정에서는 비교적 안정적인 효율을 유지하였다. 유입수의 수온을 $20^{\circ}C$, 과산화수소 투입농도를 300 mg/L로 고정하여 78시간 동안 연속으로 투입한 실험에서 biofilteration 공정은 EBCT 5~15분의 경우 운전 24~71시간 후에는 유입된 과산화수소가 거의 제거되지 않았으나, BAC 공정에서는 78시간 후의 과산화수소 제거율이 EBCT 5~15분일 때 38%~91%로 나타났다. 또한, 78시간 동안 연속 투입실험 후의 biofilter와 BAC 부착 박테리아들의 생체량과 활성도는 각각 $6.0{\times}10^4CFU/g$$0.54mg{\cdot}C/m^3{\cdot}hr$$0.4{\times}10^8CFU/g$$1.42mg{\cdot}C/m^3{\cdot}hr$로 나타나 운전초기에 비해 biofilter에서는 생체량과 활성도가 각각 99%와 72% 감소하였으며, BAC의 경우는 각각 68%와 53%의 감소율을 나타내었다. BAC 공정에서 생물분해 속도상수($k_{bio}$)와 반감기($t_{1/2}$)를 조사한 결과, 수온 $5^{\circ}C$에서 과산화수소 농도가 10 mg/L에서 300 mg/L로 증가할수록 $k_{bio}$$1.173min^{-1}$에서 $0.183min^{-1}$으로 감소하였고, $t_{1/2}$은 0.591 min에서 3.787 min으로 증가하였다. 수온 $25^{\circ}C$의 경우 $k_{bio}$$t_{1/2}$$1.510min^{-1}$에서 $0.498min^{-1}$ 및 0.459 min에서 1.392 min으로 나타나 수온 $5^{\circ}C$에 비해 수온이 $15^{\circ}C$$25^{\circ}C$로 상승할 경우 $k_{bio}$는 각각 1.1배~2.1배 및 1,3배~4.4배 정도 증가하였다. $O_3/BAC$ 공정을 운전 중인 정수장에서 peroxone 공정의 적용을 위해 과산화수소 투입을 고려할 경우, 후단의 BAC 공정에서 잔류 과산화수소를 효과적으로 제거 가능하였고, 고농도의 과산화수소 유출사고시에는 BAC 공정의 EBCT를 최대한 증가시켜 운전할 경우 수중의 과산화수소 농도를 최대한 저감시킬 수 있을 것으로 판단된다.

악취가스 제거를 위안 섬유상 담체를 적용한 바이오필터 운전조건에 관한 연구 (Study of Operation Condition of Biofilter Using Fibril-form Matrix for Odor Gas Removal)

  • 정귀택;이광연;변기영;이경민;선우창신;이우태;박찬영;김도형;차진명;장영선;박돈희
    • KSBB Journal
    • /
    • 제20권5호
    • /
    • pp.341-344
    • /
    • 2005
  • 섬유상 담체를 이용한 2단 소형 바이오필터를 이용한 악취가스 처리공정의 운전조건을 확립하기 위하여 BTX를 처리대상 물질로 바이오필터를 연속적으로 운전하여 섬유상 바이오필터 담체에 악취가스 처리용 미생물을 부착시킨 결과 우수한 부착된 생물막을 형성하여 높은 처리효율 $93\%$를 얻을 수 있었다. 또한, 악취 유입 농도 400 ppm 미만에서 체류시간 10 sec일 때 1단 반응기에서 $76\%$ 정도 제거율을 보이다가 2단 반응기에서 약 $93\%$의 제거율을 나타내었다. 그러나 체류시간이 15 sec 이상인 경우에는 제거효율이 $97\%$ 이상 유지되었다.

Simultaneous Biofiltration of H2S, NH3 and Toluene using an Inorganic/Polymeric Composite Carrier

  • Park, Byoung-Gi;Shin, Won-Sik;Chung, Jong-Shik
    • Environmental Engineering Research
    • /
    • 제13권1호
    • /
    • pp.19-27
    • /
    • 2008
  • Simultaneous removal of ternary gases of $NH_3$, $H_2S$ and toluene in a contaminated air stream was investigated over 180 days in a biofilter. A commercially available inorganic/polymeric composite chip with a large void volume (bed porosity > 0.80) was used as a microbial support. Multiple microorganisms including Nitrosomonas and Nitrobactor for nitrogen removal, Thiobacillus thioparus (ATCC 23645) for $H_2S$ removal and Pseudomonas aeruginosa (ATCC 15692), Pseudomonas putida (ATCC 17484) and Pseudomonas putida (ATCC 23973) for toluene removal were used simultaneously. The empty bed residence time (EBRT) ranged from 60 - 120 seconds and the inlet feed concentration was $0.0325\;g/m^3-0.0651\;g/m^3$ for $NH_3$, $0.0636\;g/m^3-0.141\;g/m^3$ for $H_2S$, and $0.0918\;g/m^3-0.383\;g/m^3$ for toluene, respectively. The observed removal efficiency was 2% - 98% for $NH_3$, 2% - 100% for $H^2S$, and 2% - 80% for toluene, respectively. Maximum elimination capacity was about $2.7\;g/m^3$/hr for $NH_3$, > $6.4\;g/m^3$/hr for $H_2S$ and $4.0\;g/m^3$/hr for toluene, respectively. The inorganic/polymeric composite carrier required 40 - 80 days of wetting time for biofilm formation due to the hydrophobic nature of the carrier. Once the surface of the carrier was completely wetted, the microbial activity became stable. During the long-term operation, pressure drop was negligible because the void volume of the carrier was two times higher than the conventional packing materials.

생물학적 처리기술을 이용한 대기오염 제어 (Biotreatment Technologies for Air Pollution Control)

  • 원양수
    • 청정기술
    • /
    • 제13권1호
    • /
    • pp.1-15
    • /
    • 2007
  • 미생물을 이용하여 생물분해 가능한 휘발성유기물질과 악취물질을 처리하는 생물학적 대기오염처리 기술은 기존의 일반적으로 사용되고 있는 방법에 비해 상대적으로 최근에 개발된 방법이다. 생물학적 방법에 의한 대기오염물질 처리는 기존의 처리방법을 대체할 수 있는 방법으로 각광을 받고 있다. 생물학적 처리방법은 유기화합물 또는 악취가 포함된 저농도 고유량의 공기를 처리하는데 효과적이다. 생물학적 처리방법은 기존의 소각 또는 흡착 방법에 비해 여러 장점을 가지고 있다. 주요 장점으로 처리비용이 저렴하고, 2차 오염물질이 발생되지 않으며, 화학물질이 사용되지 않고, 에너지 사용이 적으며, 상온에서의 운전 등이다. 생물학적 방법중 생물여과법, 생물살수여과법, 생물세정법 세가지 방법이 널리 이용되고 있다. 이들 방법중 생물여과법이 가장 많이 이용되고 있으나 실제 적용에 있어 여러 제약이 있어 이를 해결하기 위한 생물학적 방법들에 대한 연구가 수년 전부터 수행되어 왔다. 생물살수여과법은 생물여과법에 비해 다소 복잡하나 난분해성 물질이나 분해과정에서 산이 생성되는 경우 효과적으로 이용될 수 있다. 본 연구에서는 대기오염제어를 위한 생물여과법, 생물살수여과법, 생물세정법의 기본원리와 이론 및 실용적 내용을 다루었다. 특히 생물학적 방법들의 운전 인자와 성능에 미치는 영향인자 및 비용평가 등에 대해 조사 분석하였으며, 생물살수여과법에 대해서는 좀 더 집중적으로 고찰하였다.

  • PDF

Peat가 충진된 고정층 생물반응기에서 온도 투입농도가 휘발성 유기화합물의 분해에 미치는 영향 (Effects of Temperature and lncoming Concentrations on the Removal of Volatile Organic Compounds in a Biofilter Packed with Peat)

  • 윤인길;박창호
    • KSBB Journal
    • /
    • 제16권3호
    • /
    • pp.281-285
    • /
    • 2001
  • 실험실 규모의 생불여과기에 peat들 패깅하여 휘발성 유기 화합물 (isoprene, dimethyl 야dfide, 블로르포륨, 벤젠, 삼염화에 헬렌, 툴루엔. m-자일렌. 0-자일렌, 스타이렌)의 분해 정도를 가스 처l류시간을 3.2분으로 하여 80일간 측정하였다. 34일의 적응기간이 지난 후 $65~83 g/m^3$로 유입되는 VOC의 분해율 이 $25^{circ}C$액서는 93%이었으나 $45^{circ}C$에서는 여 보다 낮은 73%이었다. $25^{circ}C$에서 77일 후 도달한 최고 세포농도논 초기 농도 의 약 100배인 $1.12\times10^8$세포/g 이었다, 그러나 $45^{circ}C$C에서 도 달한 최고 세포농도는 이의 10분의 1에 불과하였다. m-자이렌과 툴루엔의 분해율 (91 %)에 비하여 벤젠의 분해율 (86%)이 낮았다. 생불여과기의 패정된 부분을 네 구간으로 나누었 을 때 가스가 유입되는 저음 사분회 일에 해당하는 부분에서 VOC의 분해율이 60%에 도달하였다 본 연구는 휘발생 유해 물질 혼합처l를 생붙여과법에 의해 처리하는 것이 가능함을 보여주었고 이러한 기술을 현장에서 배출되는 대기유해풀 칠의 효율적 저감에 적용하면 대기보첸에 기여할 수 있을 것이다.

  • PDF

혐기-호기 상향류 필터 공정에서 양식배출수의 질산화 및 탈질 연구 (Nitrification and Denitrification of Land-based Fish Farm Wastewater using an Anaerobic-Aerobic Upflow Biological Aerated Filter)

  • 박노백;이현영;김성민;이준상
    • 한국수산과학회지
    • /
    • 제47권5호
    • /
    • pp.622-629
    • /
    • 2014
  • This study induced biological denitrification and nitrification via a biofiltration process with the view of removing nitrogen from land-based fish farm effluent. To achieve this, we operated an aquaculture nitrogen-removal system that includes a denitrification and nitrification reactor [working volume 40 L, flow rate 64.8 L, HRT (hydraulic retention time) 14.8 h, HRT considering recycling of NOx 7.4 h]. In the continuous process, the nitrification rate of ammonium nitrogen exceeded 90% at a steady state and the denitrification efficiency exceeded 80% with recycling to a pre-anoxic reactor. In addition, the pH in the final effluent was lower with a low influent water alkalinity averaging 100 mg/L (as $CaCO_3$). For effective denitrification reactions, carbon must be supplied via particulate organic matter (POM) hydrolysis because of the low C/N (carbon/nitrogen) ratio in the water.

활성탄과 생물여과 공정에서의 Chloral hydrate 제거 특성 (Removal Characteristics of Chloral Hydrate by Activated Carbons and Biofiltration)

  • 배상대;손희종;정철우
    • 대한환경공학회지
    • /
    • 제30권2호
    • /
    • pp.218-224
    • /
    • 2008
  • 본 연구에서는 석탄계, 야자계, 목탄계 활성탄과 흡착능이 없는 안트라사이트를 이용하여 클로랄하이드레이트에 대한 흡착 및 생물분해 특성을 평가하였다. 활성탄 공정에서 클로랄하이드레이트의 제거기작은 운전초기에는 흡착이 높은 비중을 차지하나 부착미생물의 활성이 증진되면서 부착미생물에 의한 생분해와 흡착에 의해 제거되었으며, 클로랄하이드레이트는 생분해능이 큰 물질들로 조사되었다. 입상활성탄 재질별 클로랄하이드레이트의 제거 특성은 석탄계와 야자계 활성탄에서 제거율이 높았고, 목탄계는 상대적으로 낮은 제거능을 보였으며, 안트라사이트 biofilter에서 가장 낮은 제거능을 보였다. 활성탄 재질별 부착 미생물의 생체량과 활성도는 석탄계가 가장 높았고, 야자계, 목탄계, 안트라사이트 순으로 나타났으며, 수온 변화에 따른 클로랄하이드레이트의 제거 특성은 수온이 10$^{\circ}C$ 이하로 저하될 경우 부착 bacteria의 생체량과 활성도 감소로 제거율이 감소하였다. 안트라사이트를 이용한 생물여과 공정은 수온의 변화에 아주 민감하게 변하는 양상을 나타내었으며, 이는 부착 bacteria에 의한 직접적인 생물분해가 주 제거 메카니즘이기 때문인 것으로 나타났다. 클로랄하이드레이트의 제거시 유입농도가 높은 경우에는 수온의 영향이 매우 중요하며, 흡착능이 소진된 활성탄이나 흡착능이 없는 여재를 사용한 생물여과 공정에서는 수온이 낮은 동절기에는 클로랄하이드레이트의 유출 가능성이 있었다.

MEK 제거를 위한 바이오필터용 담체의 선택 (Selection of Biofilter Support for Removing MEK)

  • 정귀택;이광연;이경민;선우창신;이우태;정승호;차진명;장영선;박돈희
    • KSBB Journal
    • /
    • 제21권1호
    • /
    • pp.34-41
    • /
    • 2006
  • 본 악취제거용 바이오필터에 필요한 담체에 대하여 실험한 결과 다음과 같은 결론을 얻었다. 합성악취가스의 조성이 MEK 250 ppm을 바이오필터에 통과시켰을 때, 폴리프로필렌 섬유상은 $586.6g-MEK/m^3\;hr$로 실험담체 중에서 최고 제거량을 나타내었다. 폴리우레탄 담체는 $359.7g-MEK/m^3\;hr$을 제거용량을 나타내었다. 화산석 담체의 제거량은 $56.2g-MEK/m^3\;hr$으로 평가되었다. 본 연구에서 사용한 담체 중에서 MEK 제거에 사용될 수 있는 최적의 담체로는 폴리플로필렌 섬유상 담체로 평가되었다.