전기적 임피던스 방법을 통한 hand-held 타입의 심박출량 모니터링 시스템 개발 및 검증 (Development and Verification of a Hand-held Typed Monitoring System for Cardiac Output Measurement using Electrical Impedance Technique)

  • 서광석;심명헌;김민용;윤찬솔;정주홍;박성빈;윤형로
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1932-1938
    • /
    • 2012
  • The impedance cardiogram has been proposed as a non-invasive, continuous, operator independent, and cost-effective method for cardiac output monitoring. However, it can not be completely considered as non-restrictive method because of attached spot and band type electrodes. Therefore, we developed a improved convenient hand-held typed measurement system for cardiac output by electrical impedance technique. 80 subjects from Yonsei University and the surrounding areas, participated. All subjects measured stroke volume and cardiac output through Physioflow and developed system. To verify the developed system, statistical methods such as correlation, Wilcoxon signed ranks test, and the Bland-Altman analysis were used. The proposed system showed significant correlation in both male and female stroke volume(r=0.715, r=0.704) and cardiac output(r=0.826; r=0.804). From these results, it can be concluded that stroke volume and cardiac output could be improved convenient measurement using the both hands without the help of a specialist.

건식전극을 이용한 4 전극형 생체임피던스 모델 특성 연구 (A Study on the Characteristics of Four Electrode Bioimpedance Model using Dry Electrode)

  • 조영창;정종혁;윤정오;김민수
    • 전기전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.1122-1127
    • /
    • 2019
  • 본 연구에서는 인체의 생체임피던스는 임상 및 생물학적 조직의 병적 및 생리적 상태를 모니터링 하여 많은 정보를 획득 가능하다. 생체임피던측정용 4 전극법시스템은 2개의 전극은 생체의 전위차를 측정하였고, 다른 두 전극은 전류를 흘러주는 전극으로 사용하였다. 새롭게 개발된 건식 Gold 전극은 1 Hz에서 50 kHz 까지 임피던스를 측정하였으며, 재현성 있는 결과를 얻었다. 건식전극의 임피던스 측정값을 검증하기 위해서 생체전극피부등가회로를 이용하여 피팅을 실시하였고 모델링을 통해서 실효성을 증명하였다. 고정 전극형태는 측정 시 부착되는 전극의 위치가 일정하므로 안정적인 측정값을 얻을 수 있어서 오류를 최소화할 수 있다.

방사선 피폭선량에 대한 생체 조직의 임피던스 변화 (Impedance Changes of Living Tissue During Radiation Exposure Dose)

  • 길상형;이무석;남지호;이영화;김군도;이종규
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.202-207
    • /
    • 2013
  • 생체 조직의 전기 신호는 살아 있는 조직과 관련된 많은 정보를 포함하고 있으며, 생체 조직에 생물학적 변화가 있으면 고유의 전기적 특성이 변화한다. Impedance/Gain-phase analyzer로 1 KHz에서 1 KHz까지 주파수 대역을 설정한 다음 교류 주파수를 인가하며 돼지안심 조직의 임피던스 특성을 방사선 피폭선량에 따라 변화가 있는지 알아보고자 하였다. 임피던스 크기는 주파수에 비례하여 감소하였으며, 상관계수(r)가 -0.96으로 높은 음의 상관관계를 보였다. 위상차 변화는 거의 없었으며 조직은 저항성을 나타내었다. 측정값은 변동계수가 ${\pm}5$%이내로 재현성이 있음을 알 수 있었고, 측정 시간 경과에 따른 임피던스 크기와 위상차 변화는 유의적인 차이가 없었다.(p>0.05) 방사선 피폭 시 임피던스 변화는 대조군과 비교했을 때 1 Gy, 2 Gy, 4 Gy 피폭 선량에서는 임피던스 크기는 감소하였으나, 유의적인 차이는 없었다.(p>0.05) 그러나 10 Gy 피폭 선량에서는 임피던스 크기 감소가 유의적으로 나타났다.(p<0.05) 방사선 피폭선량이 증가하여도 위상차 변화는 거의 없었으며, 대조군과 비교했을 때 1 Gy, 2 Gy, 4 Gy, 10 Gy 모두 유의적인 차이가 없었다.(p>0.05) 본 연구를 통해 생체 조직의 전기적 특성을 이해 할 수 있었고, 방사선 피폭선량에 따른 임피던스 변화를 측정하여 방사선이 인체에 미치는 영향을 직접 평가 할 수 있는 가능성을 확인 할 수 있었다.

광전 방식에 의한 피하 지방층의 비만도 측정에 관한 연구 (A Study on The Fat Measurement at Subcutaneous Adipose by Optical and Electrical Method)

  • 오세용;이영우
    • 한국정보통신학회논문지
    • /
    • 제12권6호
    • /
    • pp.1070-1074
    • /
    • 2008
  • 광학적 방식은 백색광 LED광원을, 전기적 방식은 BIA(Bio-electrical Impedance)방식을 이용하여 동시에 측정할 수 있는 광전기적 지방측정에 관한 상관식을 유도하였다. 실험을 통해서 BIA 방식의 경우 5V 및 50kHz의 입력 교류 신호에 대해 6도의 위상차와 2.7V의 전압 강하를 확인하였다. 광학적 방식의 경우 이두박근, 허벅지, 삼두박근의 순으로 광강도가 높아지는 것을 확인하였다. 측정된 광전 방식의 값은 상관식에 의해서 20%의 퍼센트 비만도를 얻었다.

나피온 폴리머를 이용한 금 전극의 표면 개질 및 이의 삼투압 측정용 임피던스 센서 응용 (Surface Modification of Gold Electrode Using Nafion Polymer and Its Application as an Impedance Sensor for Measuring Osmotic Pressure)

  • 길민식;김민재;윤조희;장진우;이경균;최봉길
    • 공업화학
    • /
    • 제34권1호
    • /
    • pp.9-14
    • /
    • 2023
  • 본 논문에서는 용액의 이온 농도 측정이 가능한 나피온 폴리머(Nafion polymer) 코팅 기반 2상 금 전극의 임피던스(Impedance) 센서를 개발하였다. 스퍼터링(Sputtering) 공정을 통해서 제작된 금 전극의 표면을 나피온 폴리머를 사용하여 표면 개질 하였다. 상기 제작된 전극은 분극 현상 제어가 가능하여 전기화학적 신호를 안정적으로 측정할 수 있도록 하였다. 분광학과 전자주사현미경 관찰을 통하여 박막의 나피온 폴리머 코팅을 확인하였다. 나피온 코팅이 된 전극은 기존 금 전극에 비해 안정적인 임피던스 신호를 보여 주었으며, 표준 염화나트륨(NaCl) 용액 사용 시 임피던스 센서의 신뢰성 높은 검정 곡선(R2 = 0.983)을 나타내었다. 또한, 임피던스 센서는 상용화 전도도 장치와 인공 눈물의 이온 농도 측정 비교 실험을 진행하였으며, 유사한 결과값을 확인하였다.

생체 신호 측정을 위한 섬유전극의 형태에 따른 전기적 특성 분석 및 비교 (Analysis and comparison of textile electrode's electrical characteristics in several shapes for biopotential signals)

  • 이영재;이강휘;이정환;강다혜;조하경;조현승;이주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.371-372
    • /
    • 2008
  • Many kinds of electrodes have been developed in various forms and shapes for measurement of bio potential signal. Textile electrode has benefit of collect long tenn data monitoring because of it is non-consciousness, convenient and do not occur skin irritation. However, It is very difficult to acquire available data due to high impedance of electrode and unstable skin-electrode contact which generate motion artifact. Also snap button which usually used as mediator between textile and measurement device cause change of electrical characteristics. In this paper, we inflated textile electrode to stabilize contact and add conductive silver paste between textile and snap button to improve conductance. To compare the performance of two methods, flat or inflated and add conductive paste or not, four types of electrodes are tested on each impedance and SNR by ECG measurement. In result, the first type electrode which flat and non-conductive paste showed the worst performance and the last type electrode which is inflated shape and contain conductive paste show the best performance.

  • PDF

자세에 따른 생체임피던스 변화와 혈압 특성 분석 (Analysis of Bioimpedance Change and the Characteristics of Blood Pressure according to Posture)

  • 조영창;김민수
    • 한국산업정보학회논문지
    • /
    • 제19권5호
    • /
    • pp.25-31
    • /
    • 2014
  • 생체전기 임피던스 해석은 체 성분 측정에 있어 비침습적이며, 비용이 적게 들고 안전성과 재현성이 우수하여 체 성분의 변화를 평가하기 위해 널리 사용되고 있는 방법이다. 본 연구에서는 자세에 따른 생체임피던스와 혈압차이에 대해 연구하였으며, 피 실험자를 대상으로 생체전기 임피던스 측정시스템을 통한 저항 및 리액턴스의 실시간 측정 실험과 등가모델을 통한 모의실험 그리고 자세 변화에 대한 혈압 차이를 비교하는 실험을 실시하였다. 생체임피던스는 다중 주파수(1 kHz, 10 kHz, 20 kHz, 50 kHz, 70 kHz, 100 kHz)에서 4분간 측정하였다. 실험결과, 선 자세, 앉은 자세, 누운 자세 순으로 몸의 임피던스는 저항과 리액턴스의 변화로 인해 증가하는 것으로 나타났다. 특히, 누운 자세에서의 저항은 50 kHz에서 앉은 자세에서의 저항보다 평균 16.49% 높았으며, 누운 자세에서의 리액턴스는 5 kHz일 때에 앉은 자세보다 평균 26.05% 높았다. 혈압의 경우에는 다른 자세에 비해 선 자세에서의 평균 최고치($125.14{\pm}12.30$) 및 평균 최저치($75.57{\pm}10.31$) 혈압이 높게 나타났다. 본 연구의 생체임피던스 및 혈압 차이에 관한 연구는 급성 질환, 고도 비만, 신체 기형 등의 연구에 활용될 수 있을 것으로 사료된다.

휴대용 소형임피던스 측정시스템을 이용한 다중주파수의 생체임피던스 해석 (Bioelectrical Impedance Analysis of Multi-frequency using Portable Small Impedance Measuring System)

  • 김민수;조영창
    • 한국융합학회논문지
    • /
    • 제8권2호
    • /
    • pp.121-126
    • /
    • 2017
  • 본 연구에서는 피부 등가모델을 통한 세포 내액과 세포 외액 성분의 생체임피던스 특성을 파악하기 위해 개발한 휴대용 소형 임피던스 측정시스템을 이용하여 4 전극법에 의한 비 침습 방식으로 다양한 주파수 대역에서 전신의 생체전기 임피던스를 측정실험을 수행하였다. 측정은 10명의 남성 피 실험자(평균 나이 $24{\pm}3.0$세, (BMI) $20.3kg/m^2$)를 대상으로 4주간 실시하였으며, 생체임피던스 다중주파수(1 kHz, 5 kHz, 50 kHz, 70 kHz, 100 kHz, 500 kHz)대역에서 측정하였다. 실험결과, 저주파 대역인 1 kHz 대역에서 임피던스가 가장 높게 측정되었고, 고주파 대역인 500 MHz에서 임피던스가 가장 낮게 측정되었다. 특히 50 kHz 대역이상에서 임피던스가 급속히 낮아짐을 실험을 통해서 확인하였다. 또한, 피부 등가회로모델을 통한 세포 내액과 세포 외액의 임피던스 특성을 파악하는 모의실험에서도 본 연구의 생체임피던스 측정시스템의 측정값과 유사한 특성이 얻어짐을 확인할 수 있었다.

색채 환경 기반의 인체 반응 정보 측정 시스템 (A Measurement System for Color Environment-based Human Body Reaction)

  • 김지언;정창원;주수종
    • 인터넷정보학회논문지
    • /
    • 제17권2호
    • /
    • pp.59-65
    • /
    • 2016
  • 색채 환경에 따라 인지반응의 상관관계를 분석한 결과가 다양한 산업분야에 적용되고 있다. 특히, 의학 분야에서 색채 환경기반 생체신호를 수집하여 환자 상태의 파악과 치료 그리고 뇌활동의 규명에 관련된 연구가 활발하게 진행되고 있다. 그러나 기존 연구들은 색채조명 또는 LED를 이용한 색채 환경을 구축하여 다양한 실험을 진행하고 있으나 다른 광원에 노출 되어 심리적인 영향을 주는 문제점을 갖고 있다. 따라서, 본 논문에서 제안하는 시스템은 HMD(Head-Mounted-Display)를 이용하여 피험자에게 완벽한 색채 환경조건을 제공하고자 한다. 그리고 인체반응정도 측정을 위해 기억력-주의력 테스트하는 동안 BMS(Bio-Medical-System)으로 생체정보를 수집하여 색채별 인체반응정도 측정뿐만 아니라 심리적인 변화에 대한 상관관계를 확인할 수 있는 시스템을 제안한다. 제안한 시스템을 통하여 수집하는 생체정보는 심전도(ECG), 호흡(Respiration), 산소포화도(SpO2), 임피던스(Bio-Impedance), 혈압(Blood-Pressure) 이며 데이터베이스에 저장한다. 이와함께, 인체의 인지반응을 측정하기위해 기억력-주의력 테스트는 앱으로 구현하여 색채 조건별 인지반응 정보를 측정하고 결과를 확인 할 수 있다. 제안한 시스템을 통하여 수집된 인체반응정보를 활용하여 생리학적 정보의 정량화하는 연구를 진행할 수 있으며, 색채 환경과 생리학적 정보의 상관관계를 분석하여 의학적 진단 및 치료에 응용이 될 것으로 기대한다. 향후 연구로 구축한 시스템을 통해 수집된 데이터를 분석 및 시각화 기능을 추가하고, 치매 질환의 예측 및 치료를 위한 시스템으로 확장하여 재활프로그램으로서의 유효성을 평가하고자 한다.

디지털 임피던스 영상 시스템의 설계 및 구현 (Design and Implementation of Digital Electrical Impedance Tomography System)

  • 오동인;백상민;이재상;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권4호
    • /
    • pp.269-275
    • /
    • 2004
  • 인체내부의 각 조직은 서로 다른 저항률(resistivity)분포를 가지며, 조직의 생리학적, 기능적 변화에 따라 임피던스가 변화한다. 본 논문에서는 주로 기능적 영상을 위한 임피던스 단층촬영 (EIT, electrical impedance tomography) 시스템의 설계와 구현 결과를 기술한다. EIT 시스템은 인체의 표면에 부착한 전극을 통해 전류를 주입하고 이로 인해 유기되는 전압을 측정하여, 내부 임피던스의 단층영상을 복원하는 기술이다. EIT 시스템의 개발에 있어서는 영상복원의 난해함과 아울러 측정시스템의 낮은 정확도가 기술적인 문제가 되고 있다. 본 논문은 기존 EIT 시스템의 문제점을 파악하고 디지털 기술을 이용하여 보다 정확도가 높고 안정된 시스템을 설계 및 제작하였다. 크기와 주파수 및 파형의 변화 가능한 50KHz의 정현파 전류를 인체에 주입하기 위해 필요한 정밀 정전류원을 설계하여 제작한 결과, 출력 파형의 고조파 왜곡(THD, total harmonic distortion)이 0.0029%이고 진폭 안정도가 0.022%인 전류를 출력 할 수 있었다. 또한, 여러개의 정전류원을 사용함으로써 채 널간 오차를 유발하던 기존의 시스템을 변경하여, 하나의 전류원에서 만들어진 전류를 각 채널로 스위칭하여 공급함으로써 이로 인한 오차를 줄였다. 주입전류에 의해 유기된 전압의 정밀한 측정을 위해 높은 정밀도를 갖는 전압측정기가 필요하므로 차동증폭기, 고속 ADC및 FPGA(field programmable gate array)를 사용한 디지털 위상감응복조기 (phase-sensitive demodulator )를 제작하였다. 이때 병렬 처리를 가능하게 하여 모든 전극 채널에서 동시에 측정을 수행 할 수 있도록 하였으며, 제작된 전압측정기의 SNR(signal-to-noise ratio)은 90dB 이다. 이러한 EIT 시스템을 사용하여 배경의 전해질 용액에 비해 두 배의 저항률을 가지는 물체(바나나)에 대한 기초적인 영상복원 실험을 수행하였다. 본 시스템은 16채널로 제작되었으나 전체를 모듈형으로 설계하여 쉽게 채널의 수를 늘릴 수 있는 장점을 가지고 있어서 향후 64채널 이상의 디지털 EIT시스템을 제작할 계획이며, 인체 내부의 임피던스 분포를 3차원적 으로 영상화하는 연구를 수행 할 예정이다.