• Title/Summary/Keyword: Bio-Signal Interface

Search Result 39, Processing Time 0.025 seconds

Flexible biosensors based on field-effect transistors and multi-electrode arrays: a review

  • Kim, Ju-Hwan;Park, Je-Won;Han, Dong-Jun;Park, Dong-Wook
    • Journal of Semiconductor Engineering
    • /
    • v.1 no.3
    • /
    • pp.88-98
    • /
    • 2020
  • As biosensors are widely used in the medical field, flexible devices compatible with live animals have aroused great interest. Especially, significant research has been carried out to develop implantable or skin-attachable devices for real-time bio-signal sensing. From the device point of view, various biosensor types such as field-effect transistors (FETs) and multi-electrode arrays (MEAs) have been reported as diverse sensing strategies. In particular, the flexible FETs and MEAs allow semiconductor engineering to expand its application, which had been impossible with stiff devices and materials. This review summarizes the state-of-the-art research on flexible FET and MEA biosensors focusing on their materials, structures, sensing targets, and methods.

Human-Computer Interface Based on Bio-Signal (생체신호 기반 사용자 인터페이스 기술)

  • Kim, J.S.;Kim, H.K.;Jeong, H.;Kim, K.H.;Im, S.H.;Son, W.H.
    • Electronics and Telecommunications Trends
    • /
    • v.20 no.4 s.94
    • /
    • pp.67-81
    • /
    • 2005
  • 생체신호 기반 인터페이스 기술이란 근전도 및 뇌파와 같은 인위적으로 발생 가능한 생체 신호를 이용하여, 노약자나 장애인이 컴퓨터를 이용하는 데 있어서의 인터페이스(Human-Computer Interface)로 사용하거나 휠체어 등의 재활기기 구동 제어를 위한 명령어를 생성하기 위한 기술을 의미한다. 생체신호 기반 인터페이스는 센서를 몸에 부착하여 사용하며 사용자의 의도에 의해 자연스럽게 생성된 생체신호를 이용하기 때문에 가상현실, 착용형 컴퓨터나 지체 장애인용 인터페이스로 활용될 수 있을 것으로 기대된다. 본 논문에서는 이러한 생체신호 기반의 인터페이스에 관한 국내외 기술 동향과 현재 개발중인 HCI 시스템에 대한 개요에 대해 논하고자한다.

Development of Eye-Tracking System Using Dual Machine Learning Structure (이중 기계학습 구조를 이용한 안구이동추적 기술개발)

  • Gang, Gyeong Woo;Min, Chul Hong;Kim, Tae Seon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1111-1116
    • /
    • 2017
  • In this paper, we developed bio-signal based eye tracking system using electrooculogram (EOG) and electromyogram (EMG) which measured simultaneously from same electrodes. In this system, eye gazing position can be estimated using EOG signal and we can use EMG signal at the same time for additional command control interface. For EOG signal processing, PLA algorithms are applied to reduce processing complexity but still it can guarantee less than 0.2 seconds of reaction delay time. Also, we developed dual machine learning structure and it showed robust and enhanced tracking performances. Compare to conventional EOG based eye tracking system, developed system requires relatively light hardware system specification with only two skin contact electrodes on both sides of temples and it has advantages on application to mobile equipments or wearable devices. Developed system can provide a different UX for consumers and especially it would be helpful to disabled persons with application to orthotics for those of quadriplegia or communication tools for those of intellectual disabilities.

Impact of Upper Limb Joint Fluid Variation on Inflammatory Diseases Diagnosis

  • Hari, Krishnan G.;Ananda, Natarajan R.;Nanda, Anima
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2114-2117
    • /
    • 2014
  • Joint pain is generally a common disorder not only for the old aged people but also for the immunocompromised patients. The present proposed study reveals the presence of inflammatory diseases in joint generally diagnosed by removing synovial fluid and changes in the volume and composition are examined for the presence of WBC and crystals. This study implement a non-invasive approach to identify the changes in joint fluid by measuring the changes in electrical property of the synovial tissue under the influence of electrical current signal with frequency range between 100 kHz to 300 kHz. The response of tissue for the current signal was measured in terms of potential drop across the tissue. The hardware system design consists of input and output sections. The input section which applies current signal to upper limb joint region is made of ICL8038 function generator IC with amplifier and voltage to current converter. The output section picks voltage variation using metal surface electrode, amplifier, ADC, PIC microcontroller and LCD interface. 100 patient inclusive of normal and disease affected patients where examined for upper limb synovial fluid variation and inflammatory diseases were identified.

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Arduino-based power control system implemented by the MyndPlay (MyndPlay를 이용한 Arduino기반의 전원제어시스템 구현)

  • Kim, Byeongsu;Kim, Seungjin;Kim, Taehyung;Baek, Dongin;Shin, Jaehwan;An, Jeong-Eun;Jeong, Deok-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.924-926
    • /
    • 2015
  • In this paper, we use the interface, which many countries concentrates research of Brain - Computer Interface with the device and MyndPlay based on the IoT intelligent Arduino. Finally we will make the Brain - Computer Connection environment, the purpose of Brain - Computer Interface. Recognizes the EEG of a person who wearing the equipment, analyze, classify, and we did a research to design an intelligent thing to suit user's condition. In addition, we use the XBee, and Bluetooth to communicate to other devices, such as smart phone. In conclusion, this paper check users current status via brain waves, and it allows to control the power and other objects by using the EEG(Electroencephalography).

  • PDF

A Study of the Development of 24ch. Meridian Electric - Potential Measuring System (24 채널 경락 전위 측정 시스템 개발에 관한 연구)

  • Lee, Woo-Cheol;SaKong, Sug-Chin
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.1-6
    • /
    • 2005
  • The 24 channel meridian electric-potential measuring System consists of a main cpu module, bio-signal analog module, interface module, power module, personal computer. The graphic user interface program conveniently allows user to setup, calibrate, measure, store, and control the meridian electric-potential measuring system. This system and program will continually be evolved using a database of clinically correlated meridian electric-potential. A variety of system configurations gives it the ability to make a user-favorable environment for measuring.

Interface of Tele-Task Operation for Automated Cultivation of Watermelon in Greenhouse

  • Kim, S.C.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.28 no.6
    • /
    • pp.511-516
    • /
    • 2003
  • Computer vision technology has been utilized as one of the most powerful tools to automate various agricultural operations. Though it has demonstrated successful results in various applications, the current status of technology is still for behind the human's capability typically for the unstructured and variable task environment. In this paper, a man-machine interactive hybrid decision-making system which utilized a concept of tole-operation was proposed to overcome limitations of computer image processing and cognitive capability. Tasks of greenhouse watermelon cultivation such as pruning, watering, pesticide application, and harvest require identification of target object. Identifying water-melons including position data from the field image is very difficult because of the ambiguity among stems, leaves, shades. and fruits, especially when watermelon is covered partly by leaves or stems. Watermelon identification from the cultivation field image transmitted by wireless was selected to realize the proposed concept. The system was designed such that operator(farmer), computer, and machinery share their roles utilizing their maximum merits to accomplish given tasks successfully. And the developed system was composed of the image monitoring and task control module, wireless remote image acquisition and data transmission module, and man-machine interface module. Once task was selected from the task control and monitoring module, the analog signal of the color image of the field was captured and transmitted to the host computer using R.F. module by wireless. Operator communicated with computer through touch screen interface. And then a sequence of algorithms to identify the location and size of the watermelon was performed based on the local image processing. And the system showed practical and feasible way of automation for the volatile bio-production process.

Research of Real-Time Emotion Recognition Interface Using Multiple Physiological Signals of EEG and ECG (뇌파 및 심전도 복합 생체신호를 이용한 실시간 감정인식 인터페이스 연구)

  • Shin, Dong-Min;Shin, Dong-Il;Shin, Dong-Kyoo
    • Journal of Korea Game Society
    • /
    • v.15 no.2
    • /
    • pp.105-114
    • /
    • 2015
  • We propose a real time user interface that utilizes emotion recognition by physiological signals. To improve the problem that was low accuracy of emotion recognition through the traditional EEG(ElectroEncephaloGram), We developed a physiological signals-based emotion recognition system mixing relative power spectrum values of theta/alpha/beta/gamma EEG waves and autonomic nerve signal ratio of ECG (ElectroCardioGram). We propose both a data map and weight value modification algorithm to recognize six emotions of happy, fear, sad, joy, anger, and hatred. The datamap that stores the user-specific probability value is created and the algorithm updates the weighting to improve the accuracy of emotion recognition corresponding to each EEG channel. Also, as we compared the results of the EEG/ECG bio-singal complex data and single data consisting of EEG, the accuracy went up 23.77%. The proposed interface system with high accuracy will be utillized as a useful interface for controlling the game spaces and smart spaces.

Signl processing method and diagnostic algorithm for arterial oxygen-saturation measument (산소포화도 측정을 위한 신호처리방법 및 계산 알고리즘)

  • 김수진;황돈연;전계진;이종연;정성규;윤길원
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.6
    • /
    • pp.452-456
    • /
    • 2000
  • A measurement unit and signal processing algorithm have been developed for predicting arterial oxygen saturation noninvasively. The measurement set-up was composed of a probe including light source and photodetector, optical signal processing section, LED driving circuit, PC interface software for data acquisition and data processing software. Light from the LED's was irradiated onto the finger nail bed and transmitted light was measured at different wavelengths. An effective baseline correction method was developed and measured data were analyzed by using various data processing methods and prediction algOlithms. For performance evaluation, a pulse oximeter simulator (Bio- Tek Instrument Inc.) was used as reference. The best performance in terms of the correlation coefficient and the standard deviation was obtained under the following conditions; when the arterial signals were computed in terms of area rather than peak-valley difference, and when the algorithm calculating by $In(I_p/I_v)/I_{avr}$ value for pulsation waveform was used. In in vivo test, prediction was improved when the developed baseline correction method was used. In addition, wavelengths of 660 nm and 940 nm provided better linearity and precision than wavelengths of 660 nm and 805 nm. 05 nm.

  • PDF