• Title/Summary/Keyword: Bio Signal Processing

Search Result 102, Processing Time 0.037 seconds

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Removing the Motion Artifacts in the Pulse Signal Detected from the PFS Using the Quasi-periodicity (유사 주기성을 이용한 PFS 펄스 신호의 동잡음 제거)

  • Lee, Han-Wook;Chun, Joong-Chang;Jeong, Won-Geun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.591-598
    • /
    • 2016
  • For the mobile healthcare environment, it is important to measure the exact biomedical signals in real time, and another key point is to design mobile healthcare devices with low power consumption. In this paper, we propose a method in which the piezo film sensor(PFS), having a low power characteristic, is used to measure the pulse signal synchronized with the heart rate from the radial artery. The critical issue in the bio-signal processing is the existence of the motion artifacts. To dissolve this problem, we have applied the periodic moving average filter using the quasi-periodicity of the pulse signal in addition to the conventional method of the adaptive filtering using the reference signal. Results of simulation and experiments are presented to confirm that the quasi-periodicity of the PFS signal can be used to eliminate completely the motion artifacts which still appears after the adaptive filtering.

Resistive E-band Textile Strain Sensor Signal Processing and Analysis Using Programming Noise Filtering Methods (프로그래밍 노이즈 필터링 방법에 의한 저항 방식 E-밴드 텍스타일 스트레인 센서 신호해석)

  • Kim, Seung-Jeon;Kim, Sang-Un;Kim, Joo-yong
    • Science of Emotion and Sensibility
    • /
    • v.25 no.1
    • /
    • pp.67-78
    • /
    • 2022
  • Interest in bio-signal monitoring of wearable devices is increasing significantly as the next generation needs to develop new devices to dominate the global market of the information and communication technology industry. Accordingly, this research developed a resistive textile strain sensor through a wetting process in a single-wall carbon nanotube dispersion solution using an E-Band with low hysteresis. To measure the resistance signal in the E-Band to which electrical conductivity is applied, a universal material tester, an Arduino, and LCR meters that are microcontroller units were used to measure the resistance change according to the tensile change. To effectively handle various noises generated due to the characteristics of the fabric textile strain sensor, the filter performance of the sensor was evaluated using the moving average filter, Savitsky-Golay filter, and intermediate filters of signal processing. As a result, the reliability of the filtering result of the moving average filter was at least 89.82% with a maximum of 97.87%, and moving average filtering was suitable as the noise filtering method of the textile strain sensor.

Development of a Real-Time Soil Moisture Meter using Oscillation Frequency Shift Method

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seoung-Seok;Noh, Sang-Ha
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.63-68
    • /
    • 2001
  • The objective of this study was to develop a real-time soil moisture meter using RF impedance. The impedance suchas capacitance and resistance (or conductance) was analyzed using parallel cylinder type capacitance probe(C-probe) and Q-meter (HP4342). The capacitance and conductance of soil increased as volumetric water content increased. The 5 MHz of modified Colpitts type crystal oscillator was designed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model was proposed to describe the relationship between RF impedance and volumetric water content. The prototype real time moisture meter consisted of the C-probe, sample container, oscillator, frequency counter and related signal processing units. The calibration equation for measurement of volumetric moisture content of soil was developed and validated. The correlation coefficient and root mean square error between measured volumetric water content by oven method and predicted values by prototype moisture meter for unknown soil samples were 0.984 and 0.032$cm^3$$cm\^3$, respectively.

  • PDF

DSP Embeded Hardware for Non-contact Bio-radar Heart and Respiration Rate Monitoring System (DSP를 이용한 비 접촉식 도플러 바이오 레이더 생체신호 모니터링 시스템 임베디드 하드웨어의 개발)

  • Kim, Jin-Seung;Jang, Byung-Jun;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.97-104
    • /
    • 2010
  • In this paper, we provide an embedded type non-contact bio-radar heart and respiration rate monitoring system. We implemented the rate finding algorithm into the embedded system. The high-speed and reliable real-time signal processor is then tested. To avoid null-point data loss problem, we applied quadrature demodulation. Among several other combining techniques, we suggest arctangent demodulation for quadrature channel combining and DSP is used for real-time signal processing. We also suggest DC-offset compensation technique to preserve the wanted DC components of the IQ signals for accurate demodulation while keeping the dynamic range of the ADC lower. Using Texas Instrument C6711 series DSP and external 12Bit ADC, we implemented proper elliptic digital filter and autocorrelation detection algorithm for robust commercial hand held device.

A Study on the Effectiveness of the Lungs Hand Acupuncture Based on Bio Signal Analysis (생체신호분석 기술을 적용한 폐 수지침 요법에 대한 효과성 연구)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • The KIPS Transactions:PartB
    • /
    • v.19B no.2
    • /
    • pp.77-82
    • /
    • 2012
  • We carried out study to prove effectiveness as stimulating corresponding points to lung in hand to experiment applied analysis parameters for image and audio signals in this paper. To this end we collected facial image and voice before and after stimulating corresponding points to lung in hand to a male 20s 25 people. In addition, we analyzed change color, voice energy and speaking rate of right cheek area corresponding points to lung to suggest the theory of the Oriental medicine diagnosis based on data collected. As a result, after performing hand acupuncture, L value of right cheek area decreased average 2.33 and a value b value increased 0.76, 0.97 on average. In addition, size of voice energy increased average 0.42, speaking rate decreased average 0.07. In other words, effect of lung function was improved using hand acupuncture corresponding points to lung.

The Implementation of Wireless Bio-signal Monitoring System for U - healthcare (유비쿼터스 헬스케어를 위한 무선 생체신호 감시 시스템 설계)

  • Lee, Seok-Hee;Ryu, Geun-Taek
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.82-88
    • /
    • 2012
  • In this paper, using the Android-based mobile platform designed and integrated U-healthcare systems for personal health care system is proposed. Integrated Biometric systems, electrocardiogram (ECG), oxygen saturation, blood pressure, respiration, body temperature, such as measuring vital signs throughout the module and signal processing biometric information through wireless communication module based on the Android mobile platform is transmitted to the gateway. Biometric data transmitted from a mobile health monitoring system, or transmitted to the server of U-healthcare was designed. By implementing vital signs monitoring system has been measured in vivo by monitoring data to determine current health status of caregivers had the advantage of being able to guarantee mobility respectively. This system is designed as personal health management and monitoring system for emergency patients will be helpful in the development looks U-healthcare system.

A Study on the Implementation of SoC for Sensing Bio Signal (인체신호 측정을 위한 SoC 구현에 관한 연구)

  • Sun, Hye-Seung;Song, Myoung-Gyu;Lee, Jae-Heung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.109-114
    • /
    • 2010
  • In this paper, the implementation of a human signal sensing module that has capabilities to check and restore the weak signals from the human body is presented. A module presented in this paper consists of processing and sensing elements related to human pulse and body temperature and a controller implemented with SoC design method. PPG data is detected by a noise filtering process toward the amplified signal which is from the operating frequency between 0.1Hz - 10Hz. A digital temperature sensor is used to check the body temperature. A sensor outputs the corresponding value of the electric voltage according to the body temperature. Moreover, this paper discusses the implementation of an enhanced microprocessor which is synthesized with VHDL as a part of the SoC development and used to control the entire module. The SoC processor is implemented on a Xilinx Spartan 3 XC3S1000 device and has the achieved operating frequency of 10MHz. The implemented SoC processor core is successfully tested with macro memories in FPGA and the experimental results are hereby shown.

Design of a 10-bit SAR ADC with Enhancement of Linearity On C-DAC Array (C-DAC Array내 선형성을 향상시킨 10비트 CMOS SAR ADC 설계)

  • Kim, Jeong Heum;Lee, Sang Heon;Yoon, Kwang Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.2
    • /
    • pp.47-52
    • /
    • 2017
  • In this paper, CMOS SAR A/D converter 1.8V supply for the design of an A/D converter having an middle speed for the biological signal processing was designed. This paper proposes design of a 10-bit SAR Analog to Digital Converter improving linearity driven by MSB node of C-DAC array divided into 4 equal parts. It enhances linearity property, by retaining the analog input signal charging time at MSB node. Because MSB node samples analog input, it enhances resolution through getting initial input signal precisely. By using split capacitor on C-DAC array, it reduced chip size and power dissipation. The Proposed SAR A/D Converter is fabricated in 0.18um CMOS and measured 7.5 bits of ENOB at sampling frequency 4MS/s and power supply of 1.8V. It occupies a core area of $850{\times}650um^2$ and consumes 123.105uW. Therefore it results in 170.016fJ/step of FOM(Figure of Merit).

Circuit Components Based on New Materials: The Reality of Multitechnology System on Systems Hyperintegration

  • Eshraghian, Kamran;Cho, Kyoung-Rok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.3
    • /
    • pp.106-111
    • /
    • 2010
  • The convergence of significantly different and disparate technologies such as spintronics, carbon nano tube field effect transistors, photon and bio-responsive molecular switches, memristor and memristive systems and metamaterials, coupled with energy scavenging sources are gaining a renewed focus in the quest for new products. This paper will provide an insight into an anticipated technological revolution and will highlight a futuristic Roadmap to capture opportunities that are brought about as the results of formulation of new circuit components basically driven by emergence of nanoscale materials as part of System on System integration. Challenges as the result of new lumped components such as memristor, metamaterial-based lumped components and the like that will challenge the designers' comfort zone will also be discussed.