• Title/Summary/Keyword: Bio Signal Processing

Search Result 102, Processing Time 0.03 seconds

Design of an Efficient Electrocardiogram Measurement System based on Bluetooth Network using Sensor Network (Bluetooth기반의 센서네트워크를 이용한 효율적인 심전도 측정시스템 설계)

  • Kim, Sun-Jae;Oh, Won-Wook;Lee, Chang-Soo;Min, Byoung-Muk;Oh, Hae-Seok
    • The KIPS Transactions:PartC
    • /
    • v.16C no.6
    • /
    • pp.699-706
    • /
    • 2009
  • The convergence tendency accelerates the realization of the ubiquitous healthcare (u-Healthcare) between the technology including the power generaation and IT-BT-NT of the ubiquitous computing technology. By rapidly analyzing a large amount of collected from the sensor network with processing and delivering to the medical team an u-Healthcare can provide a patient for an inappropriate regardless of the time and place. As to the existing u-Healthcare, since the sensor node all transmitted collected data by using with the Zigbee protocol the processing burden of the base node was big and there was many communication frequency of the sensor node. In this paper, the u-Healthcare system in which it can efficiently apply to mobile apparatuses it provided the transfer rate in which it is superior to the bio-signal delivery where there are the life and direct relation which by using the Bluetooth instead of the Zigbee protocol and in which it is variously used in the ubiquitous environment was designed. Moreover, by applying the EEF(Embedded Event Filtering) technique in which data in which it includes in the event defined in advance selected and it transmits with the base node, the communication frequency and were reduced. We confirmed to be the system in which it is efficient through the simulation result than the existing Electrocardiogram Measurement system.

Molecular Cloning and Expression of a Laccase from Ganoderma lucidum, and Its Antioxidative Properties

  • Joo, Seong Soo;Ryu, In Wang;Park, Ji-Kook;Yoo, Yeong Min;Lee, Dong-Hyun;Hwang, Kwang Woo;Choi, Hyoung-Tae;Lim, Chang-Jin;Lee, Do Ik;Kim, Kyunghoon
    • Molecules and Cells
    • /
    • v.25 no.1
    • /
    • pp.112-118
    • /
    • 2008
  • Laccases are multicopper-containing oxidases that catalyze the oxidation of many aromatic compounds with concomitant reduction of oxygen to water. Interest in this enzyme has arisen in many fields of industry, including detoxification, wine stabilization, paper processing, and enzymatic conversion of chemical intermediates. In this study, we cloned a laccase gene (GLlac1) from the white-rot fungus Ganoderma lucidum. The cloned gene consists of 4,357 bp, with its coding region interrupted by nine introns, and the upstream region has putative CAAT and TATA boxes as well as several metal responsive elements (MREs). We also cloned a full-length cDNA of GLlac1, which contains an uninterrupted open reading frame (ORF) of 1,560 bp coding for 520 amino acids with a putative 21-residue signal sequence. The DNA and deduced amino acid sequences of GLlac1 were similar but not identical to those of other fungal laccases. GLlac1 was released from the cells when expressed in P. pastoris, and had high laccase activity. In addition, GLlac1 conferred antioxidative protection from protein degradation, and thus may be useful in bio-medical applications.

Sensor-based Recognition of Human's Hand Motion for Control of a Robotic Hand (로봇 핸드 제어를 위한 센서 기반 손 동작 인식)

  • Hwang, Myun Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5440-5445
    • /
    • 2014
  • Many studies have examined robot control using human bio signals but complicated signal processing and expensive hardware are necessary. This study proposes a method to recognize a human's hand motion using a low-cost EMG sensor and Flex sensor. The method to classify movement of the hand and finger is determined from the change in output voltage measured through MCU. The analog reference voltage is determined to be 3.3V to increase the resolution of movement identification through experiment. The robotic hand is designed to realize the identified movement. The hand has four fingers and a wrist that are controlled using pneumatic cylinders and a DC servo motor, respectively. The results show that the proposed simple method can realize human hand motion in a remote environment using the fabricated robotic hand.

A Double Helix DNA Structure Based on the Block Circulant Matrix (I) (블록순환 행렬에 의한 이중나선 DNA 구조 (I))

  • Lee, Sung-Kook;Park, Ju-Yong;Lee, Moon-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.203-211
    • /
    • 2016
  • The genetic code is a key to bio-informatics and to a science of biological self-organizing on the whole. Modern science faces the necessity of understanding and systematically explaining mysterious features of ensembles of molecular structures of the genetic code. This paper is devoted to symmetrical analysis for genetic systems. Mathematical theories of noise-immunity coding and discrete signal processing are based on Jacket matrix methods of representation and analysis of information. Both of the RNA and Jacket Matrix property also have the Element(Block) - wise Inverse Matrices. These matrix methods, which are connected closely with relations of symmetry, are borrowed for a matrix analysis of ensembles of molecular elements of the genetic code. This method is presented for its simplicity and the clarity with which it decomposes a Jacket Matrix in terms of the genetic RNA Codon.

Extraction of Face Type and Tongue Color Analysis for Diseases Diagnosis in Web-Based Environments (웹 기반 환경에서 질병 진단을 위한 얼굴형 추출 및 설색 분석)

  • Cho, Dong-Uk;Kim, Bong-Hyun;Lee, Se-Hwan
    • The KIPS Transactions:PartB
    • /
    • v.14B no.2
    • /
    • pp.71-80
    • /
    • 2007
  • In this paper, We propose face type classification, tongue region extraction and tongue color analysis method for Oriental medicine diagnosis system to supply web based medical treatment information. This presents to construct system that takes super aging society and uses ocular inspection and longue diagnosis in web-based to embody this by an IT Technology as generalization and popularization of medical benefit are social requirement and supplies medical treatment information. Place that reflect living body signal of human body ordinarily and appear becomes iris or tongue, five sensory organs etc. This paper proposes classification of face type, extraction of five sensory organs for observing a person's shape and color among diseases diagnosis based on home health care that propose to develop and region extraction and color analysis etc, of tongue which intensively represents the bio-signals of human-beings. Finally, the effectiveness of this paper is verified by several experiments.

A Design of a Reconfigurable 4th Order ΣΔ Modulator Using Two Op-amps (2개의 증폭기를 이용한 가변 구조 형의 4차 델타 시그마 변조기)

  • Yang, Su-Hun;Choi, Jeong-Hoon;Yoon, Kwang Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.51-57
    • /
    • 2015
  • In this paper, in order to design the A / D converter with a high resolution of 14 bits or more for the biological signal processing, CMOS delta sigma modulator that is a 1.8V power supply voltage - were designed. we propose a new structure of The fourth order delta-sigma modulator that needs four op amps but we use only two op amps. By using a time -interleaving technique, we can re-construct the circuit and reuse the op amps. Also, we proposed a KT/C noise reduction circuit to reduce the thermal noise from a noisy resistor. We adjust the size of sampling capacitor between sampling time and integrating time, so we can reduce almost a half of KT/C noise. The measurement results of the chip is fabricated using a Magna 0.18um CMOS n-well1 poly 6 metal process. Power consumption is $828{\mu}W$ from a 1.8V supply voltage. The peak SNDR is measured as a 75.7dB and 81.3dB of DR at 1kHz input frequency and 256kHz sampling frequency. Measurement results show that KT/C noise reduction circuit enhance the 3dB of SNDR. FOM of the circuit is calculated to be 142dB and 41pJ / step.

Vapor Recognition Using Image Matching of Micro-Array Sensor Response from Portable Electronic Nose (휴대용 전자 후각 장치에서 다채널 마이크로 센서 신호의 영상 정합을 이용한 가스 인식)

  • Yang, Yoon-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.64-70
    • /
    • 2011
  • Portable artificial electronic nose (E-nose) system suffers from noisy fluctuation in surroundings such as temperature, vapor concentration, and gas flow, because its measuring condition is not controled precisely as in the laboratory. It is important to develop a simple and robust vapor recognition technique applicable to this uncontrolled measurement, especially for the portable measuring and diagnostic system which are expanding its area with the improvements in micro bio sensor technology. This study used a PDA-based portable E-nose to collect the uncontrolled vapor measurement signals, and applied the image matching algorithm developed in the previous study on the measured signal to verify its robustness and improved accuracy in portable vapor recognition. The results showed not only its consistent performance under noisy fluctuation in the portable measurement signal, but also an advanced recognition accuracy for 2 similar vapor species which have been hard to discriminate with the conventional maximum sensitivity feature extraction method. The proposed method can be easily applied to the data processing of the ubiquitous sensor network (USN) which are usually exposed to various operating conditions. Furthermore, it will greatly help to realize portable medical diagnostic and environment monitoring system with its robust performance and high accuracy.

Double Threshold Method for EMG-based Human-Computer Interface (근전도 기반 휴먼-컴퓨터 인터페이스를 위한 이중 문턱치 기법)

  • Lee Myungjoon;Moon Inhyuk;Mun Museong
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.471-478
    • /
    • 2004
  • Electromyogram (EMC) signal generated by voluntary contraction of muscles is often used in a rehabilitation devices such as an upper limb prosthesis because of its distinct output characteristics compared to other bio-signals. This paper proposes an EMG-based human-computer interface (HCI) for the control of the above-elbow prosthesis or the wheelchair. To control such rehabilitation devices, user generates four commands by combining voluntary contraction of two different muscles such as levator scapulae muscles and flexor-extensor carpi ulnaris muscles. The muscle contraction is detected by comparing the mean absolute value of the EMG signal with a preset threshold value. However. since the time difference in muscle firing can occur when the patient tries simultaneous co-contraction of two muscles, it is difficult to determine whether the patient's intention is co-contraction. Hence, the use of the comparison method using a single threshold value is not feasible for recognizing such co-contraction motion. Here, we propose a novel method using double threshold values composed of a primary threshold and an auxiliary threshold. Using the double threshold method, the co-contraction state is easily detected, and diverse interface commands can be used for the EMG-based HCI. The experimental results with real-time EMG processing showed that the double threshold method is feasible for the EMG-based HCI to control the myoelectric prosthetic hand and the powered wheelchair.

Carotid Artery Intima-Media Thickness Measured by Iterated Layer-cluster Discrimination (순차적 층위군집(層位群集)판별에 의한 경동맥 내중막 두께 측정)

  • Hwang Jae-Ho;Kim Wuon-Shik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.5 s.311
    • /
    • pp.89-100
    • /
    • 2006
  • The carotid intima-media thickness (IMT) is very important, because the severity of it is an independent predictor of transient cerebral ischemia, stroke, and coronary events such as myocardial infarction. The conventional image processing to measure the IMT has not been satisfactory, because the methods have relied on the manual section drawing and a regional segmentation by differential estimation. We propose a new image processing technology effective to extract features from the carotid artery image whose pixels have the directional vector properties with composed color distribution. The technique we presented here is not by differential variation but by verification of the layer properties of carotid artery image. Iterated vertical and horizontal analysis and segmentation of the IMT image show the vector characteristics. This new technique makes it possible to cluster the layers statistically, and to classify mathematical correlation between regions and resulting in correct measurements of thickness and its variation. The advantages and effectiveness of this approach are applicable to region process and character extraction of such a vector image.

Reversible DNA Information Hiding based on Circular Histogram Shifting (순환형 히스토그램 쉬프팅 기반 가역성 DNA 정보은닉 기법)

  • Lee, Suk-Hwan;Kwon, Seong-Geun;Kwon, Ki-Ryong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.67-75
    • /
    • 2016
  • DNA computing technology makes the interests on DNA storage and DNA watermarking / steganography that use the DNA information as a newly medium. DNA watermarking that embeds the external watermark into DNA information without the biological mutation needs the reversibility for the perfect recovery of host DNA, the continuous embedding and detecting processing, and the mutation analysis by the watermark. In this paper, we propose a reversible DNA watermarking based on circular histogram shifting of DNA code values with the prevention of false start codon, the preservation of DNA sequence length, and the high watermark capacity, and the blind detection. Our method has the following features. The first is to encode nucleotide bases of 4-character variable to integer code values by code order. It makes the signal processing of DNA sequence easy. The second is to embed the multiple bits of watermark into -order coded value by using circular histogram shifting. The third is to check the possibility of false start codon in the inter or intra code values. Experimental results verified the our method has higher watermark capacity 0.11~0.50 bpn than conventional methods and also the false start codon has not happened in our method.