• 제목/요약/키워드: Bio Sample

검색결과 397건 처리시간 0.187초

치과용 생체보철물 제작을 위한 TZP 단일구조 전부도재관 블럭의 물성과 저온열화 후 굴곡강도에 관한 연구 (The research about the physical properties and flexural strength changed by Low Temperature Degradation of TZP monolithic all-ceramic crown block to make bio-prosthetic dentistry)

  • 이종화;박천만;송재상;임시덕;김재도;김병식;황인환;이성국
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.83-93
    • /
    • 2012
  • Purpose: The objective of this study is to find out physical properties and the flexural strength changed by the low temperature degradation of the block which is needed to make bio-prosthetic dentistry which is better than feldspar affiliated ceramic made by building up ceramic powder and also to apply this to the clinical use of zirconia monolithic all-ceramic crown. Methods: Flexural strength of each sample was evaluated before and after the Low Temperature Degradation, and physical properties of the Tetra Zirconia Block containing 3mol % was evaluated as well. The average and standard deviation of each experimental group were came out of the evaluation. Statistical package for social science 18.0 was used for statistics. Results: The average density of the monolithic all-ceramic crown was $6.0280{\pm}0.0147g/cm$, the relative density was 99.01 %. When the sample was sintered at $1480^{\circ}C$ the diameter of average particle was $396.62{\pm}33.71nm$. All the samples had no monolithic peak after XRD evaluation but only had tetragonal peak. There were statistically significant differences in the result of flexural strength of the samples evaluated after and before the low temperature degradation, the flexural strength before the low temperature degradation was $1747.40{\ss}{\acute{A}}$, at the temperature of $130^{\circ}C$ the flexural strength after the low temperature degradation was 1063.99MPa (p<0.001). There was statistically significant difference in the result of strength of 1020.07MPa after the low temperature degradation at the temperature of $200^{\circ}C$ (p<0.001). Conclusion: The block which was made for this evaluation possesses such an excellent strength among dental restorative materials that it is thought to have no problems to use for tetragonal zirconia polycrystal.

악성 종양 환자에 대한 DR-$70^{TM}$ 면역 분석법의 의의: Validation Study (Meaning of the DR-$70^{TM}$ Immunoassay for Patients with the Malignant Tumor)

  • 이기호;조동희;김상만;이득주;김광민
    • IMMUNE NETWORK
    • /
    • 제6권1호
    • /
    • pp.43-51
    • /
    • 2006
  • Background: The DR-$70^{TM}$ immunoassay is a newly developed cancer diagnostic test which quantifies the serum fibrin degradation products (FDP), produced during fibrinolysis, by antibody reaction. The purpose of this study was to evaluate the potential of DR-$70^{TM}$ Immunoassay in screening malignant tumor. Methods: Sample subjects were 4,169 adults, both male and female, who visited the health promotion center of a general hospital from March 2004 to April 2005 and underwent the DR-$70^{TM}$ immunoassay test and other tests for cancer diagnosis. The patient group was defined as 42 adults out of the sample subjects who were newly diagnosed with cancer during the same time period when the DR-$70^{TM}$ immunoassay test was performed. Final confirmation of a malignant tumor was made by pathological analysis. Results: The mean DR-$70^{TM}$ level was $0.83{\pm}0.65{\mu}g/ml$ (range: 0.00 (0.0001)${\sim}7.42{\mu}g/ml)$ in the control group (n=4,127) as opposed to $2.70{\pm}2.33{\mu}g/ml$ (range: $0.12{\sim}9.30{\mu}g/ml)$ in the cancer group (n=42), and statistical significance was established (p<0.0001, Student t-test). When categorized by the type of malignant tumor, all cancer patients with the exception of the subgroups of colon and rectal cancer showed significantly higher mean DR-$70^{TM}$ levels compared with the control group (p<0.0001, Kruscal-Wallis test). The receiver operating characteristic (ROC) curve analysis revealed ${\geq}1.091{\mu}g/ml$ as the best cut-off value. Using this cut-off value, the DR-$70^{TM}$ immunoassay produced a sensitivity of 71.4%, a specificity of 70.1%, a positive predictability of 69.4%, and a negative predictability of 69.2% (1). Conclusion: A significant increase in the mean DR-$70^{TM}$ value was observed in the cancer group (thyroidal, gastric, breast, hepatic and ovarian) com pared with the control group. In particular, the specificity and sensitivity of the DR-$70^{TM}$ immunoassay was relatively high in the subgroups of breast, gastric, and thyroidal cancer patients. There is need for further studies on a large number of malignant tumor patients to see how the DR-$70^{TM}$ level might be changed according to the differentiation grade and postoperative prognosis of the malignant tumor.

공기감염성 가축질병 예방을 위한 공기청정기 유형에 따른 부유 미생물의 제거 효과 (Reduction Effect of Various Air Purifiers on Airborne Microorganism for Preventing Air Infected Animal Disease)

  • 박찬정;김현태;김기연
    • 농업생명과학연구
    • /
    • 제45권3호
    • /
    • pp.89-96
    • /
    • 2011
  • 본 연구의 목적은 공기감염성 가축질병 유발의 주요 인자인 부유 세균 및 바이러스 등의 생물학상 인자들에 대한 유형별 공기청정기의 제균 효과를 비교 평가하는 데 있다. 시료 채취 장비에 대한 포집 성능 평가에서는 MS2 바이러스와 Pseudomonas fluorescens 모두 Button sampler보다는 Biosampler에 의한 채취 효율이 유의하게 높았다 (p<0.05). 공기청정기 유형 및 시료채취 방법에 관계없이 MS2 바이러스의 경우 초기 농도 대비 가동 후 5분에 50% 이상, 15분에 70% 이상, 30분에 80% 이상, 그리고 마지막 측정 시점인 60분에는 90% 이상의 제거 효율을 보이는 것으로 나타났다. P. fluorescens 세균의 경우 초기 농도 대비 가동 후 5분에 45% 이상, 15분에 50% 이상, 30분에 70% 이상, 그리고 마지막 측정 시점인 60분에는 75% 이상의 제거 효율을 보이는 것으로 나타났다. 유형별 공기청정기의 상대적 제균 효율을 비교해 보면 MS2 바이러스의 경우 이온 발생 방식>전기 집진 방식>습식 방식>건조 방식, P. fluorescens 세균의 경우 전기 집진 방식>이온 발생 방식>건조 방식>습식 방식의 순서로 조사되었다.

다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교 (Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins)

  • 김명정;이승구
    • 광물과 암석
    • /
    • 제35권4호
    • /
    • pp.507-520
    • /
    • 2022
  • 지질과학 분야에서 암석의 생성 시기, 지각과 맨틀 진화연구의 기초자료로 활용되는 Sr 동위원소비는 열이온화 질량분석기(thermal ionization mass spectrometry, TIMS) 혹은 다검출기 유도결합 플라즈마 질량분석기(multi-collector plasma ionization mass spectrometry, MC-ICP-MS)와 같은 질량분석기를 이용하여 측정할 수 있다. 이 기술보고에서는, Sr 동위원소비 측정시, 원소의 불완전한 화학적 분리가 Sr 동위원소비의 참값 (true value)에 어떤 영향을 미치는지를 비교하였다. 실험에는 상업용 레진, NBS987(NIST SRM987) Sr 동위 원소 표준물질 그리고 일본지질조사소의 암석표준시료 JG1a, JB3, JA1를 이용하였다. 비교실험 결과, NBS987 Sr 동위원소 표준시료, 일본지질조사소의 암석표준시료 JG1a, JB3, JA1 모두 불완전한 분리에 의해 Rb이 남아있는 경우 87Sr/86Sr의 측정값이 변하는 것이 명확하게 관찰된다. 이는 질량분석기 특히 MC-ICP-MS로 동위 원소비를 측정하고자 하는 경우, 동종동위원소의 간섭에 대한 보정에도 불구하고 측정값은 참값에서 벗어나므로 완전한 분리가 중요한 인자임을 지시해준다. 그러므로 MC-ICP-MS를 이용한 Sr 동위원소비 측정결과를 보고할 때는, 동종동위원소에 의한 영향을 판단할 수 있도록 Sr의 동위원소 전체의 측정강도와 더불어 85Rb의 측정강도도 함께 보고돼야 할 것이다.

집속형초음파자극시스템 카트리지의 동물실험을 통한 피부자극시험 및 피부 감작성시험 (Animal Skin Irritation and Skin Sensitization Tests of High Intensity Focused Ultrasound System Cartridges)

  • 김준태;김주희;주규태;김경아;최안렬;조재현;정진형
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.477-484
    • /
    • 2022
  • 본 연구는 집속형초음파자극시스템의 카트리지부를 시료로 사용하여 의료기기 안전성 평가 기준인 GLP(Good Laboratory Practice)에 관한 시험 중 동물실험을 통한 피부 자극 시험 및 피부 감작성시험을 진행하였다. New Zealand White Rabbit 암컷 6마리를 이용하여 IACUC 승인 후 시험을 진행하였으며, 실험기간 동안 사망한 개체 수는 없었으며, 실험동물에서 어떤 이상 증상도 관찰되지 않았다. 극성, 비극성 자극 지수는 모두 '0.0'으로 나타났다. 또한, 피부감작성 평가의 경우 IACUC 승인을 통한 기니피그 30마리를 통하여 대조군 및 실험군으로 나누어 시험검체 및 공시험액을 별도의 희석 없이 용출액 자체를 사용하여 모든 유도 및 유발단계를 적용하였다. 실험결과대조동물의 피부반응 등급은 0등급이었으며, 시험동물의 피부반응에서 1등급 이상을 나타내는 동물은 없었다. 두 시험 결과에서 피부의 이상 증상은 발견되지 않았으며, 인체에 적용하여 환자를 치료할 경우 시험에 사용된 시험재료로부터 피부의 이상 증상이 생기는 질환 등은 나타나지 않는지에 관하여 안정성을 알아 보고자 하였다.

Research on Real-Time Portable Quality Evaluation System for Raw Milk

  • Lee, Dae Hyun;Kim, Yong Joo;Min, Kyu Ho;Choi, Chang Hyun
    • Agribusiness and Information Management
    • /
    • 제6권2호
    • /
    • pp.32-39
    • /
    • 2014
  • The goal of this research was to develop a portable system that could be used to evaluate the quality of milk in real time at a raw milk production site. A real-time portable quality evaluation system for raw milk was developed to enable non-destructive quality evaluation of somatic cell count (SCC), fat, protein, lactose, and total solid (TS) in milk samples. A prediction model of SCC, fat, protein, lactose, and TS was constructed using partial least squares (PLS) and 200 milk samples were used to evaluate the prediction performance of the portable quality evaluation system and high performance spectroscopy. Through prediction model development and verification, it was found that the accuracy of high performance spectroscopy was 90% for SSC, 96% for fat, 96% for protein, 91% for lactose, and 97% for TS. In comparison, the accuracy of the portable quality evaluation system was relatively low, at 90% for SSC, 95% for fat, 92% for protein, 89% for lactose, 92% for TS. However, the measurement time for high performance spectroscopy was 10 minutes for 1 sample, while for the portable quality evaluation system it was 6 minutes. This means that the high performance spectroscopy system can measure 48 samples per day (8 hours), while the portable quality evaluation system can measure 80 (8 hours). Therefore, it was found that the portable quality evaluation system enables quick on-site quality evaluation of milk samples.

식물정유 10 종의 라디칼 소거 활성과 주요 활성 성분의 탐색 (Radical Scavenging Effects of 10 Plant Essential Oils and Active Compound Screening Analysis)

  • 김아영;표병식;김선민;박미진;이성숙;이경인
    • 한국약용작물학회지
    • /
    • 제27권6호
    • /
    • pp.427-435
    • /
    • 2019
  • Background: A growing interest in health has increased the need for the development of potent antioxidant materials known to play a role in various physiological activities. Currently research and development of non-toxic natural antioxidants with high activity is ongoing. Methods and Results: In this study, we measured 2,2'-azinobis- (3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging ability of 10 plant essential oils, selecting samples of Dendranthema indicum, Dendranthema zawadskii, and Citrus sunki essential oils. The samples were analyzed using liquid chromatography (LC) and the radical scavenging activity on LC-based systems with the same conditions. In the LC-mass spectroscopy (MS)/MS analysis of the active compound peak, 2-methoxy-4-vinylphenol with a molecular weight of 150.1 g/mol was identified in C. sunki essential oils. Eugenol or isoeugenol with a molecular weight of 164.1 g/mol as identified in D. indicum and D. zawadskii essential oils as radical scavenging active compounds. Conclusions: In the LC-based measurement system, the active ingredient can be identified by simultaneously conducting profile analysis and the radical scavenging activity of essential oil samples. In addition, LC-MS/MS analysis of the active compound peaks can be performed under the same separation conditions to obtain data that can identify the active compounds in the sample.

Recapitulation of Genome-wide Association Study on Chronic Periodontitis in a Korean Population

  • Park, Bo-Ruem;Ma, Jae-Kyung;Park, Kwang-Bum;Hong, Kyung-Won
    • 대한의생명과학회지
    • /
    • 제23권2호
    • /
    • pp.133-137
    • /
    • 2017
  • Periodontitis is the major causation of tooth loss in the elderly population. Multiple risk factors include oral microorganisms, smoking, metabolic syndrome, and genetic factors influence periodontitis development. In this study, we conducted a replication study of using previous Korean GWAS results by examining an independent population. The study population was recruited from Mir Dental Clinic, Daegu, Korea. In total, 93 samples were evaluated from July 2016 to January 2017. The sample groups include relatively older patients (>60 years) with no periodontitis (n = 31) and relatively younger patients (range 40~60 years) with severe periodontitis (n = 62). A total of seven markers which were previously reported to be associated with periodontitis were genotyped. Among the seven SNPs, rs16846206 and rs2392510 showed a significant association by logistic regression analysis and Chi square test, respectively. The former SNP showed significant association with severe periodontitis, whereas this study also showed same tendency in which individuals with the minor allele are significantly more frequent in cases than those in controls. The SNP is located on a coding gene (SLC9C2), where the alanine residue 505 is replaced by glycine (Ala505Gly). The later SNP was significant when differed between case and control groups, but there was no significance by logistic regression analysis when controlled for age and sex as covariant. Although the study population size examined in the current study was relatively smaller compared to previous studies, our results implicated that at least the two SNPs (rs16846206 and rs2392510) might be important candidates for the further genetic study.

Numerical Modeling and Experiment for Single Grid-Based Phase-Contrast X-Ray Imaging

  • Lim, Hyunwoo;Lee, Hunwoo;Cho, Hyosung;Seo, Changwoo;Lee, Sooyeul;Chae, Byunggyu
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.83-91
    • /
    • 2017
  • In this work, we investigated the recently proposed phase-contrast x-ray imaging (PCXI) technique, the so-called single grid-based PCXI, which has great simplicity and minimal requirements on the setup alignment. It allows for imaging of smaller features and variations in the examined sample than conventional attenuation-based x-ray imaging with lower x-ray dose. We performed a systematic simulation using a simulation platform developed by us to investigate the image characteristics. We also performed a preliminary PCXI experiment using an established a table-top setup to demonstrate the performance of the simulation platform. The system consists of an x-ray tube ($50kV_p$, 5 mAs), a focused-linear grid (200-lines/inch), and a flat-panel detector ($48-{\mu}m$ pixel size). According to our results, the simulated contrast of phase images was much enhanced, compared to that of the absorption images. The scattering length scale estimated for a given simulation condition was about 117 nm. It was very similar, at least qualitatively, to the experimental contrast, which demonstrates the performance of the simulation platform. We also found that the level of the phase gradient of oriented structures strongly depended on the orientation of the structure relative to that of linear grids.

수질자동모니터링시스템의 설치 현황과 전망 (A Real Time Monitoring for Water Quality of River)

  • 류재근
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.1-11
    • /
    • 2004
  • Water quality is monitored at 1,837 points which are streams and sources for water supply in Karea. The monitoring carry out the measurement of 16 parameters of pH, BOD, SS, DO and so on with once a month, and of other parameters such like heavy metal with once a quarter. But most of the monitoring is carried out uncontinuously, so it is very difficult to understand exactly the changes of water quality compared with continuous monitoring. Therefore, real time monitoring system was equipped with basic parameters such as pH, temperature, DO, turbidity and electric conductivity at 25 major sources of water supply after installation of Noryangjin and Dukdo in 1974. But the systems have some problems which cannot be considered the sampling sites to represent for water quality of stream of lake, and can be caused a change of water quality by long distance from analyzer to intake pipe. Therefore, it has carefully to evaluate selection of sample sites for real time monitoring system. Also, problems on the area has been to identify which parameters are best suited to monitoring stream of lake water and the differences, of analyzing results compared with manual analyzing. This paper presents some approaches to handle such problems, namely selection of sampling site and measurable parameters, to connect with bio-monitoring system solving a Limitation of measurable parameters, The bio-monitoring system of an early alarm that is desirable to perceive a toxic material inflow into stream can be applied to continuos water quality monitoring system effectively. Also, this paper presents to build a on line system transmitting immediately from a mobile analyzer house or container to main monitoring center the results of analyzer by a telemeter.