• Title/Summary/Keyword: Binocular function

Search Result 70, Processing Time 0.021 seconds

The Accommodative Lag and Refractive Error in Early Adults (초년 성인의 굴절이상과 조절래그 분포의 연관성)

  • Baarg, Saang-Bai;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.59-65
    • /
    • 2012
  • Purpose: The purpose of this study was to determine the distribution and correlation of accommodative lag with refractive error. Method: We had tested the clinical refraction and the accommodative lag in clinically normal 49 young adults (total 98 eyes) aged 18 to 25 years without abnormal binocular function. Monocular and binocular accommodative lag were tested with 0.50 D cross-cylinder lens and near vision test chart which had cross-hairs after full correction of LogMAR visual acuity over 0.05. Results: There was no statistical differences in monocular accommodative lag between right ($0.64{\pm}0.64$ D) and left eye ($0.63{\pm}0.64$)(p=0.858). The accommodative lag of male was higher than female and the range of the value was broader than female in binocular accommodative lag (p=0.015). The wider the inter-pupillary distance was, the higher the accommodative lag was (p=0.003). However, there were no differences with age (p=0.800) and dominant eye (p=0.402). The ranges of accommodative lag of low, middle, and high myopia were 0.75 ~ -0.25 D, 1.25 ~ -0.50 D, and 1.50 ~ -0.75 D, respectively, and the regression was 'y = -0.03953x+0.09205'. Conclusions: These data suggest that clinically normal young adults with high amounts of refractive error have more variable accommodative lag and increased spherical equivalent refraction.

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

The Purchasing Trends of Purchase of Functional Progressive Addtions Lenses and Correlation Analysis of Binocular Function Value (기능성누진렌즈 구매고객의 구매동향 및 양안시기능값 상관성 분석)

  • Kim, Dong-min;Lee, Gi-yung;Park, Hyun-ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.255-261
    • /
    • 2015
  • Purpose: purchasing status and understanding trends of Functional progressive addtions lenses buyers', Correlation analysis of the Binocular Function value to determine ADD then can be apply sales and prescriptions. Methods: Years 2011 to 2014, 298 patients who were prescribed functional progressive lenses were analysed based on the prescription data and SPSS (Ver. 20.0) was treated using the statistics. Results: Results: The average age of our customers are $27.66{\pm}11.55$ years, average addition power is $+0.73{\pm}0.36D$, customers are using take a prescription of ADD $+0.75{\pm}0.28D$ was the highest 44.33% to 132 people. Near point of convergence of 276 people (92.62%) was mostly less than 10 cm, and near point of accommodation of 134 people (44.97%) was also below 10 cm, within 11~15 cm were 122 people (40.94%). Most of people were within normal range in terms of Near point of convergence and near point of accommodation, near point of accommodation tend to be longer than Near point of convergence. As you can see this result shows most of customers need extra help in their near point of accommodation instead of they are leak at it. FCC (Fused cross cylinder) check Value and ADD (addition power) tests showed that the value of a strong correlation (p=0.00), NPC and NPA were also p=0.001, the correlation of the NPC and ADD is p=0.003, In addition, NPA and ADD also showed a significant correlations (p=0.005). Near Point of Accommodation, negative relative accommodation, and positive relative accommodation are all significantly correlated (p=0.00). The short distance-related variables of the ADD which are NPC, NPA, Age, also appeared to side correlate significantly with each other. Conclusion: Binocular function values of the subjects were highly correlated with each other so precise examination is required. when Age young people are working at short distance, low ADD values was prescribed for solving discomfort. So, in the case of early presbyopia, accommodative insufficiency, or people feel fatigue when they often working at near although their accommodation function is normal, when functional progressive lenses are prescribed, expectation of this should be exactly notified.

The variation of visual acuity for a artificial myopia concerned with the fogging technique (운무법과 같은 인위적인 근시상태에서의 시력 변화)

  • Choi, Woon Sang;Park, Soo Bong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.43-47
    • /
    • 1996
  • For youths of both sexes which can read the letter chap of 1.0 acuity without lens, tests the fogging technique and examines the development of visual acuity. And compare the numerical function with the result of the variation of the blur circle on the retina when the power of the fogging lens varies. The variation of visual ac acuity for the fogging technique keeps constantly the balance for binocular.

  • PDF

Universal Stereoscopic Display Using 64 LCD's

  • Takaki, Yasuhiro
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.289-292
    • /
    • 2002
  • A new technique to construct an auto-stereoscopic display that offers massive horizontal parallax images is proposed Multiple telecetnric imaging systems are arranged in a modified 2D array. The horizontal parallax images displayed by LCD panels are imaged to be superimposed on a 3D screen. All parallax images are displayed in the different horizontal directions because all imaging systems have different horizontal positions. The difference of the vertical display directions due to the imaging system's vertical positions is canceled by a vertical diffuser placed at the 3D screen. Observers can percept 3D images with the binocular disparity, the vergence, and the smooth motion parallax. In addition, the accommodation function may also work because a number of parallax images are displayed with a very small angle interval in the horizontal direction. A prototype 3D display including 64 color LCD panels was constructed.

  • PDF

A Study on the Phoria of Korean Male and Female Adults (한국인 성인 남녀의 사위에 관한 연구)

  • Sung, Duk Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.59-63
    • /
    • 2001
  • Once refractive error of the eye was fully corrected. Polarization Test was used to investigate binocular vision function. As the results of phoria measurement of Korean adults for 53males and 59 females, orthophoria in 27.68%, esophoria in 12.50%, exophoria in 48.21%, verical phoria in 3.75%, esophoria(+verical phoria) in 2.68%, and exophoria(+vertical phoria) in 5.36%, respectively. Horizontal phoria is below $3{\Delta}$ mostly and verical phoria is below $1{\Delta}$.

  • PDF

Development of a Compact 3-D HDTV Camera with Zoom Lens

  • Yamanoue, H.;Okui, M.;Okano, F.;Yuyama, I.
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.49-54
    • /
    • 2001
  • Research on shooting conditions of 3D program production for natural 3D images has been continued. In the study, it has been shown that orthostereoscopic conditions bring about no inconsistency between depth information from perspective of the lenses and that from binocular parallax. A newly developed 3D camera is based on orthostereoscopic conditions, which result in compactness of the camera (weight 8). At the same time, the new camera has a zooming function and is valuable in many ways, especially sport broadcasting. In this paper, we give an outline of the newly developed 3D HDTV camera and the results of subjective evaluation tests on psychological effects of the images shot by the camera. These tests show that the images shot by this camera are more powerful and comfortable to view than those shot by existing 3D cameras.

Automatic crack detection of dam concrete structures based on deep learning

  • Zongjie Lv;Jinzhang Tian;Yantao Zhu;Yangtao Li
    • Computers and Concrete
    • /
    • v.32 no.6
    • /
    • pp.615-623
    • /
    • 2023
  • Crack detection is an essential method to ensure the safety of dam concrete structures. Low-quality crack images of dam concrete structures limit the application of neural network methods in crack detection. This research proposes a modified attentional mechanism model to reduce the disturbance caused by uneven light, shadow, and water spots in crack images. Also, the focal loss function solves the small ratio of crack information. The dataset collects from the network, laboratory and actual inspection dataset of dam concrete structures. This research proposes a novel method for crack detection of dam concrete structures based on the U-Net neural network, namely AF-UNet. A mutual comparison of OTSU, Canny, region growing, DeepLab V3+, SegFormer, U-Net, and AF-UNet (proposed) verified the detection accuracy. A binocular camera detects cracks in the experimental scene. The smallest measurement width of the system is 0.27 mm. The potential goal is to achieve real-time detection and localization of cracks in dam concrete structures.

Evaluation of Applicability of Webtoon Content for Visual Function Education and Consultation for the General Public (일반인을 위한 시각기능 교육 및 상담용 웹툰 콘텐츠의 적용 가능성 평가)

  • Chang Won Park;Hyojin Won
    • Journal of Industrial Convergence
    • /
    • v.22 no.6
    • /
    • pp.99-106
    • /
    • 2024
  • The author thought about how to explain visual functions in an easy-to-understand way to customers visiting the optical shops and provide easy customer consultation, and attempted to evaluate the usability and value of the educational webtoon for patient consultation by applying it to the optical shops's visitors. Survey study was conducted targeting 152 customers who visited optical shops A in Incheon from January to December 2023. In this study, consultation was conducted using educational webtoons to help the general public understand concepts that are difficult to understand, such as binocular vision function, the concept of heterophoria, prism lenses, and binocular balance. The areas of 'understanding', 'interest', 'usability', 'necessity', and 'expression of expertise' felt by the visitors who received counseling were scored and evaluated, and differences according to counseling method were evaluated using an independent sample t-test. Statistical verification was performed. When the optometrist only explained verbally, the score distribution was relatively low: 1.96 points for understanding, 2.06 points for interest, 2.96 points for usability, 4.20 points for necessity, and 3.19 points for expertise. When the optometrist provided explanations along with the book, understanding was 4.14 points, interest was 3.28 points, usability was 3.60 points, necessity was 4.17 points, and expertise was 3.55 points. When the optometrist explained with a webtoon, understanding was 4.57 points, interest was 4.96 points, usability was 4.18 points, necessity was 4.65 points, and expertise was 3.15 points. When explanations were given only verbally, all items showed the lowest scores, whereas consultations using webtoons showed 4 points or more (excellent) in all items except the 'expression of expertise' item. It is evaluated that actively using webtoons in various consultation situations that occur in optical shops will help increase customer interest and concentration.

Relationship Between the Degree of Exophoria and Stereoacuity (외사위의 정도와 입체시의 관계)

  • Shin, Hoy-Sun;Lee, Sun-Haeng;Yun, Mi-Ok;Kim, Mi-Yeon;Bea, Hong-Sup;Park, Sang-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.41-46
    • /
    • 2009
  • Purpose: Stereopsis is one of primary characteristics for assessment of binocular function. The purpose of this study was to determine the possible relationship between the degree of exophoria and stereoacuity at near. Methods: 110 exophores (male n=71, female n=39, mean $age{\pm}SD=11.30{\pm}1.47$ years) without amblyopia, strabismus, and ocular and systemic pathology were studied. Subjects were also excluded if they had visual acuity poorer than 0.8 in either eye or vertical phoria greater than 1 prism diopter. Clinical tests were performed for near phorias by von Graefe technique using a Digital Refractor (CDR-3100, Huvitz, Korea) with chart (Predio CDC-4000, Huvitz, Korea), and for stereoacuity using the Titmus fly. Results: A one-way analysis of variance revealed that mean values of the stereoacuity classified according to the degrees of the exophoria were not significantly different (p>0.05). Conclusions: Based on the result of this study, it was found that there was no relationship between the degree of exophoria and stereoacuity.

  • PDF