• 제목/요약/키워드: Bin(X)

검색결과 413건 처리시간 0.03초

X-선 영상 시스템의 정밀 캘리브레이션 기법 (An Accurate Calibration Technique for X ray Imaging System)

  • 조영빈;권대갑
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.198-207
    • /
    • 1999
  • This paper presents an accurate algorithm for geometric calibration of X-ray imaging system. Calibration is a very important process for improving an imaging system performance. There has been a lot of previous works using linear camera modeling technique, where lens distortion is neglected and/or center of distortion is assumed to be known. Geometrical distortion of image intensifier, however, is very large and its center of distortion should be calculated. This paper presents a new calibration method to estimate the intensifier position and orientation, scale factor, distortion coefficient, magnification factor, and center of distortion using the least square method. We investigate the properties of the algorithm by computer simulation. Simulation results show that the parameters can be estimated accurately using the proposed algorithm.

  • PDF

Effects of Ni Addition on the Microstructures and Magnetic Properties of Fe70-xPd30Nix High-Temperature Ferromagnetic Shape Memory Alloys

  • Lin, Chien-Feng;Yang, Jin-Bin
    • Journal of Magnetics
    • /
    • 제17권2호
    • /
    • pp.86-95
    • /
    • 2012
  • This study investigated the effects of adding a third alloying element, Ni, to create $Fe_{70-x}Pd_{30}Ni_x$ (x = 2, 4, 6, 8 at.% Ni) ferromagnetic shape memory alloys (FSMAs). The Ni replaced a portion of the Fe. The $Fe_{70-x}Pd_{30}Ni_x$ alloys were homogenized through hot and cold forging to gain a ~38% reduction in thickness, next they were solution-treated (ST) with annealing recrystallization at $1100^{\circ}C$ for 8 h and quenched in ice brine, and then aged at $500^{\circ}C$ for 100 h. Investigation of the microstructures and magnetostriction indicated that the greater Ni amount in the $Fe_{70-x}Pd_{30}Ni_x$ alloys reduced saturation magnetostriction at room temperature (RT). It was also observed that it was more difficult to generate annealed recrystallization. However, with greater Ni addition into the $Fe_{70-x}Pd_{30}Ni_x$ (x = 6, 8 at.% Ni) alloys, the $L1_0+L1_m$ twin phase decomposition into stoichiometric $L1_0+L1_m+{\alpha}_{bct}$ structures was suppressed after the $500^{\circ}C$/100 h aging treatment. The result was that the $Fe_{70-x}Pd_{30}Ni_x$ (x = 6, 8 at.% Ni) alloys maintained a high magnetostriction and magnetostrictive susceptibility (${\Delta}{\lambda}{_\parallel}{^s}/{\Delta}H$) after the alloys were aged at $500^{\circ}C$ for 100 h. This magnetic property of the $Fe_{70-x}Pd_{30}Ni_x$ (x = 6, 8 at.% Ni) alloys make it suitable for application in a high temperature (T > $500^{\circ}C$) and high frequency environments.

TeOx(x=1.42)/SiO2로 구성된 광가변적인 1차원 광자결정 연구 (A Study on the Photo Reversible One-dimensional Photonic Crystals Composed of TeOx(x=1.42)/SiO2)

  • 공헌;여종빈;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제28권2호
    • /
    • pp.99-103
    • /
    • 2015
  • One-dimensional photonic crystals (1D PCs) were fabricated by RF sputtering technique on p-Si (100), and fused quartz substrates. The 1D PCs structures consisted of $TeO_x$ (x=1.42), and $SiO_2$ with the difference refractive index. In order to estimate the effect on a defect level within 1D PCs structures, samples were prepared with both normal, and defect mode. The structural and optical properties were confirmed by Scanning electron microscope (SEM), and Ultraviolet visible near-infrared spectrophotometer (UV-VIS-NIR) respectively. In the case of a 1D PC normal mode without defect layer, it had a photonic band gap (PBG) in the near infrared (NIR) region. In the case of a 1D PC defect mode with defect layer, it had a sharp transmission band owing to a defect level, and moved towards the longer wavelength after exposing He-Cd laser with a wavelength of 325 nm.

Evaluations of Sb20Se80-xGex (x = 10, 15, 20, and 25) Glass Stability from Thermal, Structural and Optical Properties for IR Lens Application

  • Jung, Gun-Hong;Kong, Heon;Yeo, Jong-Bin;Lee, Hyun-Yong
    • 한국세라믹학회지
    • /
    • 제54권6호
    • /
    • pp.484-491
    • /
    • 2017
  • Chalcogenide glasses have been investigated in their thermodynamic, structural, and optical properties for application in various opto-electronic devices. In this study, the $Sb_{20}Se_{80-x}Ge_x$ with x = 10, 15, 20, and 25 were selected to investigate the glass stability according to germanium ratios. The thermal, structural, and optical properties of these glasses were measured by differential scanning calorimetry (DSC), X-ray diffraction (XRD), and UV-Vis-IR Spectrophotometry, respectively. The DSC results revealed that $Ge_{20}Sb_{20}Se_{60}$ composition showing the best glass stability theoretically results due to a lower glass transition activation energy of 230 kJ/mol and higher crystallization activation energy of 260 kJ/mol. The structural and optical analyses of annealed thin films were carried out. The XRD analysis reveals obvious results associated with glass stabilities. The values of slope U, derived from optical analysis, offered information on the atomic and electronic configuration in Urbach tails, associated with the glass stability.

Behavior-induced Disposable Cup Automatic Separation X-Bin Study

  • LEE, Su-Min;KIM, Seo-Hyun;KIM, Ye-Na;BYUN, Hyo-Jeong;KWON, Lee-Seung;JUNG, Min-Jae;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제4권1호
    • /
    • pp.19-25
    • /
    • 2021
  • Purpose: This study seeks to develop behavior-induced automatic separation X-Bin for disposable cup speculators. Some students throw away the contents. Research design, data and methodology: Therefore, environmental beautification workers spend a lot of time sorting disposable cups at school garbage collection sites. Disposable cups that have been thrown away like this are bad in terms of appearance and smell. In addition, cleaning inside garbage affects recycling rates and is closely related to environmental problems. Results: Clean cleaning reduces the amount of garbage incinerated without being recycled and reduces the cost of recycling. According to Korean Social Trends 2020, COVID-19 began to spread, and recycling of disposable items such as disposable cups increased by about 15 percent from the same period last year. Conclusions: These are classified for recycling, and the amount of garbage thrown on the streets is estimated to be larger. In order to prevent COVID-19s, the use of disposable goods is inevitable, but facilities are needed to dispose of them properly.

PRAM을 위한 $(GeTe)_x(Sb_2Te_3)$ 박막의 XPS, EXAFS, XRD 분석 (XPS, EXAFS, XRD Analysis of $(GeTe)_x(Sb_2Te_3)$ Thin Films for PRAM)

  • 임우식;김준형;여종빈;이은선;조성준;이현용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.132-133
    • /
    • 2006
  • PRAM (phase-change random access memory)은 전류 펄스 인가에 따른 기록매질의 비정질-결정질 간 상변화와 그에 동반되는 저항변화를 이용하는 차세대 비휘발성 메모리 소자로서 연구되어지고 있다. 본 논문에서는 $(GeTe)_x(Sb_2Te_3)$ pseudobinary line을 따르는 조성(x=0.5, 1, 2, 8)의 벌크 및 박막시료를 제작하고 원자-스케일의 구조적 상변화를 분석하였다. 열증착을 이용하여 Si 기판위에 200nm 두께의 박막을 형성, 질소분위기 하에서 100-450도 범위에서 열처리 하였다. XRD를 통해 열처리 온도에 따른 구조적 분석을 실시하였다. x=8의 조성을 제외한 전체 박막에 대해 열처리 온도 증가에 따라 fcc와 hexagonal 구조가 순차적으로 나타났으며 일부에서는 혼종의 상구조를 보였다. 특히, $Ge_2Sb_2Te_5$ 박막에 대하여 EXAFS (extended x-ray absorption fine structure) 및 XPS를 이용하여 상변화의 원자-스케일 구조분석을 하였다.

  • PDF

Determination of buildup factors for some human tissues using both MCNP5 and Phy-X / PSD

  • Mohammad M. Alda'ajeh;J.M. Sharaf;H.H. Saleh;Mefleh S. Hamideen
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4426-4430
    • /
    • 2023
  • In this article, Exposure Buildup Factor(EBF) and the Energy Absorption Buildup Factor(EABF) have been determined for blood, brain, and muscle using the Monte Carlo method which is represented by MCNP5 codes and compared with geometric progression(G-P) fitting method which is represented by Phy-X/PSD online platform. The novelty of the present work is used an energy source of less than 0.1 MeV to determine buildup factors using MCNP5 and using Phy-X/PSD for some human tissues. thus, the energy range used in this case study was 0.06-3 MeV for penetration depths covered 0.5-3 MFP. Results of MCNP5 and Phy-X/PSD are validated against reference values of water that were reported at ANS-6.4.3. present results of EABFs and EBFs for the previously mentioned human tissues appeared good agreement between MCNP5 in comparison with Phy-X/PSD, whereas, the maximum average relative deviation did not exceed 2.37%. results of our article can be used in different medical applications, such as brachytherapy, radiotherapy, and diagnostics.

분무건조와 용매증발을 이용한 Kollidon VA 64에 포접된 아세클로페낙의 개선된 용출 거동 (Improved Dissolution Behavior of Aceclofenac Loadings with Kollidon VA 64 Using Spray Drying and Rotary Evaporation Process)

  • 양재원;박진영;이천중;김혜민;이현구;장나금;고현아;조선아;양대혁;강길선
    • 폴리머
    • /
    • 제39권1호
    • /
    • pp.6-12
    • /
    • 2015
  • 난용성 약물인 아세클로페낙의 용해도를 개선하기 위해 약물과 고분자의 다른 비율을 사용하여 분무건조와 용매증발의 방법으로 Kollidon VA 64의 고체분산체를 제조하였다. 아세클로페낙을 포접하는 고체분산체의 형태학적, 물리화학적 분석을 하기 위해, 전자주사현미경(SEM), 푸리에변환 적외선분광법(FTIR), 시차주사 열량측정법(DSC) 등이 사용되었다. 포접률과 인공장액에서의 용출 거동은 HPLC를 사용하여 측정하였고, 비교를 위해 원약물과 시판제 Airtal$^{(R)}$이 사용되었다. 이것은 두 가지 방법에 따라 개선된 용출 거동을 나타내었다.

PVP 첨가에 의해 제조된 올메사탄 메독소밀 고체분산체의 방출패턴 연구 (Release Behavior of Olmesartan Medoxomil from Solid Dispersion Prepared by PVP Addition)

  • 오승창;이천중;이현구;박진영;정현기;김영래;임동권;이동원;강길선
    • 폴리머
    • /
    • 제39권1호
    • /
    • pp.33-39
    • /
    • 2015
  • 올메사탄은 BCS 2단계에 해당하는 약물로 물에 잘 녹지 않는 난용성 약물이다. 이런 약물이 낮은 생체이용률과 제형을 설계하는 과정에서 어려움을 주는 원인이 된다. 본 연구에서는 올메사탄을 분무건조법 및 회전용매증 발법을 이용해 고체분산체를 제조하여 제법에 따른 난용성약물의 용출률을 확인하였다. 수용성 고분자로 PVP를 사용하여 약물과 고분자의 비율별로 고체분산체를 제조하였다. SEM을 이용하여 고체분산체의 형태학적인 특성을 분석하였고, 고체분산체의 결정학적 성질은 XRD와 DSC를 통하여 확인하였다. 또한 FTIR을 통해 화학적인 변화를 확인하고, 생체 외 용출거동 실험을 통하여 변화된 용출률을 확인하였다. 제조된 고체분산체는 pH 1.2에서 용출을 확인하였으며, 올메텍과 용출률을 비교하였으며, 분무건조를 통해 약물의 용출률을 향상시킬 수 있다는 것을 확인할 수 있다.