• 제목/요약/키워드: Bending performance test

검색결과 425건 처리시간 0.033초

부재단면 형상에 따른 부재 굽힘붕괴 특성의 폼 충진 효과 (Foam Filling Effect on Bending Collapse Characteristics for Member Section Type)

  • 이일석;강성종
    • 한국자동차공학회논문집
    • /
    • 제15권2호
    • /
    • pp.41-49
    • /
    • 2007
  • More diversified and strengthened safety regulations require higher safety vehicle with less weight. The structural foam can play a role for restraining section distortion of main body members undergoing bending collapse at vehicle crash. In this study, using structural foam modeling technology, validated in previous work, the bending collapse characteristics were evaluated for two types of circular and actual vehicle body frame sections. With changing the foam filling method, outer panel thickness and section shape, load carrying capability and absorbed energy were observed. The results indicate valuable design strategy for effectively elevating bending collapse performance of body members with foam filled.

유연 기판과 전극 사이의 접합력이 전극의 내구성에 미치는 영향 (Effect of Adhesion Strength Between Flexible Substrates and Electrodes on the Durability of Electrodes)

  • 임도연;김병준;김건휘;안태창
    • 센서학회지
    • /
    • 제33권2호
    • /
    • pp.86-92
    • /
    • 2024
  • Flexible electronic devices are exposed to repeated mechanical deformation; therefore, electrode performance is an important element. Recently, a new technology has been developed to improve the adhesion strength between polymer substrates and metal thin films through the cross-linking reaction of bovine serum albumin (BSA) bioconjugation proteins; however, additional performance evaluation as an electrode is necessary. Therefore, in this study, we investigated the effect of adhesive strength between a flexible substrate and a metal thin film on the performance of a flexible electrode. Cracks and changes in the electrical resistance of the electrode surface were observed through outer bending fatigue tests and tensile tests. As a result of a bending fatigue test of 50,000 cycles and a tensile test at 10% strain, the change in the electrical resistance of the flexible electrode with a high adhesion strength was less than 40%, and only a few microcracks were formed on the surface; thus, the electrical performance did not significantly deteriorate. Through this study, the relationship between the adhesion strength and electrical performance was identified. This study will provide useful information for analyzing the performance of flexible electrodes in the commercialization of flexible electronic devices in the future.

파형 웨브주름 보의 휨성능에 관한 실험적 연구 (Experimental Study on Flexural Structural Performance of Sinusoidal Corrugated Girder)

  • 김종성;채일수
    • 한국강구조학회 논문집
    • /
    • 제27권6호
    • /
    • pp.503-511
    • /
    • 2015
  • 강구조물에서 장스팬의 경우, 일반적으로 스티프너로 보강된 플레이트거더를 많이 사용하는데, 보(girder)의 춤이 크고 웨브의 폭이 좁은 단면을 선택하는 경우는, 웨브가 세장해져서 면외좌굴이 문제가 된다. 이를 해결하기 위한 방안으로, 이 연구에서는 국내에서도 공장, 창고건물을 중심으로 많이 사용되고 있는, 춤이 큰 주름 웨브 보를 휨재로 사용했을 때, 그 적용가능성을 판단하기 위하여, 그 선행작업으로, 주름 웨브(파형, Sinusoidal)를 가진 H형 단면보의 재하실험을 실시하였다. 평판웨브 P-4.5실험체에 비해서 주름웨브 CP-2.3실험체는 최대 휨내력은 12% 부족했지만, CP-3.2 실험체는 약 24% 내력상승이 나타났다. 이는 주름웨브 보는 평판보보다 불리한 판폭두께비를 가진 경우에도 충분한 내력확보가 가능함을 의미한다. 그리고 유로코드(EN 1993-1-5)에 의하여 산정된 휨 내력 및 전단내력을, 재하실험에 의한 휨내력과 KBC2009에 의한 전단내력을 비교하였다. 유로코드에서는 주름웨브의 판두께 증가는 휨성능 향상에 도움이 안 되며, 전단성능은 웨브 판두께와 주름 웨브의 형상에 민감함을 알았다.

Prepacked DFRCC 재료로 제작된 휨 부재의 휨 거동 및 내구성 평가 (Flexural behavior and durability evaluation of flexural members manufactured using prepacked DFRCC material)

  • 김장호;임윤묵;홍종석;이경민;김윤호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.57-60
    • /
    • 2006
  • The purpose of this study is to assess performance of prepacked DFRCC material compared with the DFRCC material which is made by using general mixing method. From 4r-point bending test, bond strength test and chlorine ion penetration test, flexural stress, -deflection relations, bond strengths, and durability assessment have been obtained. From the experiments, premixed DFRCC shows relatively good performance.

  • PDF

Evaluation of Field Calibration Test on Rail for Train Wheel Force Measurement

  • Sim, Hyoung-Bo;Yeo, Inho
    • International Journal of Railway
    • /
    • 제8권1호
    • /
    • pp.1-4
    • /
    • 2015
  • An accurate measurement of the train-track interaction forces is important for track performance evaluation. In the field calibration test as a wheel load measurement process, the calibration system creates a different boundary condition in comparison with that in the train wheel passage. This study aims to evaluate a reliability of the field calibration test in the process of wheel load measurement. Finite element models were developed to compare the deformed shapes, bending moment and shear force profiles on the rail section. The analysis results revealed that the deformed shapes and their associated bending moment profiles on the rail are significantly different in two numerical simulations of the calibration test and the train wheel load passage. However, the shear stress profile on the rail section of the strain gauge installation in the field was almost identical, which may imply that the current calibration test is sufficiently reliable.

180kV HVDC 해저케이블 기계적/전기적 특성 평가 (Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System)

  • 김남열;이태호;지봉기;이상진;김정년;전승익;윤희석;정수길;강채홍;안용호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

수중에서 박테리아 셀룰로오스 작동기의 굽힘 성능 (Bending Performance of Bacterial Cellulose Actuator under Water)

  • 전진한;박민우;김성준;김재환;오일권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.203-204
    • /
    • 2008
  • Bacterial Cellulose Actuator with biocompatible and biodegradable properties was newly developed as an electro-active biopolymer under water. The performance of the BC actuator was improved through Li treatment. The mechanical and chemical properties of BC membranes were measured such as the tensile test, proton conductivity. The surface morphology of the bacterial cellulose was observed by using SEM. The electromechanical bending responses under both direct current and alternating current excitations were investigated. In voltage-current test,the power consumption under dynamic excitation increases with increasing voltage. Present results show that the bacterial cellulose actuator can be a promising smart material and may possibly have diverse applications under water.

  • PDF

Comparison of steels via SMAW and MIG welding methods under industrial loads

  • Soy, Ugur
    • Steel and Composite Structures
    • /
    • 제11권3호
    • /
    • pp.225-232
    • /
    • 2011
  • In this study, the deflection and deformation behaviours of IPN80 steel beam and column were investigated under the different industrial loads. Single-sided welds were applied to IPN80 steel beams using shielded metal arc (SMAW) and metal inert gas welding (MIG) method in the form of T-type. After that, the performance of SMAW and MIG welded joints were identified using beam bending test under 500 and 3000 N loads. SMAW and MIG methods were compared with each other to understand the deflection and deformation behaviours of the welded steel structures. Lower deformation and deflection were obtained in MIG welded steel beams. The results show that, steel beams welded MIG method has higher load capacity than SMAW welded ones. MIG welding method is more reliable than the SMAW method for the combining performance and load capacity.

Experimental study on the fatigue performance of aluminum foam sandwich with 304 stainless steel face-sheet

  • Yan, Chang;Jing, Chuanhe;Song, Xuding
    • Steel and Composite Structures
    • /
    • 제39권3호
    • /
    • pp.229-241
    • /
    • 2021
  • This work focused on aluminum foam sandwich (AFS) with different foam core densities and different face-sheet thicknesses subjected to constant amplitude three-point bending cyclic loading to study its fatigue performance. The experiments were conducted out by a high frequency fatigue test machine named GPS-100. The experimental results showed that the fatigue life of AFS decreased with the increasing loading level and the structure was sensitive to cyclic loading, especially when the loading level was under 20%. S-N curves of nine groups of AFS specimens were obtained and the fatigue life of AFS followed three-parameter lognormal distribution well. AFS under low cyclic loading showed pronounced cyclic hardening and the static strength after fatigue test increased. For the same loading level, effects of foam core density and face-sheet thickness on the fatigue life of AFS structure were trade-off and for the same loading value, the fatigue life of AFS increased with aluminum foam core density or face-sheet thickness monotonously. Core shear was the main failure mode in the present study.

Structural performance of cold-formed steel column bases with bolted moment connections

  • Chung, K.F.;Yu, W.K.;Wang, A.J.
    • Steel and Composite Structures
    • /
    • 제5권4호
    • /
    • pp.325-340
    • /
    • 2005
  • This paper presents a thorough investigation into the structural performance of cold-formed steel column bases using double lipped C sections with bolted moment connections. A total of four column base tests with different connection configurations were carried out, and it was found that section failure under combined bending and shear was always critical. Moreover, the proposed column bases were demonstrated to be structurally efficient attaining moment resistances close to those of the connected sections. In order to examine the structural behaviour of the column base connections, a finite element model was established using shell and spring elements to model the sections and the bolted fastenings respectively. Both material and geometrical non-linearities were incorporated, and comparison between the test and the numerical results was presented in details. The design rules originally developed for bolted moment connections between lapped Z sections were adopted and re-formulated for the design of column base connections after careful calibration against the test data. Comparison on co-existing moments and shear forces at the critical cross-sections of the column bases was fully presented. It was shown that the proposed design and analysis method was structurally adequate to predict the failure loads under combined bending and shear for column bases with similar connection configurations.