• 제목/요약/키워드: Bell Mouth Inlet

검색결과 6건 처리시간 0.021초

입구 벨마우스 형상에 따른 냉장고 원심홴의 성능에 대한 수치적 분석 (Numerical analysis on the performance of centrifugal fans according to shapes of inlet bell-mouth in a refrigerator)

  • 김상현;허승;정철웅;김태훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.737-742
    • /
    • 2011
  • Because of complex structure of inlet and outlet flows, the performance of centrifugal fans used in a household refrigerator is affected by many parameters of duct system surrounding the fans. In this paper, the performance of a centrifugal fan is numerically analysed according to shapes of inlet bell-mouth. To improve performance of the centrifugal fan, some design parameters are selected for comparison. On a basis of these comparison, optimum shape of inlet bell-mouth is proposed to maximise the flow rate of the fan.

  • PDF

벨 마우스 흡입구 보호망에 의한 전압력 손실영향 연구 (Study on the Effect of Total Pressure Loss by Bell Mouth Inlet Screen)

  • 이창욱;최성만
    • 한국추진공학회지
    • /
    • 제25권6호
    • /
    • pp.29-35
    • /
    • 2021
  • 벨 마우스 흡입구는 압력 손실이 거의 발생하지 않으며 정확한 유량 계측이 가능하다는 장점이 있어 다양한 산업에서 적용되고 있다. 본 연구에서는 벨 마우스 흡입구의 벨 형태를 Long radius 형상으로 설계하였고 야외 환경에서 엔진 운용조건에 대해 흡입되는 공기의 압력강하가 발생되는 동시에 외부 물질에 의한 엔진 손상이 발생되지 않는 적합한 보호망의 격자 사이즈를 선정하였다. 보호망 설치로 인한 전압력 손실에 대해 전산 해석 및 실험 결과 획득한 두 가지 데이터 로부터 수정된 압력 강하 계수 방정식을 제시할 수 있었다.

펌프 흡수정내 발생된 보텍스에 대한 CFD 예측 (CFD Prediction on Vortex in Sump Intake at Pump Station)

  • 박상언;노형운
    • 한국유체기계학회 논문집
    • /
    • 제10권4호
    • /
    • pp.39-46
    • /
    • 2007
  • In large pump station, vortex generation such as free-surface vortex and submerged vortex occurring around pump intake, or at bell-mouth inlet has been an important flow characteristics which should be considered always to keep away the suction of air-entrained or cavitated flow. In this study, a commercial CFD code was used to predict accurately the vortex generation for the specified intake design. These result shows the preliminary result of submerged vortex prediction for the Turbo-machinery Society of Japan Sump Test CFD standard model. At bottom wall, air volume fraction (red color) was found in a large scale to explain the submerged vortex generation at particular operation and configuration condition. And these indicate the free surface formation behind the bell mouth. Particularly, non-uniform approaching flow is a major parameter to govern the occurrence of the free-surface vortex. Futhermore the comparison between turbulence ($k-{\epsilon}$ & $k-{\omega}$ model) mode were executed in this study.

라이너가 있는 덕트의 소음방사 특성에 관한 수치적 연구 (A Numerical Study of Radiation Effect from Ducted Fans with Liners)

  • 임창우;정철웅;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1010-1015
    • /
    • 2002
  • Over the last few decades, noise has played a major role in the development of aircraft engines. The dominant noise is generated by the wake interactions of fan and downstream stator. Engine inlet and exhaust ducts are being fitted with liner materials that aid in damping fan related noise. In this paper, the radiation of duct internal noise from duct open ends with liners is studies via numerical methods. The linearized Euler's equations in generalized curvilinear coordinates are solved by the DRP scheme. The far field sound pressure levels are computed by the Kirchhoff integration method. Through comparison of sound directivity from bell-mouth duct with and without liners, it is shown that radiation from engine inlet is affected by liner effects or a soft wall boundary condition.

  • PDF

축류팬의 성능 평가 및 주변 유동 특성 (Performance and Flow Characteristics of Axial Fan)

  • 김재원;정윤영
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.972-981
    • /
    • 2000
  • Comprehensive work is done for flows by an axial fan by experimental research. The present model fan is used for air handling device for out-door unit of an air conditioner in home appliance. PIV(Particle Image Velocimetry) system and wind tunnel are adopted for measurements of flows and performance evaluation, respectively. Major experimental conditions are the installation depth of a fan into a bellmouth of it. Optimal position of a fan in an inlet guide tube is observed by examination of fan-performance and flows in both upstream and downstream of the fan. Consequently, in the case of the fan inserted in half depth into the inlet tube, the efficiency of fan shows its maximum value and flow patterns is also streamlined.

  • PDF

슬림형 룸에어컨 설계 인자에 관한 연구 (Numerical and Experimental Analysis of Design Parameters of a Slim Room Air-conditioner)

  • 신종진;이희술;김종문;민준기;오상경
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.95-100
    • /
    • 2005
  • Numerical simulations and experiments were conducted to analyze the design parameters for a slim room air-conditioner. These design parameters included a fan shape, a front panel, a scroll shape, a bell mouth, a distance between a fan and a heat exchanger, etc. Each design parameter was analyzed numerically and/or experimentally in terms of the flow rate and the sound pressure level, which should be the most influential factors for developing the slim room air-conditioner. The fan with a uniform height showed a better performance than that with a linearly varying height. It is recommended to use a front grill rather than a front panel according to sound pressure levels since the front panel itself is a huge resistance to the inlet flow. A redesigned scroll shape by changing the rotational direction of a fan also contributed a lot to lowering the sound pressure level. There existed a distance between a fan and a heat exchanger, where flow rates increased effectively.