• Title/Summary/Keyword: Before-After Study

검색결과 17,065건 처리시간 0.044초

Segmental Liver Stiffness Evaluated with Magnetic Resonance Elastography Is Responsive to Endovascular Intervention in Patients with Budd-Chiari Syndrome

  • Peng Xu;Lulu Lyu;HaitaoGe;Muhammad Umair Sami;Panpan Liu;Chunfeng Hu;Kai Xu
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.773-780
    • /
    • 2019
  • Objective: To assess segmental liver stiffness (LS) with MRI before and after endovascular intervention in patients with Budd-Chiari syndrome (BCS). Materials and Methods: Twenty-three patients (13 males and 10 females; mean age, 42.6 ± 12.6 years; age range, 31-56 years) with BCS as a primary liver disease were recruited for this study. Two consecutive magnetic resonance elastography (MRE) examinations were performed before the endovascular treatment. Fifteen patients who underwent endovascular intervention treatment also had follow-up MRE scans within three days after the procedure. LS was measured in three liver segments: the right posterior, right anterior, and left medial segments. Inter-reader and inter-exam repeatability were analyzed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Segmental LS and clinical characteristics before and after the intervention were also compared. Results: Within three days of the endovascular intervention, all three segmental LS values decreased: LS of the right posterior segment = 7.23 ± 0.88 kPa (before) vs. 4.94 ± 0.84 kPa (after), LS of the right anterior segment = 7.30 ± 1.06 kPa (before) vs. 4.77 ± 0.85 kPa (after), and LS of the left medial segment = 7.22 ± 0.87 kPa (before) vs. 4.87 ± 0.72 kPa (after) (all p = 0.001). There was a significant correlation between LS changes and venous pressure gradient changes before and after treatments (r = 0.651, p = 0.009). The clinical manifestations of all 15 patients significantly improved after therapy. The MRE repeatability was excellent, with insignificant variations (inter-reader, ICC = 0.839-0.943: inter-examination, ICC = 0.765-0.869). Bland-Altman analysis confirmed excellent agreement (limits of agreement, 13.4-19.4%). Conclusion: Segmental LS measured by MRE is a promising repeatable quantitative biomarker for monitoring the treatment response to minimally invasive endovascular intervention in patients with BCS.

Mandibular orthopedic repositioning appliance(MORA)가 배근력에 미치는 영향에 관한 연구 (A Study on the Effect of Mandibular Orthopedic Repositioning Appliance (MORA) on Back Muscle Strength)

  • 현기용;이승우
    • Journal of Oral Medicine and Pain
    • /
    • 제10권1호
    • /
    • pp.113-124
    • /
    • 1985
  • In order to observe the effect of mandibular orthopedic repositioning appliance (MORA) on body strength, the author measured back muscle strength with Digital Back Muscle DYNAMOMETER (TAKEI KIKI KOGYO Co., Tokyo, Japan) before MORA, 15 days after and 30 days after MORA in 12 men and then analysed them statistically. The subjects were weight-lifting athletes of Seoul Athletic High School without dysfunction of masticatory system. MORA was fabricated at 1.0-1.5rnm isotonically closed position (Myocentric Occlusion Position) from mandibular rest position (Myocentric Rest Position) using Myo-monitor (MyoTronics Research Inc., Seattle, Washington, USA) and-SVT C-II (Tokyo Shizaisha Inc., Tokyo, Japan). The results were as follows : 1. The mean of back muscle strength before MORA was 150 kg, that of 15 days after MORA was 165 kg (4.43% increase than before), and that of 30 days was 175 kg (10.76% increase than before). 2. There was a significant difference among back muscle strength before MORA, 15 days after and 30 days after MORA (P<0.01: repeated measures one-way ANOVA). 3. According to the result of determining mandibular position for MORA fabrication, mandibular rest position after relaxation with Myo-monitor was 3.2mm lower, 1.0mm posterior, and 0.5 mm left from centric occlusion. And the mean of the amount of lateral deviation was 0.7 mm.

  • PDF

국부상의치의 전해연마에 따른 SLS 3D 프린터의 적합성 평가 (Assessment of the fit of partial frame fabricated by SLS 3D printer)

  • 박영대;강월
    • 한국치위생학회지
    • /
    • 제19권6호
    • /
    • pp.1067-1075
    • /
    • 2019
  • Objectives: The present study aimed to compare the accuracy of removable partial denture (RPD) frameworks fabricated by selective laser sintering (SLS) before and after electropolishing. Methods: A partially edentulous mandibular model was used as the working model. Scanning of the model was performed using a dental scanner. The framework was designed using CAD software. The metal framework was formed using an SLS 3D printer. 3D scans of the two fabricated prototypes produced before and after electropolishing were overlapped with reference data. The fit was calculated based on Root Mean Square (RMS). Fabrication accuracy was verified using the paired t-test to compare the discrepancy before and after electropolishing. Results: The mean (SD) values of RMS before and after electropolishing were 126.6 (34.19) and 75.86 (21.36), respectively. There was a statistically significant difference before and after electropolishing (p<0.05). Conclusions: Metal frameworks made with SLS 3D printers showed clinically acceptable fit after electropolishing.

자녀의 초등학교 입학 전후 어머니의 양육불안에 미치는 영향요인 분석 (An Analysis of the Influential Factors on Mother's Child-rearing Anxiety Before and After Their Children's Entrance into Elementary School)

  • 신수희
    • 한국보육지원학회지
    • /
    • 제15권6호
    • /
    • pp.21-40
    • /
    • 2019
  • Objective: The purpose of this study is to find the tendencies and differences of mother's child-rearing anxiety before and after their children enter into elementary school, to analyze the factors influencing child-rearing anxiety at each time, and thereby to seek a support plan at the time of transition. Methods: The subjects of this study were 181 mothers who participated in two surveys which were conducted before and after their child entered into elementary school. Results: Firstly, mother's child-rearing anxiety before and after their children's entrance into elementary school was at a middle level, but increased significantly when they experienced their children's transition to elementary school. Secondly, mother's child-rearing anxiety, before their children's entrance into elementary school, was influenced by private education, the collection of educational information, cognitive ability, whether or not to develop a work status change plan, and birth order sequentially. Thirdly, child-rearing anxiety after their children's entrance into elementary school was significantly influenced by child-rearing anxiety before their children's entrance into elementary school and the mother's employment. Conclusion/Implications: This study is meaningful in the point that it suggested the necessity for the cooperation between multiple systems, such as systematic and stepwise parenting education, the importance of offering information to educational institutions and local governments, and for work- family support policy to prioritize children in order to support children's successful transition into elementary school.

체중현수 트래드밀 훈련이 뇌졸중노인의 보행과 근활성에 미치는 영향 (The Efficacy of Treadmill Training with Body Weight Support on Ambulation and Muscle Activity with Elderly Chronic Stroke)

  • 김성학
    • 대한물리치료과학회지
    • /
    • 제11권2호
    • /
    • pp.27-37
    • /
    • 2004
  • The propose of the study was to evaluate the efficacy of the partial body weight support during treadmill training on the ambulation in elderly with chronic stroke. Fourteen hemiplegic volunteers participated and were divided into an experimental and control groups. In the experimental group, the body weight support during treadmill training was performed 3 times per week for 6 weeks. In the control group, usual treadmill training was applied. Before and after experiments, temporal-spatial gait parameters were measured. The date of 14 patients who carried out the whole experimental course were statistically analyzed. The results of the study were : 1. In the comparison of gait velocity before and after experiment, the gait velocity was significantly increased in the experimental group and the control group(p<.05). In the comparison of difference of the gait velocity between groups, there was not significant difference between the experimental group and the control group(p>.05). 2. In comparison of gait cadence before and after experiment, the gait cadence was significantly increased in both groups(p<.05). In the comparison of difference of the gait cadence between groups, there was not significant difference between the experimental group and the control group(p>.05). 3. In the comparison of step length before and after experiment, the step length was significantly increased in the experimental group and the control group(p<.05). In the comparison of difference of the step length between groups, there was not significant difference between the experimental group and the control group(p>.05). 4. In the comparison of vastus medialis root mean square(RMS) before and after experiment, the vastus medialis RMS was significantly increased in the experimental group(p<.05). In the comparison of vastus medialis root mean square(RMS) before and after experiment, the vastus medialis RMS was not significantly increased in the experimental group(p>.05). In the comparison of difference of the vastus medialis RMS between groups, there was not significant difference between the experimental group and the control group(p>.05). 5. In the comparison of latency of somatosensory evoke potential(SSEP) before and after experiment, the latency of SSEP was significantly increased in the experimental group(p<.05). In the comparison of latency of somatosensory evoke potential(SSEP) before and after experiment, the latency of SSEP was significantly decreased in the control group(p>.05). In the comparison of difference of the latency of SSEP between groups, there was not significant difference between the experimental group and the control group(p>.05). 6. In the comparison of functional ambulation profile(FAP) before and after experiment, the FAP was not significant difference in the experimental group and the control group(p>.05). In the comparison of difference of the FAP between groups, there was not significant difference between the experimental group and the control group(p>.05).

  • PDF

브로거 운동을 병행한 산전운동프로그램이 임산부의 허리 통증 및 균형에 미치는 영향 단일 사례 연구 (Effect of prenatal exercise program combined with Brugger's exercise on low back pain and balance in pregnant women: A single-subject study)

  • 김선민;장상훈
    • 대한물리치료과학회지
    • /
    • 제28권1호
    • /
    • pp.85-96
    • /
    • 2021
  • Background: The purpose of this study was to effect of prenatal exercise program combined with Brugger's exercise on low back pain and balance in pregnant women. Design: A Single-Subject Study. Methods: This study was applied to 28 weeks of pregnant women who complained of low back pain for a total of 4 weeks. A total of 10 prenatal exercise programs in this study consists of sessions, and each session was applied with a Bruger exercise for 1 minute before the start. For the fatigue and safety of pregnant women, a break for 1 minute was provided for each session and was conducted under the supervision of the therapist The visual analogue scale (VAS), Oswestry disability index (ODI), and static balance (BT-4) were measured to evaluate the pregnant women's low back pain and balance ability before and after the intervention Results: The change in back pain after the intervention was VAS 5 before the intervention, but the VAS gradually decreased at 4 weeks after the intervention. Reduced to VAS 2 after 4 weeks of intervention. The Oswestry Disability Index (ODI) was 54%, which was at the level of severe disability, but the dysfunction index gradually decreased 4 weeks after intervention, reaching 19% in 4 weeks, and there were no problems with daily life. As for the static balance ability, the sway area and the sway distance values gradually decreased after the intervention in both the eyes open and closed state, showing an improvement in the static balance ability of pregnant women after the intervention than before the intervention. Conclusion: The prenatal exercise program combined with Brugger's exercise was effective to improve low back pain and static balance in pregnant women. The result of this study may helpful as basic data for obstetric physical therapy.

Effects of Low-Dose Aspirin Therapy on Thermoregulation in Firefighters

  • McEntire, Serina J.;Reis, Steven E.;Suman, Oscar E.;Hostler, David
    • Safety and Health at Work
    • /
    • 제6권3호
    • /
    • pp.256-262
    • /
    • 2015
  • Background: Heart attack is the most common cause of line-of-duty death in the fire service. Daily aspirin therapy is a preventative measure used to reduce the morbidity of heart attacks but may decrease the ability to dissipate heat by reducing skin blood flow. Methods: In this double-blind, placebo-controlled, crossover study, firefighters were randomized to receive 14 days of therapy (81-mg aspirin or placebo) before performing treadmill exercise in thermal-protective clothing in a hot room [$38.8{\pm}2.1^{\circ}C$, $24.9{\pm}9.1%$ relative humidity (RH)]. Three weeks without therapy was provided before crossing to the other arm. Firefighters completed a baseline skin blood-flow assessment via laser Doppler flowmetry; skin was heated to $44^{\circ}C$ to achieve maximal cutaneous vasodilation. Skin blood flow was measured before and after exercise in a hot room, and at 0 minutes, 10 minutes, 20 minutes, and 30 minutes of recovery under temperature conditions ($25.3{\pm}1.2^{\circ}C$, $40.3{\pm}13.7%\;RH$). Platelet clotting time was assessed before drug administration, and before and after exercise. Results: Fifteen firefighters completed the study. Aspirin increased clotting time before and after exercise compared with placebo (p = 0.003). There were no differences in absolute skin blood flow between groups (p = 0.35). Following exercise, cutaneous vascular conductance (CVC) was $85{\pm}42%$ of maximum in the aspirin and $76{\pm}37%$ in the placebo groups. The percentage of maximal CVC did not differ by treatment before or after recovery. Neither maximal core body temperature nor heart rate responses to exercise differed between trials. Conclusion: There were no differences in skin blood flow during uncompensable heat stress following exercise after aspirin or placebo therapy.

양돈산업에 있어서 유비쿼터스 환경에서 온도 및 하중 센서에 의한 자동 분만 알림 시스템 개발 (Auto Dispatch Device of Parturition Beginning Signal by Temperature and a Load Sensor at Ubiquitous Circumstance in Pig Industry)

  • 이장희;백순화;연승호
    • Reproductive and Developmental Biology
    • /
    • 제33권3호
    • /
    • pp.139-146
    • /
    • 2009
  • This study tried to develop the system (device) that automatically notify a manager of condition just before and after farrowing to extend ubiquitous-based technology and to increase efficiency of delivery care and productivity by reducing human labor and time on standby when farrowing management is done in the difficult and hard working environment of farrowing such as night or holidays in field sand especially in pig industry. In this test, selected 10 gilts were executed timed artificial insemination and were set up each temperature sensor and load sensor to them 3 days before the estimated farrowing day and were observed the farrowing situation. This study was embodied the NESPOT-based (KT Corporation) monitoring system, the system to transmit data in real time by utilization of wireless LAN and the sensor module to apply the ubiquitous environment to them. And this study was observed the situation to automatically notify situations of 10 gilts that first bore just before and after farrowing. The result obtained the farrowing situations of them in real time by setup of the NESPOT-based monitoring system to check farrowing situation directly is as follow. The average time of the automatic notice about situation just before farrowing by the temperature sensor was 27.5 minutes before the beginning of farrowing (the expulsion time of a piglet). 6 of 8 pregnant gilts that first bore automatically were notified situations just before farrowing and the temperature sensors inserted into 2 ones before farrowing were omitted. (The automatic notice rate 75%) The average time of the automatic notice of situation just after farrowing by the load sensor was taken 46.5 minutes after the beginning of farrowing (the expulsion time of a first piglet). The average gestation period of 8 ones that first bore and were tested by the automatic notice of farrowing situation was 115.6 days. This result found that the automatic farrowing notice system by the temperature sensor is more efficient than the load sensor as the automatic farrowing alarm device and sanitary treatment and improvement of the omission rate were required.

자동차 시트 프레임의 구조 강도 해석에 관한 연구 (Study on Structural Strength Analysis of Automotive Seat Frame)

  • 김기선;김성수;김세환;조재웅
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.39-44
    • /
    • 2013
  • 자동차 부품 중 승차감이나 안전에 직접적으로 관련된 부분은 시트이다. 또한 이러한 여건을 만족시키면서 승객의 안전을 보장하는 충분한 강성과 강도를 가져야 한다. 자동차 시트는 3D 모델링 되었고, 전후 유격, 측면 유격 및 전후 모멘트 강도의 3가지 실험에 대하여 시뮬레이션으로서 구조해석을 하였다. 해석 결과, 전후 유격 시험에서는 $0.038^{\circ}$의 변형 각도의 값과 측면 유격 시험에서는 $0.04^{\circ}$의 변형 각도의 값이 각각 나타났다. 또한 전후 모멘트 강도시험에서는 전방 및 후방 하중 시에 최대의 전변형량 값이 각각 0.18946mm 및 3.2482mm로 나타났다. 본 연구결과는 자동차 시트 프레임의 과도한 변형 및 파괴가 없음으로서 승객의 안전을 보장하는 충분한 강성과 강도를 검증할 수 있었다.

Bruxism과 악관절(顎關節) 기능장애자(機能障碍者)의 치료(治療)에 관(關)한 근전도학적(筋電圖學的) 연구(硏究) (AN ELECTROMYOGRAPHIC STUDY ON THE TREATMENT OF BRUXISM AND TEMPOROMANDIBULAR JOINT DYSFUNCTION PATIENTS)

  • 노창섭;최부병
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.85-94
    • /
    • 1984
  • The purpose of this study was to investigate treatment effectiveness of TENS and bite plane for bruxism and TMJ dysfunction patients. The electromyograms were made on males aged 23 to 25 with sound stomatognathic system, 5 males bruxism aged 24 to 27, and 1 male and 4 females TMJ dysfunction patients (right TMJ pain) aged 14 to 33. The electromyographic study was limited to the middle of masseter muscle and anterior temporal muscle. The electromyographic study was carried out with 8-channel EM2 (Myotronics Research Inc.) and was taken 5 mandibular positions of clinical rest position, clench intercuspal position, clench protruded, cluch right, clench left. The 2 pairs of surface electrodes were used exactly, with the ear lobe as reference point. The recording were subjected to determine the mean voltage. The results were as follows; 1. In the clinical rest position, the muscle activities of bruxism and TMJ dysfunction patients were higher than those of normal at the before treatment, but that were lower or similar to those of normal at the TENS after and after bite plane wearing. 2. In the clench I.C.P., the muscle activities of TMJ dysfunction patients were decreased as the order of the before treatment, after TENS, after occlusal bite plane wearing, but those of bruxism were irregular. 3. In the clench right and the clench left, the muscle activities of the middle of masseter muscle of the non-working side of bruxism were higher than those of the working side at the before treatment and after TENS, but the muscle activities of after occlusal bite plane wearing were similar to those of the normal. 4. In the clench right and the clench left, the muscle activities of the middle of masseter muscle and anterior temporal muscle of the working side of TMJ dysfunction patients were higher than those of non-working side as like the normal at the before treatment, after TENS, and after occlusal bite plane wearing.

  • PDF