• Title/Summary/Keyword: Beat Signal

Search Result 137, Processing Time 0.03 seconds

A Study on the Separation of Fetal ECG from a Single Channel Abdominal ECG (단일채널 복부 심전도를 통한 태아 심전도 분리)

  • Park Kwang-Li;Lee Kyoung-Joung;Lee Jeon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.3
    • /
    • pp.198-205
    • /
    • 2005
  • In this paper, we proposed a new algorithm for the separation of fetal ECG from single channel abdominal ECG. The algorithm consists of a stage of demixing vector calculation for initial signal and a stage of fetal beat detection for the rest of signal. The demixing vector was obtained by applying independent component analysis technique to projected signals into time-frequency domain. For the test of this algorithm, simulation signals, De Lathauwer's data and some measured data, which was acquired from 8 healthy volunteers whose pregnant periods ranged from 22 weeks to 35 weeks and whose ages from 27 to 37, were used. For each data, the accuracy of fetal beat detection was $100\%$ and with the location of fetal beats, fetal heart rate variability and morphology could be offered. In conclusion, this proposed algorithm showed the possibility of fetal beat separation with a single channel abdominal ECG and it might be adopted to a fetal health monitoring system, by which a single channel abdominal ECG is acquired.

Heart Beat Interval Estimation Algorithm for Low Sampling Frequency Electrocardiogram Signal (낮은 샘플링 주파수를 가지는 심전도 신호를 이용한 심박 간격 추정 알고리즘)

  • Choi, Byunghun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.898-902
    • /
    • 2018
  • A novel heart beat interval estimation algorithm is presented based on parabola approximation method. This paper presented a two-step processing scheme; a first stage is finding R-peak in the Electrocardiogram (ECG) by Shannon energy envelope estimator and a secondary stage is computing the interpolated peak location by parabola approximation. Experimental results show that the proposed algorithm performs better than with the previous method using low sampled ECG signals.

Implementation of the Wavelength-Swept-Source and Signal Processing for the Frequency Domain Optical Coherence Tomography (주파수영역 광 간섭 단층촬영 시스템을 위한 파장가변 광원 및 신호처리계의 구현)

  • Lee, Eung-Je;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.309-316
    • /
    • 2007
  • We demonstrate the wavelength swept source and signal processing for the frequency domain optical coherence tomography. The laser output performance is improved by using a semiconductor optical amplifier with a booster amplifier. The laser generates 14 mW of average power of which wavelength shift in the lasing spectral shape is compensated. Adopting a Fabry-Perot etalon and digital signal processing, the broadening of the beat frequency due to the variance of wavelength-sweep-velocity is calibrated. The optical coherence tomography system shows 154.4 kHz of axial scanning speed, 0.95mm of depth range, and $12{\pm}0.37{\mu}m$ of axial resolution.

Development of a High-Resolution Electrocardiography for the Detection of Late Potentials (Late Potential의 검출을 위한 고해상도 심전계의 개발)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.449-458
    • /
    • 1996
  • Most of the conventional electrocardiowaphs foil to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography(HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as vontricular late potentials(LP). We have developed a HRECG using uncorrected XYZ lead for the detection of LPs. The overall gain of the amplifier is 4000 and the bandwidth is 0.5-300Hz without using 60Hz notch filter. Three 16-bit A/D converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to a PC via a DMA-controlled, optically-coupled serial communication channel. In order to further reduce the noise, we implemented a signal averaging algorithm that averaged many instances of aligned beats. The beat alignment was carried out through the use of a template matching technique that finds a location maximizing cross-correlation with a given beat tem- plate. Beat alignment error was reduced to $\pm$0.25ms. FIR high-pass filter with cut-off frequency of 40Hz was applied to remove the low frequency components of the averaged X, Y, and Z signals. QRS onset and end point were determined from the vector magnitude of the sigrlaIL and some parameters needed to detect the existence of LP were estimated. The entire system was designed for the easy application of the future research topics including the optimal lead system, filter design, new parameter extraction, etc. In the developed HRECG, without signal averaging, the noise level was less than 5$\mu$V$_rms RTI$. With signal averaging of at least 100 beats, the noise level was reduced to 0.5$\mu$V$_rms RTI$, which is low enough to detect LPs. The developed HRECG will provide a new advanced functionality to interpretive ECG analyzers.

  • PDF

Design and Performance Analysis of Zoom-FFT Based FMCW Radar Level Meter (Zoom-FFT 기반 FMCW 레이더 레벨미터의 설계 및 성능분석)

  • Sanjeewa, Nuwan;Kim, Won-Ho
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.38-44
    • /
    • 2014
  • This paper presents design of a FMCW (Frequency Modulated Continuous Wave) level meter as well as simulation result of the designed system. The system is designed to measure maximum range of 20m since FMCW radar can be used for measuring short range distance. The distance is measured by analyzing the beat signal which is generated as result of mixing transmitting signal with the reflected received signal. The Fast Fourier Transform is applied to analyze the beat signal for calculating the displacement and Zoom FFT technique is used to minimize measurement error as well as increase the resolution of the measurement. The resolution of the measurement of the designed system in this paper is 2.2mm and bandwidth of 1.024GHz is used for simulation. Thus the simulation results are analyzed and compared in various conditions in order to get a comprehensive idea of frequency resolution and displacement resolution.

Frequency Stabilization of He-Ne laser using One Chip Micro-Processor (1칩 마이크로 프로세서를 이용한 He-Ne 레이저의 주파수 안정화)

  • 최현승;엄태봉;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.102-105
    • /
    • 2000
  • A simple digital control system has been developed for the frequency stabilization of an internal mirror He-Ne laser. The system is based on one chip microprocessor with embedded Basic interpreter. To stabilize the laser output frequency, the signal such as power difference or beat frequency between two modes is supplied and processed by a microprocessor, and control signal is fed to the heating coil would round the laser tube for adjusting the spacing of the laser cavity mirror. Newly developed frequency stabilization system is totally digitized. The system and the frequency stability performance are briefly described.

  • PDF

Robust Adaptive Law in Adaptive Mechanism Showing Chaotic Phenomenon (혼돈 현상을 보이는 적응기구에서의 강인한 적응법칙)

  • 전상영;임화영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.7
    • /
    • pp.1414-1420
    • /
    • 1994
  • In this paper the existence of chaotic signal is probed in adaptive dead beat control law for nonlinear dynamic system. These chaotic signal makes the system unstable and difficult to control, but it broaden the range of application, confirms the robustness of system and gives a lot of information. Considering of low correlation between chaotic signals, robust adaptive control method which uses for parameter estimation is proposed. With this algorithm the parameters converges stable rapidly. Finally the superiority of it is proved by computer simulation.

  • PDF

Development of Portable Cadiovascular Signal Analysis System (휴대형 심혈관 신호해석장치의 개발)

  • Lee, D.J.;Lee, J.W.;Kim, H.S.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.663-665
    • /
    • 1998
  • The purpose of this paper is development of portable cardiovascular signal processing device. Beat-to-beat fluctuation in heart rate, respiration, and blood pressure have been known to be meditated by autonomic nervous system activities convergent on various effector organs. This system consists of data acquisition module, main data processing module and graphic LCD module. The data acquisition module is developed for data aquisition, data multiplexing and interfacing with main data processing system. And, main data processing module is developed for data storing, data processing and interfacing with graphic LCD module. The main processing system is based on 32-bit microprocessor.

  • PDF

ft Study on the Dither Random Noise for Improving the Bias Stability of Ring Laser Gyroscope (링레이저 자이로의 바이어스 안정도 개선을 위한 몸체진동 잡음 연구)

  • Shim, Kyu-Min;Kim, Cheon-Joong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.11
    • /
    • pp.1065-1073
    • /
    • 2006
  • In this paper we confirm the relation between the phases and phase errors of the beat signal at the lock-in region of the amplitude modulation type ring laser gyroscope by numerical calculation. Based on this facts, we, numerically, study the envelopes and magnitudes of the dither noise for statistically summing out the beat signal phase error, and we, experimently, confirm these numerical results. As a result, we find that the dither noise requires the increase gradient and the decrease gradient of the dither amplitudes, and those gradients should be combined with white noise. The magnitude of the dither noise which is satisfied with these requirements should be more than 5 percents of the average dither amplitude.

Improvement of Fetal Heart Rate Extraction from Doppler Ultrasound Signal (도플러 초음파 신호에서의 태아 심박 검출 개선)

  • Kwon, Ja Young;Lee, Yu Bin;Cho, Ju Hyun;Lee, Yoo Jin;Choi, Young Deuk;Nam, Ki Chang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.328-334
    • /
    • 2012
  • Continuous fetal heart beat monitoring has assisted clinicians in assuring fetal well-being during antepartum and intrapartum. Fetal heart rate (FHR) is an important parameter of fetal health during pregnancy. The Doppler ultrasound is one of very useful methods that can non-invasively measure FHR. Although it has been commonly used in clinic, inaccurate heart rate reading has not been completely resolved.. The objective of this study is to improve detection algorithm of FHR from Doppler ultrasound signal with simple method. We modified autocorrelation function to enhance signal periodicity and adopted adaptive window size and shifted for data segment to be analysed. The proposed method was applied to real measured data, and it was verified that beat-to-beat FHR estimation result was comparable with the reference fetal ECG data. This simple and effective method is expected to be implemented in the embedded system.