• Title/Summary/Keyword: Bearing Bar

Search Result 134, Processing Time 0.026 seconds

Experimental investigation on UHPC beams reinforced with GFRP and steel rebars and comparison with prediction equations

  • Parvin, Yousef Abbasi;Shaghaghi, Taleb Moradi;Pourbaba, Masoud;Mirrezaei, Seyyed Saeed;Zandi, Yousef
    • Advances in concrete construction
    • /
    • v.14 no.1
    • /
    • pp.45-55
    • /
    • 2022
  • In this article, the flexural and shear capacity of ultra-high-performance fiber-reinforced concrete beams (UHPFRC) using two kinds of rebars, including GFRP and steel rebars, are experimentally investigated. For this purpose, six UHPFRC beams (250 × 300 × 1650 mm) with three reinforcement ratios (ρ) of 0.64, 1.05, and 1.45 were constructed using 2% steel fibers by volume. Half of the specimens were made of UHPFRC reinforced with GFRP rebars, while the other half were reinforced with conventional steel rebars. All specimens were tested to failure in four-point bending. Both the load-deformation at mid-span and the failure pattern were studied. The results showed that utilizing GFRP bars increases the flexural strength of UHPFRC beams in comparison to those made of steel bars, but at the same time, it reduces the post-cracking strain hardening. Furthermore, by increasing the percentage of longitudinal bars, both the post-cracking strain hardening and load-bearing capacity increase. Comparing the experiment results with some of the available equations and provisions cited in the valid design codes reveals that some of the equations to predict the flexural strength of UHPFRC beams reinforced with conventional steel and GFRP bars are reasonably conservative, while Khalil and Tayfur model is un-conservative. This issue makes it essential to modify the presented equations in this research for predicting the flexural strength of UHPFRC beams using GFRP bars.

A Study on Methodology for Improvement of Bond of FRP reinforcement to Concrete (초단유리섬유(milled glass fibers)와 에폭시 혼합물을 이용한 FRP 보강근 표면성형기법 연구)

  • Moon, Do-Young;Sim, Jongsung;Oh, Hongseob
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.775-785
    • /
    • 2006
  • This study focused on the development of surface deformations of GFRP rebars with a better bond characteristic for reinforcing concrete, and simultaneously, of GFRP rebars with more simple and economic production process. This research paper describes a development and bond performance of GFRP rebar with molded deformations, which is composed of polymer resin and milled glass fiber. To determine proper mix ration of milled fibers, material test of hardened epoxy and pullout tests of GFRP rebar with various mix ratio were conducted. The test results indicate that the new strategy of using a mixture of epoxy resin and milled fiber could be successfully applied to a surface structure of GFRP rebar to enhance bond with concrete. The bearing resistance of the ribs was further enhanced by the milled fibers at mechanical and environmental loading state.

Evaluation of Mechanical Joint Structural Performance through Actual Performance Testing of PC Connections (PC 접합부의 실물 성능실험을 통한 기계식이음 구조성능 평가)

  • Kim, Jae Young;Kim, Yong Nam;Seo, Min Jung;Kim, Beom Jin;Kim, Sung Jig;Lee, Kihak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.129-139
    • /
    • 2024
  • In this study, the SBC system, a new mechanical joint method, was developed to improve the constructability of precast concrete (PC) beam-column connections. The reliability of the finite element analysis model was verified through the comparison of experimental results and FEM analysis results. Recently, the intermediate moment frame, a seismic force resistance system, has served as a ramen structure that resists seismic force through beams and columns and has few load-bearing walls, so it is increasingly being applied to PC warehouses and PC factories with high loads and long spans. However, looking at the existing PC beam-column anchorage details, the wire, strand, and lower main bar are overlapped with the anchorage rebar at the end, so they do not satisfy the joint and anchorage requirements for reinforcing bars (KDS 41 17 00 9.3). Therefore, a mechanical joint method (SBC) was developed to meet the relevant standards and improve constructability. Tensile and bending experiments were conducted to examine structural performance, and a finite element analysis model was created. The load-displacement curve and failure pattern confirmed that both the experimental and analysis results were similar, and it was verified that a reliable finite element analysis model was built. In addition, bending tests showed that the larger the thickness of the bolt joint surface of the SBC, the better its structural performance. It was also determined that the system could improve energy dissipation ability and ductility through buckling and yielding occurring in the SBC.

An Experimental Study on the Behavior of the Perforated Rib Connector with Shearing Bars (전단구속철근을 배치한 유공강판 전단연결재에 관한 실험적 연구)

  • Kim, Sung-Chil;Kim, Young-Ho;Yu, Sung-Kun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.175-182
    • /
    • 2006
  • In the design of composite structures, shear connectors such as headed stud, channel, perforated plate, etc, are commonly used to transfer longitudinal shear forces across the steel-concrete interface. Many researches have been conducted to improve the characteristics of different types of shear connector. This paper presents the results of 11 push-out tests performed on the new perforated rib connectors with shearing bars embedded in concrete slab under static loads. The results obtained from these tests are as following : 1) The bearing plate welded on both sides of perforated rib plate improves the stiffness and strength. 2) The capacity of perforated connectors is influenced primarily by the transverse reinforcements and shearing bars.

Pullout Characteristics of MC Anchor in Shale Layer (셰일지반에 설치된 MC앵커의 인발특성)

  • Lee, Bongjik;Kim, Josoon;Lee, Jongkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.53-61
    • /
    • 2012
  • In this study, the research on MC anchor has been developed as composite type has done. MC anchor exerts bearing pressure on pre-bored hole where the end fixing device is expanded. Therefore, the uplift capacity is to be increased and it has the characteristics that the anchor body is not eliminated from the ground even if the grouting is not carried out properly. Furthermore, it reduces the loss of tension and raises the construction availability by inserting the reinforced bar as well as the anchor cable, while it can improve the long-term stability because the nail is expected to play the role when the loss of the anchor cable is occurred in a long-term. However, because the resistance mechanism of the compound anchor such as MC anchor is different from friction anchor, the estimation method of the uplift capacity by the frictional force of the ground and the grout is not proper. Particularly, in domestic cases, the problem to overestimate or underestimate the uplift capacity is expected because the design method considering the soil characteristics about the compound anchor has not been developed. Therefore, in this study, in order to evaluate the characteristics of MC anchor and a kind of compound anchor, we measured the uplift, the tension and the creep by nine anchors tests in shale ground that the fluctuation of the strength is great. In addition, we analyzed the test result comparing to the result of the general friction anchor and evaluated the characteristics of MC anchor movement to gather the results. As a result of the test, we found the effect that the uplift capacity is increased in shale ground comparing to the general friction anchor.

Experimental Study for Improving Method of Load Bearing and Spalling Prevention of 100 MPa High Strength Concrete Column (100 MPa급 고강도 콘크리트 기둥의 폭렬방지 및 하중지지력 향상방안에 관한 실험적 연구)

  • Cho, Bum-Yean;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu;Kim, Kyeong-Ok
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.78-84
    • /
    • 2012
  • In this study, we have conducted a fire resistance experiment under loading condition on standard fire to evaluate the fire resistance performance according to applying reinforcement of methods for reinforcing the lateral confinement of reinforced bars (Wire Rope) and fire resistance reinforcement (Fiber-Cocktail) for 100 MPa high strength concrete column. In the result of the experiment, in case of the test objects applied by hoop, it has been shown as not possible to be applied as the fire resistance structure after satisfying the fire resistance performance for 43 minutes. In case of applying the wire rope as lateral confinement of reinforced bar, instead of hoop in identical volume ratio, it has been shown as possible to apply it to the buildings with under 4 floors after satisfying the fire resistance performance fro 69 minutes with any separate fire resistance process. Also, in case of applying with mixing wire rope method, instead of hoop, and Fiber-Cocktail mix method to prevent spall, it has been shown as possible to apply to the buildings with over 12 floors after satisfying the fire resistance performance for 180 minutes.

Influence of Bubble Sheet Applying Methods on Temperature of Exposed Joint Rebar at Wall Surface of Load-Bearing Wall Structure Building During Winter (동절기 벽식구조 건축물 벽부분의 버블시트 포설방법 변화가 이음부 노출철근의 온도에 미치는 영향)

  • Han, Cheon-Goo;Lee, Jea-Hyeon;Kim, Min-Sang
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.149-155
    • /
    • 2017
  • In this research, the surface covered curing method using the double-layered bubble sheet was evaluated. This double-layered bubble sheet has outstanding insulating performance with its low heat conductivity and high economic feasibility with its high durability. However, in the case of wall-typed building construction, the area of exposed rebar is curious on curing performance with the double-layered bubble sheet in spite of the double-layered bubble sheet showed favorable performance for slab. Therefore, in this research, regarding the actually constructed wall-typed apartment building, the most efficient curing method was suggested based on the evaluation of curing performance depending on temperature distribution depending on various location of covered or exposed rebar. As a result, the D method was determined as the most efficient curing method without any concern of early-age frost damage. However, by considering easiness of construction, the B method of covering the pieced double-layered bubble sheet on gap between rebars can be another option of desired result.

Development of interception capacity equations according to grate inlet types (빗물받이 형상에 따른 차집량 산정식 개발)

  • Choi, Sung Yeul;Eom, Kwangho;Choi, Seungyong;Cho, Jaewoong
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.10
    • /
    • pp.851-861
    • /
    • 2016
  • Recently, natural disasters, which are hard to predict and prevent, are rapidly increasing due to climate change worldwide. Particularly the damage scale of urban areas is increasing because of local torrential rainfall. In urban areas, the rain water cannot flow to pipes well due to the high percentage of impervious areas by the indiscriminate development. As a result, the inundation damage is getting higher in urban areas. So we need to characterize the interception of the grate inlets to ensure good drainage in impervious areas. But Korean installation criteria of grate inlets does not reflect road and drainage sector characteristics so the grate inlets do not function properly in many areas. In this study, we suggest the interception capacity equations about grate inlets through hydraulic experiments in various conditions. Therefore, the interception capacity changes are analyzed according to bearing bar slopes of grate inlets, grate inlet sizes and shapes and connecting pipe numbers. Though this, we developed the interception capacity equations about domestic grate inlets.

A study on structural performance of steel brackets in vertical shaft connected to double-deck tunnel (복층터널 연결 수직구용 철재브래킷 구조성능 연구)

  • Shin, Young-Wan;Min, Byeong-Heon;Nam, Jung-Bong;Lee, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.3
    • /
    • pp.363-375
    • /
    • 2019
  • Since the double-deck tunnel is deeply constructed in the city, it is necessary to secure the installation space of air supply and exhaust, escape passage stairs, elevator, distribution facilities and connection tunnels in the vertical shaft for the double-deck tunnel. Also, in order to minimize the effect of construction on adjacent area, it is necessary to construct the concrete structures at high speed in vertical shaft after tunnel excavation. Therefore, the slabs and the stairs in vertical shaft are needed to be constructed using precast concrete, and the rapid construction techniques of bracket for supporting the inner precast structure are needed. The bracket installation methods include cast-in-place concrete, precast concrete and steel. In this study, the improvement of the steel brackets with good economical efficiency and good workability was carried out in consideration of the improvement of the construction speed. We have developed a new bracket that is optimized through bracket shape improvement, anchor bolt position adjustment and quantity optimization. As a result of the structural performance test, it was confirmed that the required load supporting capacity was secured. As a result of structural performance test for bar type anchor bolt and bent anchor anchor bolt, it was confirmed that the required load carrying capacity was secured and that the load bearing capacity of bent anchor bolt was large.

The Geochemistry of Copper-bearing Hydrothermal Vein Deposits in Goseong Mining District (Samsan Area), Gyeongsang Basin, Korea (경상분지내 삼산지역 열수동광상에 관한 지화학적 연구)

  • Choi, Sang Hoon;So, Chil Sup;Kweon, Soon Hag;Choi, Kwang Jun
    • Economic and Environmental Geology
    • /
    • v.27 no.2
    • /
    • pp.147-160
    • /
    • 1994
  • Copper-bearing hydrothermal vein mineralization of the Samsan area was deposited in two stages (I and II) of quartz-calcite-sulfide veins which fill fissures in Cretaceous volcanic and sedimentary rocks of the Gyeongsang basin. The major ore minerals, chalcopyrite and sphalerite, together with pyrite, galena, hematite, and minor sulfosalts, occur with epidote and chlorite as gangue minerals in stage I quartz veins. Chlorite geothermometry, fluid inclusion and stable isotope data indicate that copper ore was deposited mainly at temperatures between $330^{\circ}C$ and $280^{\circ}C$ from fluids with salinities between 12 and 3 equiv. wt % NaCl. Evidence of fluid boiling indicates a range of pressures from ${\leq}100$ to 200 bars bars. Within ore stage I there was an apparent decrease in ${\delta}^{34}S$ values of $H_{2}S$ with paragenetic time, from 8.0 to 2.3 per mil. This pattern was likely achieved through progressive increases in activity of oxygen accompanying boiling and mixing. In the early part of the first stage, the high temperature, high salinity fluids gave way to progressively cooler and more dilute fluids of the late parts in the first stage and of the second stage. There is a systematic decrease in calculated ${\delta}^{18}O_{water}$ values with decreasing temperature in the Samsan hydrothermal system, from values of -86 per mil for early portion of stage I through -5.9 per mil for late portion of stage I to -6.3 per mil for stage II. The ${\delta}D$ values of fluid inclusion waters also decrease with paragenetic time from -76 per mil to -86 per mil. These trends combined with mineral paragenesis and fluid inclusion data are interpreted to indicate progressive cooler, more oxidizing meteoric water inundation of an early exchanged meteoric hydrothermal system.

  • PDF