• Title/Summary/Keyword: Beam source

Search Result 1,019, Processing Time 0.029 seconds

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

A Multi-megawatt Long Pulse Ion Source of Neutral Beam Injector for the KSTAR

  • Chang, Doo-Hee;Seo, Chang-Seog;Jeong, Seung-Ho;Oh, Byung-Hoon;Lee, Kwang-Won;Kim, Jin-Choon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.719-720
    • /
    • 2004
  • A multi-megawatt long pulse ion source (LPIS) of neutral beam injector was developed for the KSTAR. Beam extraction experiments of the LPIS were carried out at the neutral beam test stand (NBTS). Design requirements for the ion source were 120 kV/65 A deuterium beam and a 300 s pulse length. A maximum ion density of $9.1310^{11}$ $cm^{-3}$ was measured by using electric probes, and an optimum arc efficiency of 0.46 A/kW was estimated with ion saturation current of the probes, arc power, and total beam area. An arcing problem, caused by the structural defect of decelerating grid supporter, in the third gap was solved by the blocking of backstream ion particles, originated from the plasma in the neutralizer duct, through the unnecessary spaces on the side of grid supporter. A maximum drain power of 1.5 MW (i.e. 70 kV/21 A) with hydrogen was measured for a pulse duration of 0.5 s. Optimum beam perveance was ranged from 0.75 to 0.85. An improved design of accelerator for the effective control of beam particle trajectory should provide higher beam perveance.

  • PDF

Evaluation of Velocity and Source Locations of Acoustic Signals in PSC Beam (AE기법을 이용한 PSC보의 음파속도 및 음원위치 산정)

  • Youn, Seok-Goo;Kim, Eun-Keum;Choi, Min-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.330-333
    • /
    • 2006
  • In this paper experimental tests were performed to evaluate velocities of the acoustic waves through prestressed concrete beam and source locations using AE technique. Seven AE sensors are mounted on the surface of 5m length test beam with equal spacing and using Schmidt Hammer AE events are made 18 locations. The velocities of AE signals are evaluated using the time differences of arrival times and the distances between the AE source loactions and the AE sensor locations. In addition, using the Least Square Method, the AE source locations are re-evaluated reversely using both of the arrival times and the velocities of AE signals. Test results show the average velocity of the AE signals is about 4,000m/sec and the velocity decreased with the increase of the trevalling times due to the effect of attenuation. Based on the estimation of the source locations, it is observed that the accuracy of source location is increased when the velocity of each AE sensor used rather than the average velocity.

  • PDF

EO performance of IPS cell on the inorganic films surface using DuoPIGatron ion source (유기박막표면에 DuoPIGatron 이온소스를 이용한 IPS 셀의 전기광학 특성)

  • Kim, Byoung-Yong;Hwang, Jeoung-Yeon;Kim, Sang-Hun;Han, Jung-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.89-90
    • /
    • 2006
  • Electro-optical (EO) characteristics of in-plane switching (IPS) cell on the polyimide surface using obliquely ion beam (IB) exposure as new ion beam (IB) type system (DuoPIGatrion ion source). A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the polyimide surface was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned IPS-cell on poly imide surface ; the stable VT curve in the ion-beam-aligned IPS cell on a poly imide (PI) surface with ion beam exposure using new type IB equipment was obtained. and the fast response time in the ion-beam-aligned IPS cell on a polyimide (PI) surface with ion beam exposure using new type IB equipment was obtained.

  • PDF

EO performance of TN cell on the inorganic films surface using DuoPIGatron ion source on NDLC thin film (무기박막표면에 DuoPIGatron 이온소스를 이용한 TN-LCD 셀의 전기광학 특성)

  • Kim, Byoung-Yong;Hwang, Jeoung-Yeon;Kim, Sang-Hun;Han, Jung-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.432-433
    • /
    • 2006
  • Electro-optical (EO) characteristics of twisted nematic (TN) - liquid crystal display (LCD) on the NDLC thin film using obliquely ion beam (IB) exposure as new ion beam (IB) type system (DuoPIGatrion ion source). A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the NDLC thin film was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned TN-cell on polyimide surface ; the stable VT curve in the ion-beam-aligned TN cell on the NDLC thin film with ion beam exposure using new type IB equipment was obtained. and the fast response time in the ion-beam-aligned TN cell on the NDLC thin film with ion beam exposure using new type IB equipment was obtained.

  • PDF

Development of a High Brightness Ion Beam Extraction System using Micro-size Aperture (마이크로 사이즈 인출구경을 이용한 고휘도 이온빔 인출 시스템 개발)

  • Kim Yoon-Jae;Park Dong-Hee;Jeong Hyeong-Seol;Hwang Yong-Seok
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.19-23
    • /
    • 2005
  • In order to develop a high brightness ion source using plasma, the ion beam extraction system with an aperture of $100{\mu}m$ in diameter has been designed and constructed. It is observed that over 500nA of He ion beam current can be extracted. With such an optimized condition, $\~10^3\;A/cm^2sr$ beam brightness can be measured by emittance scanner, which is believed to be a promising result for developing next generation FIB.

  • PDF

Development of a Beam Source Modeling Approach to Calculate Head Scatter Factors for a 6 MV Unflattened Photon Beam

  • Park, So-Yeon;Choi, Noorie;Jang, Na Young
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.137-144
    • /
    • 2021
  • Purpose: This study aimed to investigate the accuracy of head scatter factor (Sc) by applying a developed multi-leaf collimator (MLC) scatter source model for an unflattened photon beam. Methods: Sets of Sc values were measured for various jaw-defined square and rectangular fields and MLC-defined square fields for developing dual-source model (DSM) and MLC scatter model. A 6 MV unflattened photon beam has been used. Measurements were performed using a 0.125 cm3 cylindrical ionization chamber and a mini phantom. Then, the parameters of both models have been optimized, and Sc has been calculated. The DSM and MLC scatter models have been verified by comparing the calculated values to the three Sc set measurement values of the jaw-defined field and the two Sc set measurement values of MLC-defined fields used in the existing modeling, respectively. Results: For jaw-defined fields, the calculated Sc using the DSM was consistent with the measured Sc value. This demonstrates that the DSM was properly optimized and modeled for the measured values. For the MLC-defined fields, the accuracy between the calculated and measured Sc values with the addition of the MLC scatter source appeared to be high, but the only use of the DSM resulted in a significantly bigger differences. Conclusions: Both the DSM and MLC models could also be applied to an unflattened beam. When considering scattered radiation from the MLC by adding an MLC scatter source model, it showed a higher degree of agreement with the actual measured Sc value than when using only DSM in the same way as in previous studies.

A Study on Thermal Analysis of Dual Beam Laser Welding of Thin Metal Sheet (박판의 이중 빔 레이저 용접에서 열유동 해석에 관한 연구)

  • 김재웅
    • Journal of Welding and Joining
    • /
    • v.15 no.4
    • /
    • pp.99-108
    • /
    • 1997
  • Analytical model for the temperature distribution and the cooling rate of weld in dual beam laser welding is presented for investigating the possibility of controling the cooling rate. The model is based on the solutions to the problem of heat flow due to the distributed and line heat sources for preheating and welding respectively in plates with finite thickness. The effects of beam power, beam distribution parameter, interbeam distance, and welding speed on the resulting temperature distribution and cooling rate are presented. The cooling rates of dual beam laser weld at the weld centerline under the investigated conditions are reduced to as one third of those of welds which were produced by single beam laser. And it appeared that the cooling rate of dual beam laser weld is strongly dependent on the process parameters of preheating laser beam power and welding speed.

  • PDF

An Analysis on the KSTAR neutral beam injection line (KSTAR 중성입자빔 수송라인 해석)

  • 임기학;김진춘;권경훈;조승연
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.556-564
    • /
    • 1999
  • The analysis on heat fluxed on and transmission efficiencies by the collimators of neutral beam injection lines in KSTAR tokamak device has been carried out. And a mathematical model describing non-Gaussian beam distribution profile has been established. A neutral beam injection device is composed of 3 separate ion sources and corresponding beam transport lines, which deal with 7.8 MW of beam power, respectively. The divergence angles of ion beam are $1.2^{\circ}$and $0.5^{\circ}$, in vertical and horizontal directions, respectively. The maximum normal heat load on source exit scraper is 9.1 kW/$\textrm{cm}^2$ and net beam transmission efficiency is ~28%. The effect of misalignment of ion source and scrapers on the scraper heat load and beam transmission also has been analyzed.

  • PDF