• Title/Summary/Keyword: Beam configuration

Search Result 379, Processing Time 0.025 seconds

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

Cone-beam computed tomography analysis of root and canal morphology of mandibular premolars in a Spanish population

  • Llena, Carmen;Fernandez, Jaime;Ortolani, Pablo Sebastian;Forner, Leopoldo
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.221-227
    • /
    • 2014
  • Purpose: This study aimed to investigate the clinical anatomy of lower premolar roots in a Spanish population by using cone-beam computed tomography (CBCT), correlating findings with patient gender and tooth type. Materials and Methods: Using 70 CBCT images, we evaluated 126 healthy, untreated, well-developed lower premolars. The number and morphology of roots and root canals, and the foramina number were assessed. Results for gender and tooth type were compared using the chi-squared and ANOVA tests. Results: The average length of teeth and roots was significantly higher in men (p=0.00). All 126 premolars had a single root. One canal was found in 83.3% of the premolars, with no gender or tooth type differences; Vertucci configuration types I and V were the most prevalent. The first premolars showed significantly greater variability than the second premolars (p=0.03). A single apical foramen was found in 89.7% of the premolars, with no differences by tooth type. Women had a significantly higher prevalence of two apical foramina than men (p=0.04). Some degree of curvature was observed in 65% of the premolars, with no differences by gender or tooth type. A root angle of more than $20^{\circ}$ was found in 12.98% of the premolars, without any differences by gender or tooth. Conclusion: All premolars were single-rooted. One canal had the most prevalent morphology. More variability in canal anatomy was found in the first premolars. Curvatures greater than $20^{\circ}$ were found at less than 5 mm from the apex.

Proximity of the mandibular molar root apex from the buccal bone surface: a cone-beam computed tomographic study

  • Kim, Dokyung;Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • Objectives: The purpose of this study was to evaluate the proximity of the mandibular molar apex to the buccal bone surface in order to provide anatomic information for apical surgery. Materials and Methods: Cone-beam computed tomography (CBCT) images of 127 mandibular first molars and 153 mandibular second molars were analyzed from 160 patients' records. The distance was measured from the buccal bone surface to the root apex and the apical 3.0 mm on the cross-sectional view of CBCT. Results: The second molar apex and apical 3 mm were located significantly deeper relative to the buccal bone surface compared with the first molar (p < 0.01). For the mandibular second molars, the distance from the buccal bone surface to the root apex was significantly shorter in patients over 70 years of age (p < 0.05). Furthermore, this distance was significantly shorter when the first molar was missing compared to nonmissing cases (p < 0.05). For the mandibular first molars, the distance to the distal root apex of one distal-rooted tooth was significantly greater than the distance to the disto-buccal root apex (p < 0.01). In mandibular second molar, the distance to the apex of C-shaped roots was significantly greater than the distance to the mesial root apex of non-C-shaped roots (p < 0.01). Conclusions: For apical surgery in mandibular molars, the distance from the buccal bone surface to the apex and apical 3 mm is significantly affected by the location, patient age, an adjacent missing anterior tooth, and root configuration.

An Experimental Study on the Strength of the Frame consisting of Concrete Filled Steel Tubular Column-H Beam under Alternately Repeated Horizontal Loading (반복하중을 받는 콘크리트충전 강관기둥-H형강보 골조의 강도에 관한 실험적 연구 -접합부 보강형식과 콘크리트충전에 따른 효과-)

  • Lee, Seong Do;Kim, Pil Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.641-655
    • /
    • 1998
  • It researched several jointing-methods of frame consisting of a concrete-filled steel tubular column and H-shaped beam. These beam-to-column connections is parameters to following: columns of square shape pipe infilled with or without concrete, joints assembled two types of diaphragm, outside-type and through-type. And it is testing that cyclically lateral loadings used hydraulic ram. In testing. we'll be on purposed to estimate the hysteretic behavior, strength and stiffness, energy absorption capacity, deformation capacity and failure configuration of each specimen. It is concluded that the frame specimens with outside-type are more stable and exhibit more energy absorption capacity compared with the through-type, in column of filled with concrete.

  • PDF

Development of a Vertical polarized Leaky-wave Waveguide Slot Array Antenna for Receiving the Ku-band Direct Broadcasting Satellite Signals

  • Lim, Gye-Jae
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.10-15
    • /
    • 2007
  • Small size and low profile antenna for mobile vehicular-top-mounted is needed in satellite communication services such as DBS, Satellite Internet and VSAT. In middle latitudes, the development of an array antenna which has the conformal, low profile and 45 degree beam tilted configuration, and has the high gain with sharp beamwidth, low sidelobe and low loss is required for Ku-band satellite communication. In this paper, in order to meet with these performances, an array antenna consisting of the vertical polarized waveguide longitudinal slots based on the leaky-wave mode of traveling wave antenna is proposed. An array antenna consisting of 16 leaky-wave elements is showing 30 dBi of gain, 4.9 degree of beamwidth, below than -20 dB of sidelobe level, 45 degree of beam tilt angle in center frequency. Feed network designed by waveguide cooperated feed shows good performance of wideband and low loss.

  • PDF

Observation of dispersion-like signal based on velocity-selsctive saturated absorption spectroscopy and frequency stabilization of diode laser (속도선택 포화흡수분광을 이용한 분산형 신호의 관측 및 반도체 레이저의 주파수안정화)

  • Park, Sang-Eon;Cho, Hyuck;Kwon, Taeg-Yong;yang, Sung-Hoon;Lee, Ho, Seung
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.158-164
    • /
    • 2001
  • We observed a velocity-selective saturated absorption spectrum when the pump beam intersects the probe beam at a finite angle with a saturated absorption spectroscopic configuration in the cesium vapor cell. And we also observed a dispersion-like signal by measuring the difference between two velocity-selective absorption spectra produced by two parallel probe beams intersected by one pump beam. The dispersion-like signal was changed with the crossing angle and the crossing position of the pump and probe beams and compared with the calculated result. The dispersion-like signal was used as a frequency discriminator, and the laser could be frequency-stabilized without any frequency modulation. As a result, the square root of Allan variance was $\sigma_y(\tau=1s)=7$\times10^{-12}$, for the sampling time of 1 s.of 1 s.

  • PDF

Analysis of C-shaped root canal configuration in maxillary molars in a Korean population using cone-beam computed tomography

  • Jo, Hyoung-Hoon;Min, Jeong-Bum;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the incidence of root fusion and C-shaped root canals in maxillary molars, and to classify the types of C-shaped canal by analyzing cone-beam computed tomography (CBCT) in a Korean population. Materials and Methods: Digitized CBCT images from 911 subjects were obtained in Chosun University Dental Hospital between February 2010 and July 2012 for orthodontic treatment. Among them, a total of selected 3,553 data of maxillary molars were analyzed retrospectively. Tomography sections in the axial, coronal, and sagittal planes were displayed by PiViewstar and Rapidia MPR software (Infinitt Co.). The incidence and types of root fusion and C-shaped root canals were evaluated and the incidence between the first and the second molar was compared using Chi-square test. Results: Root fusion was present in 3.2% of the first molars and 19.5% of the second molars, and fusion of mesiobuccal and palatal root was dominant. C-shaped root canals were present in 0.8% of the first molars and 2.7% of the second molars. The frequency of root fusion and C-shaped canal was significantly higher in the second molar than the first molar (p < 0.001). Conclusions: In a Korean population, maxillary molars showed total 11.3% of root fusion and 1.8% of C-shaped root canals. Furthermore, root fusion and C-shaped root canals were seen more frequently in the maxillary second molars.

An Analysis on the Degradation of Elevation Angle Accuracy Due to the Multi-Path Effect Using a Phased Array Antenna and the Beam Pattern Optimization to Minimize Its Degradation (위상배열 안테나를 활용한 다중 경로 효과에 의한 고각 정확도 열화 분석 및 열화 최소화를 위한 빔 패턴 최적화)

  • Kim, Young-Wan;Lee, JaeMin;Chae, Heeduck;Jin, Hyung-suk;Park, Jongkuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1036-1043
    • /
    • 2016
  • In this paper, an analysis about the elevation angle accuracy degradation of an APAR(Airport Precision Approach Radar) due to the multi-path effect using a phased array antenna was performed. An APAR installed around a runway of airport will be continuously affected in a runway surface of the fixed environment. In this paper, an analysis about the elevation angle accuracy degradation of APAR due to the multi-path effect of runway surface was conducted through a calculation of monopluse slope and sum/difference beam pattern analysis of array antenna. Also, a difference pattern for monopulse to minimize this degradation was optimized in an appropriate configuration to improve a elevation angle accuracy. Finally, a degree of improvement of elevation angle accuracy was confirmed by calculating a monopulse slope including the ground reflection after applying optimized difference patterns of array antenna.

The Pattern Improvement of Leaky-wave Slot Array Antenna for Satellite Communications (위성통신용 슬롯배열 누설파 안테나의 패턴 개선)

  • Lim, Gye-Jae;Park, Jong-Seo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.69-77
    • /
    • 2009
  • Small size and low profile antenna for mobile vehicular-top-mounted is needed in satellite communication services such as DBS, Satellite Internet and VSAT. In middle latitudes, the development of an array antenna which has the conformal, low profile and 45 degree beam tilted configuration, and has the high gain with sharp beamwidth, low sidelobe and low loss is required for Ka band satellite communication. In this paper, in order to meet with these performances, an array antenna consisting of the vertical polarized waveguide longitudinal slots based on the leaky-wave mode of traveling wave antenna is proposed. Especially, for the lower sidelobe level the radiation power control using a design method of the different slot width is proposed. An array antenna consisting of 32 leakywave elements is showing 34.4 dBi of gain, 3.6 degree of beamwidth, below than -25 dB of sidelobe level, 43 degree of beam tilt angle in center frequency 20.0 GHz. Feed network designed by waveguide cooperated feed shows good performance of wideband and low loss.

  • PDF

Array Configuration Analysis of Ka-Band Phase Array Antenna (Ka-대역 위상배열안테나 배열 구조 분석)

  • Kim, Youngwan;Kwon, Junbeom;Kang, Yeonduk;Park, Jongkuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.141-147
    • /
    • 2019
  • In this paper, a beam pattern performance analysis was performed according to number of array elements and spacing of the phase array antenna. The distance between array elements in an array structure design was reduced due to the electrical length of Ka-band, which increases the number of array elements in applying the aperture. If the number of elements reduce by widening the array distance, the grating lobes of the same size as the main beam will occur in visible region. If the number of array elements should be applied to a system where the number of array elements should be minimized, the analysis was performed on a plan to reduce the number of array elements and minimize degradation of performance, such as beam width and side lobe level.