• Title/Summary/Keyword: Beam Size

Search Result 1,705, Processing Time 0.032 seconds

Characterizing three-dimensional mixing process in river confluence using acoustical backscatter as surrogate of suspended sediment (부유사 지표로 초음파산란도를 활용한 합류부 3차원 수체혼합 특성 도출)

  • Son, Geunsoo;Kim, Dongsu;Kwak, Sunghyun;Kim, Young Do;Lyu, Siwan
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.3
    • /
    • pp.167-179
    • /
    • 2021
  • In order to characterize the mixing process of confluence for understanding the impacts of a river on the other river, it has been crucial to analyze the spatial mixing patterns for main streams depending on various inflow conditions of tributaries. However, most conventional studies have mostly relied upon hydraulic or water quality numerical models for understanding mixing pattern analysis of confluences, due to the difficulties to acquire a wide spatial range of in-situ data for characterizing mixing process. In this study, backscatters (or SNR) measured from ADCPs were particularly used to track sediment mixing assuming that it could be a surrogate to estimate the suspended sediment concentration. Raw backscatter data were corrected by considering the beam spreading and absorption by water. Also, an optical Laser diffraction instrument (LISST) was used to verify the method of acoustic backscatter and to collect the particle size distribution of main stream and tributary. In addition, image-based spatial distributions of sediment mixture in the confluence were monitored in various flow conditions by using an unmanned aerial vehicle (UAV), which were compared with the spatial distribution of acoustic backscatter. As results, we found that when acoustic backscatter by ADCPs were well processed, they could be proper indicators to identify the spatial patterns of the three-dimensional mixing process between two rivers. For this study, flow and sediment mixing characteristics were investigated in the confluence between Nakdong and Nam river.

Development of a Microspot Spectroscopic Ellipsometer Compatible with Atomic Force Microscope (원자힘 현미경 융합형 마이크로스폿 분광타원계 개발)

  • In, Sun Ja;Lee, Min Ho;Cho, Sung Yong;Hong, Jun Seon;Baek, In Ho;Kwon, Yong Hyun;Yoon, Hee Kyu;Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.5
    • /
    • pp.201-209
    • /
    • 2022
  • The previously developed microspot spectroscopic ellipsometer (SE) is upgraded to a microspot SE compatible with the atomic force microscope (AFM). The focusing optical system of the previous microspot SE is optimized to incorporate an AFM head. In addition, the rotating compensator ellipsometer in polarizer-sample-compensator-analyzer configuration is adopted in order to minimize the negative effects caused by beam wobble. This research leads to the derivation of the expressions needed to get spectro-ellipsometric constants despite the fact that the employed rotating compensator is far from the ideal achromatic quarter-wave plate. The spot size of the developed microspot SE is less than 20 ㎛ while the AFM head is mounted. It operates in the wavelength range of 190-850 nm and has a measurement accuracy of δΔ ≤ 0.05° and δΨ ≤ 0.02°, respectively. Fast measurement of ≤3 s/sp is realized by precisely synchronizing the azimuthal angle of a rotating compensator with the spectrograph. The microspot SE integrated with an AFM is expected to be useful in characterizing the structure and optical properties of finely patterned samples.

Frequency of Buccal Pits and Defective Buccal Pits in Mandibular Molars of Children and Adolescents (소아청소년의 하악 대구치에서 협측소와 및 협측소와 결함의 발생 빈도)

  • So Yung, Kim;Je Seon, Song;Ik-Hwan, Kim;Hyung-Jun, Choi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.253-263
    • /
    • 2022
  • A buccal pit is a prominent point-like depression that appears at the cervical end of the mandibular molar developmental grooves. A defective buccal pit can be defined as a buccal pit in which the continuity of the dentinoenamel junction is broken and the pit extends to the dentinal level. This study aimed to determine the frequency of buccal pits and defective buccal pits in un-erupted mandibular first and second molars using cone-beam computed tomography (CBCT). The analysis was performed on CBCT images taken from 417 Korean children and adolescents who visited the Department of Pediatric Dentistry, Yonsei University Dental Hospital between 2004 and 2020. Based on cross-sectional views of CBCT images, buccal pits were categorized into 4 classes according to the depth of the pits. The expression rate of the buccal pits was 29.1%. The prevalence of defective buccal pits was 7.9%. The buccal pits tended to develop bilaterally. To date, this is the most comprehensive study on the frequency of buccal pits with the largest sample size. This was the first attempt worldwide to analyze the depth of the buccal pit using CBCT images and to define a defective buccal pit worldwide.

An Evaluation of Crack Resistance for Slag Asphalt Concrete Mixture Using Steel Slag Aggregates (제강슬래그 골재를 사용한 슬래그 아스팔트 혼합물의 균열저항성 평가)

  • Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • With the continuous industrial development, not only natural resource depletion, waste generation, but also various weather conditions are becoming more frequent. Efforts are continuing to recycle industrial by-products to overcome the climate crisis and save resources. Slag is a representative by-product generated in the steel industry, and it is characterized by improving rutting resistance and moisture sensitivity by increasing strength and reducing deformation when used as a material for asphalt concrete. On the other hand, slag has expansion properties so it is used as a relatively low-value-added material such as embankment and refilling materials. In order to expand the application of slag, an experiment was conducted to evaluate the crack resistance of slag asphalt concrete pavement. As a result of the indirect tensile strength test, it was found that the asphalt mixture using slag aggregate showed a value 1.13 times higher than that of the general HMA with the same particle size, and the toughness was 1.17 units, improving crack resistance. In addition, it was found that the failure number of the 4-point beam fatigue experiment and the slag asphalt mixture was 20,409, which was more than doubled compared to the general HMA. Furthermore, Overlay Test showed a tensile load residual rate of 4 times or more, improving crack resistance to repeated fatigue. Accordingly, the use of slag aggregate will likely have various advantages in improving the performance of asphalt concrete pavement.

Functional beamforming for high-resolution ultrasound imaging in the air with random sparse array transducer (고해상도 공기중 초음파 영상을 위한 기능성 빔형성법 적용)

  • Choon-Su Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.361-367
    • /
    • 2024
  • Ultrasound in the air is widely used in industry as a measurement technique to prevent abnormalities in the machinery. Recently, the use of airborne ultrasound imaging techniques, which can find the location of abnormalities using an array transducers, is increasing. A beamforming method that uses the phase difference for each sensor is used to visualize the location of the ultrasonic sound source. We exploit a random sparse ultrasonic array and obtain beamforming power distribution on the source in a certain distance away from the array. Conventional beamforming methods inevitably have limited spatial resolution depending on the number of sensors used and the aperture size. A high-resolution ultrasound imaging technique was implemented by applying functional beamforming as a method to overcome the geometric constraints of the array. The functional beamforming method can be expressed as a generalized beam forming method mathematically, and has the advantage of being able to obtain high-resolution imaging by reducing main-lobe width and side lobes. As a result of observation through computer simulation, it was verified that the resolution of the ultrasonic source in the air was successfully increased by functional beamforming using the ultrasonic sparse array.

Verification of Gated Radiation Therapy: Dosimetric Impact of Residual Motion (여닫이형 방사선 치료의 검증: 잔여 움직임의 선량적 영향)

  • Yeo, Inhwan;Jung, Jae Won
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.128-138
    • /
    • 2014
  • In gated radiation therapy (gRT), due to residual motion, beam delivery is intended to irradiate not only the true extent of disease, but also neighboring normal tissues. It is desired that the delivery covers the true extent (i.e. clinical target volume or CTV) as a minimum, although target moves under dose delivery. The objectives of our study are to validate if the intended dose is surely delivered to the true target in gRT and to quantitatively understand the trend of dose delivery on it and neighboring normal tissues when gating window (GW), motion amplitude (MA), and CTV size changes. To fulfill the objectives, experimental and computational studies have been designed and performed. A custom-made phantom with rectangle- and pyramid-shaped targets (CTVs) on a moving platform was scanned for four-dimensional imaging. Various GWs were selected and image integration was performed to generate targets (internal target volume or ITV) for planning that included the CTVs and internal margins (IM). The planning was done conventionally for the rectangle target and IMRT optimization was done for the pyramid target. Dose evaluation was then performed on a diode array aligned perpendicularly to the gated beams through measurements and computational modeling of dose delivery under motion. This study has quantitatively demonstrated and analytically interpreted the impact of residual motion including penumbral broadening for both targets, perturbed but secured dose coverage on the CTV, and significant doses delivered in the neighboring normal tissues. Dose volume histogram analyses also demonstrated and interpreted the trend of dose coverage: for ITV, it increased as GW or MA decreased or CTV size increased; for IM, it increased as GW or MA decreased; for the neighboring normal tissue, opposite trend to that of IM was observed. This study has provided a clear understanding on the impact of the residual motion and proved that if breathing is reproducible gRT is secure despite discontinuous delivery and target motion. The procedures and computational model can be used for commissioning, routine quality assurance, and patient-specific validation of gRT. More work needs to be done for patient-specific dose reconstruction on CT images.

A study of Brachytherapy for Intraocular Tumor (안구내 악성종양에 대한 저준위 방사선요법에 관한 연구)

  • Ji, Gwang-Su;Yu, Dae-Heon;Lee, Seong-Gu;Kim, Jae-Hyu;Ji, Yeong-Hun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • I. Project Title A Study of Brachytherapy for intraocular tumor II. Objective and Importance of the project The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. III. Scope and Contents of the project In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models IV. Results and Proposal for Applications The result were as followed. 1. Eye model was determined as a 25mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15mm, 17mm and 20mm in diameter, and 1.5mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ${\pm}10\%$ and distance deviations are within 0.4mm Maximum error is $-11.3\%$ and 0.8mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192 seeds.

  • PDF

Prediction of Late Rectal Complication Following High-dose-rate Intracavitary Brachytherapy in Cancer of the Uterine Cervix (자궁경부암 환자의 고선량률 강내치료 시행 시 직장합병증의 예측)

  • Lee, Jeung-Eun;Huh, Seung-Jae;Park, Won;Lim, Do-Hoon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.276-282
    • /
    • 2003
  • Purpose: Although high-dose-rate intracavitary radiotherapy (HDR ICR) has been used in the treatment of cervical cancer, the potential for increased risk of late complication, most commonly in the rectum, is a major concern. We have previously reported on 136 patients treated with HDR brachytherapy between 1995 and 1999. The purpose of this study is to upgrade the previous data and confirm the correlation between late rectal complication and rectal dose in cervix cancer patients treated with HDR ICR. Materials and Methods: A retrospective analysis was peformed for 222 patients with cevix cancer who were treated for curative intent with external beam radiotherapy (EBRT) and HDR ICR from July 1995 to December 2001. The median dose of EBRT was 50.4 (30.6$\~$56.4) Gy with a daily fraction size 1.8 Gy. A total of six fractions of HDR ICR were given twice weekly with fraction size of 4 (3$\~$5.5) Gy to A point by Iridium-192 source. The rectal dose was calculated at the rectal reference point using the barium contrast criteria. in vivo measurement of the rectal dose was peformed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 39 months, ranging from 6 to 90 months. Results: Twenty-one patients (9.5$\%$) experienced late rectal bleeding, from 3 to 44 months (median, 13 months) after the completion of RT. The calculated rectal doses were not different between the patients with rectal bleeding and those without, but the measured rectal doses were higher in the complicated patients. The differences of the measured ICR rectal fractional dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose was beyond 16 Gy, when the ratio of the measured rectal dose to A point dose was beyond 70$\%$, or when the measured rectal BED was over 110 Gy$_{3}$, a high possibility of late rectal complication was found. Conclusion: Late rectal complication was closely correlated with measured rectal dose by in vivo dosimetry using TLD during HDR ICR. If data from in vivo dosimetry shows any possibility of rectal bleeding, efforts should be made to reduce the rectal dose.

IGRINS Design and Performance Report

  • Park, Chan;Jaffe, Daniel T.;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Yu, Young Sam;Kaplan, Kyle;Mace, Gregory;Kim, Hwihyun;Lee, Jae-Joon;Hwang, Narae;Kang, Wonseok;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.90-90
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is the first astronomical spectrograph that uses a silicon immersion grating as its dispersive element. IGRINS fully covers the H and K band atmospheric transmission windows in a single exposure. It is a compact high-resolution cross-dispersion spectrometer whose resolving power R is 40,000. An individual volume phase holographic grating serves as a secondary dispersing element for each of the H and K spectrograph arms. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{{\prime}{\prime}}{\times}15^{{\prime}{\prime}}$. IGRINS has a plate scale of 0.27" pixel-1 on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with a SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized ($0.96m{\times}0.6m{\times}0.38m$) rectangular Dewar. The fabrication and assembly of the optical and mechanical components were completed in 2013. From January to July of this year, we completed the system optical alignment and carried out commissioning observations on three runs to improve the efficiency of the instrument software and hardware. We describe the major design characteristics of the instrument including the system requirements and the technical strategy to meet them. We also present the instrumental performance test results derived from the commissioning runs at the McDonald Observatory.

  • PDF

Results of Radiotherapy for the Uterine Cervical Cancer (자궁경부암의 방사선치료성적)

  • Kim, Chul-Yong;Choi, Myung-Sun;Suh, Won-Hyuck
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.63-73
    • /
    • 1988
  • One hundred fifty-four patients with the carcinoma of the uterine cervix were studied retrospectively to assess the result and impact of treatment at Department of Radiation Oncology, Korea University, Hae-Wha Hospital from Feb 1981 through Dec. 1986. Prior to radiotherapy, the patients were evaluated and staged by recommendation of FIGO including physical examination, pelvic examination, cystoscopy, rectosigmoidoscopy, chest X-ray, IVP. Ba enema. Also, an additional pelvic CT scan was obtained for some of the patients. The patients were treated by radiotherapy alone or adjuvant postoperative irradiation; in case of radiation therapy only, whole pelvic irradiation was given with Co-60 teletherapy unit via AP and PA parallel opposing fields or 4-oblique fields, 180 cGy per day, 5 days per week and intracavitary insertion was performed. In satges Ia, Ib, and IIa with small primary lesion, external irradiation was initially given to pelvis up to $2,000\~3,000\;cGy/2frac{1}{2}\;-3frac{1}{2}$ weeks and then intracavitary insertion was performed using Fletcher-Mini-Declos Applicator with cesium-137 cources and followed by external irradiation of $1,000\~2,000\;cGy/1frac{1}{2}\;-2frac{1}{2}$weeks via AP and PA parallel opposing fields with midline shield to spare of bladder and rectum. However, if the primary lesion is large, external irradiation was given without midline shield. More than stages IIb, the patients were treated by external beam irradiation up to 5,400cGy/30f for 6 weeks via 4-oblique portals and at the dose of 5,040cGy/28f the field was cut 5cm from the top margin for spare of small bowel, and followed by intracavitary irradiation, If there was residual tumor an additional dose of $900\~l,200cGy/5\~7f$ was given to parametrium and/or residual tumor area. Total dose of radiation to A and B-point were as follows; A-point; In early stages, Ia, Ib, IIa; $8,000\~9,000$ B-point $5,000\~6,000 cGy$ A-point; In advanced stages IIb, IIIa, IIIb; $9,000\~10,000$ B-point $60,000\~7,000cGy$ The results were obtained and as fellows; 1 The patients distribution according to FIGO staging system were stage Ia 6, Ib 27, IIa 28, IIb 54, IIIa 12, IIIb 18, and stage IVa 9. 2. Value of CT scan were demonstration of cervix tumor mass, parametrial and pelvic side wall tumor spread, pelvic and inguinal lymph nodes metastases, and hydronephrosis. Three dimensional quantitative demonstration of tumor volume is also important in planning radiation therapy. Another advantage of CT scan was detection of recurrent tumor after radiation or surgery. 3. Local control rate of tumor according to the size was $91.3\%$ for less than 5cm in size and $44.6\%$ in tumor over 5cm (p<0.0068). 4. Thirty out of 50 recurrent sites has locoregional failures and 17 cases has distant metastases. And the para-aortic lymph nodes were the most common site for distant metastases. 5. The most common complication was temporal rectal bleeding which was controlled most by conservative management. However, 4 patients required for endoscopic cauterization. 6. The 5-year survival rates showed; stage la and Ib $95\%,\;stage\;IIa\;81\%\;stage\;lIb\;67\%,\;stage\;IIIa\;37.7\%,\;stage\;IIIb\;23\%$ and 3-year survival rate of stage IVa showed $11.6%$, retrospectively.

  • PDF