• Title/Summary/Keyword: Beam Profile

Search Result 471, Processing Time 0.027 seconds

Generation of non-diffraction beam with annular laser output beam (원고리형 레이저광에 의한 근사 무회절 광의 발진)

  • 김현태;박대윤;김기식
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.496-502
    • /
    • 2001
  • We generated a nondiffracting beam and investigated its intensity profile on propagation. We first obtained an annular output beam from Nd:YAG laser with a negative branch unstable ring resonator and, using a 1m focal length lens, we generated a Bessel- Gauss beam. The inner radius of the annular output beam was 2.57 mm and the ring width was 0.145 mm. The intensity profile of the nondiffracting beam did not show any appreciable diffraction up to 33 m distance from the focal lens. This result was compared with the theory.

  • PDF

The Development of a beam profile monitoring system for improving the beam output characteristics (빔 출력 특성 개선을 위한 빔 프로파일 모니터링 시스템 개발)

  • An, Young-jun;Hur, Min-goo;Yang, Seung-dae;Shin, Dae-seob;Lee, Dong-hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2689-2696
    • /
    • 2015
  • Radioactive isotopes which are manufactured using a cyclotron in a radioisotope used for radiation diagnosis is affected by the production yield according to size and shape of the beam and beam uniform degree from irradiated location when the proton beam investigated the target by cyclotron. Therefore, in this paper developed the BPM(Beam Profile Monitor) device capable of measuring the beam cross-section at the cyclotron beam line. It was configured so as to be able to remote control the BPM device in LabView and used the BPM program it was to be able to easily monitor and display to analyze the graph of two-dimensional graph and a three-dimensional beam distribution numerical information of the beam obtained while scanning the tungsten wire to the X and Y axis. The time it takes to measure the beam can be confirmed 37seconds when step motor driving speed was 2000pps. Through a beam readjusted based on the measured beam distribution information by optimizing the beam distribution it can be made to maximize the RI production yield and contribute supply stabilization.

Development of Degenerated Beam Elements Using Higher-Order Displacement Profile (고차(高次) 변위(變位)를 고려(考慮)한 요소(要素)의 해석(解析))

  • Shin, Young Shik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.3
    • /
    • pp.75-86
    • /
    • 1982
  • The degeneration of two classes of thick beam elements has been conducted, one (DB6) based on the conventional Timoshenko beam assumptions whereas the other (DB7) based on the assumed cubic axial displacement profile. While an adjustable shear correction factor is required for the DB 6 element to compensate for the unrealistic distribution of shear strain across the thickness, the DB 7 element assumes the more realistic quadratic profile of shear strain at the outset. With the plane-stress continuum solution as reference, solutions obtained by these two element models are compared with the analytical Timoshenko solution, the analytical thin beam solution and several available solutions of other existing beam elements. The result indicates that the performance of the higher order beam element DB 7 is consistently superior to any others. This is true for the whole range of aspect ratios of beam, in both static and free vibration analyses.

  • PDF

Analysis of Dose Distribution According to the Initial Electron Beam of the Linear Accelerator: A Monte Carlo Study

  • Park, Hyojun;Choi, Hyun Joon;Kim, Jung-In;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.10-19
    • /
    • 2018
  • Background: Monte Carlo (MC) simulation is the most accurate for calculating radiation dose distribution and determining patient dose. In MC simulations of the therapeutic accelerator, the characteristics of the initial electron must be precisely determined in order to achieve accurate simulations. However, It has been computation-, labor-, and time-intensive to predict the beam characteristics through predominantly empirical approach. The aim of this study was to analyze the relationships between electron beam parameters and dose distribution, with the goal of simplifying the MC commissioning process. Materials and Methods: The Varian Clinac 2300 IX machine was modeled with the Geant4 MC-toolkit. The percent depth dose (PDD) and lateral beam profiles were assessed according to initial electron beam parameters of mean energy, radial intensity distribution, and energy distribution. Results and Discussion: The PDD values increased on average by 4.36% when the mean energy increased from 5.6 MeV to 6.4 MeV. The PDD was also increased by 2.77% when the energy spread increased from 0 MeV to 1.019 MeV. In the lateral dose profile, increasing the beam radial width from 0 mm to 4 mm at the full width at half maximum resulted in a dose decrease of 8.42% on the average. The profile also decreased by 4.81% when the mean energy was increased from 5.6 MeV to 6.4 MeV. Of all tested parameters, electron mean energy had the greatest influence on dose distribution. The PDD and profile were calculated using parameters optimized and compared with the golden beam data. The maximum dose difference was assessed as less than 2%. Conclusion: The relationship between the initial electron and treatment beam quality investigated in this study can be used in Monte Carlo commissioning of medical linear accelerator model.

Microwave Electric Field and Magnetic Field Simulations of an ECR Plasma Source for Hyperthermal Neutral Beam Generation

  • Lee, Hui-Jae;Kim, Seong-Bong;Yu, Seok-Jae;Jo, Mu-Hyeon;NamGung, Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.501-501
    • /
    • 2012
  • A 2.45 GHz electron cyclotron resonance (ECR) plasma source with a belt magnet assembly configuration (BMC) was developed for hyperthermal neutral beam (HNB) generation. A plasma source for high flux HNB generation should be satisfied with the requirements: low pressure operation, high density, and thin plasma. The ECR plasma source with BMC achieved high density at low operation pressure due to electron confinement enhancement caused by high mirror ratio and drifts in toroidal direction. The 2.45 GHz microwave launcher had a circularly bended WR340 waveguide with slits. The microwave E-field profile induced by the microwave launcher was studied in this paper. The E-field profile was a cups field perpendicular to B-filed at ECR zone. The optimized E-field profile and B-field were found for effective ECR heating.

  • PDF

Static behavior of novel RCS through-column-type joint: Experimental and numerical study

  • Nguyen, Xuan Huy;Le, Dang Dung;Nguyen, Quang-Huy
    • Steel and Composite Structures
    • /
    • v.32 no.1
    • /
    • pp.111-126
    • /
    • 2019
  • This paper deals with experimental investigation and modeling of the static behavior of a novel RCS beam-column exterior joint. The studied joint detail is a through-column type in which an H steel profile totally embedded inside RC column is directly welded to the steel beam. The H steel profile was covered by two supplementary plates in the joint area in order to avoid the stirrups resisting shear in the joint area. Two full-scale through-column-type RCS joints were tested under static loading. The objectives of the tests were to examine the connection performance and to highlight the contribution of two supplementary plates on the shear resistance of the joint. A reliable nonlinear 3D finite element model was developed using ABAQUS software to predict the response and behavior of the studied RCS joint. An extensive parametric study was performed to investigate the influences of the stirrups, the encased profile length and supplementary plate length on the behavior of the studied RCS joint.

The Simulation of Micro Optical Cross Connect Based On Ball Lens (구형렌즈를 사용한 초소형 광 스위치에서의 Simulation)

  • Lee, Doo-Won;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.594-596
    • /
    • 2000
  • The best simulation condition for the fiber collimator that uses ball lenses was investigated. This kind of fiber collimator can be used in a Micro-Optical-Cross-Connects(MOXC). MOXC is composed of collimating ball lenses, micro mirrors and single-mode fibers. In order to design a MOXC, it is very important to calculate beam path, beam radius, divergence angle that determines the insertion loss of the MOXC. Since the beam profile from the fiber facet is not exact Gaussian profile, it was found that the simulation condition in which beam waist exists on the fiber facet, ignoring Numerical Aperture(NA), gives best agreement with the experimental results. Beam radii were measured with conventional knife edge method.

  • PDF

A study on the structural characteristics and roll behavior of suspension for the section profile of torsion beam (토션빔의 단면형상에 다른 현가계의 구조적 특성과 롤 거동에 관한 연구)

  • 이동찬;변준형
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.195-202
    • /
    • 1999
  • The kinematic and complicance characteristics of torsion beam axle is structurally related to the location and section profile of torsion beam and the span from body mounting point to wheel center. This paper presents the effect of section properties in torsion beam on the structural characteristics and roll behavior of suspension. The structural characteristics is on the maximum stress on the welding area of torsion beam and the roll behavior is on roll steer and roll-camber of suspension which are important for controllability and stability in cornering. Four factors are used for the section design of torsion beam, which are thickness , midline length, are inner radius, and sector half angle . Through the structural and quasi-static analysis made for six torsion beam axle models, it can be noticed that roll steer and the structural durability of suspension are closely related to warping constant and shear center in section properties of torsion beam.

  • PDF

Buried Channel PMOS에서 이온 주입된 $BF_2$ 열처리 거동

  • Heo, Tae-Hun;No, Jae-Sang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.374-374
    • /
    • 2012
  • 반도체 소자의 크기가 100 nm 이하로 감소되면 통상적인 이온 주입 조건인 이온 에너지, 조사량 및 이온 주입 각도뿐만 아니라 Dose Rate 및 모재 온도가 Dopant Profile을 조절하는 데에 있어서 매우 중요한 인자로 작용한다. 본 연구에서는 Ribbon-beam 및 Spot-beam을 사용하여 활성화 열처리 후 Dopant Profile을 분석하였다. 이온 주입은 모든 시편에서 $BF_2$를 가속 에너지 10 keV 및 조사량 $2{\times}10^{15}/cm^2$로 고정하였다. 이온 주입 후 도펀트 활성화는 100% 질소 분위기 하에서 $850^{\circ}C$-30s 조건으로 RTA 열처리를 수행하였다. Boron 및 Fluorine의 Profile은 SIMS 분석을 통하여 구하였다. Spot-beam은 Ribbon-Beam에 비하여 Dose Rate 및 Cooling Efficiency가 높기 때문에 이온 주입 후 더욱 많은 양의 Primary-defect를 발생시키고 이에 따라 두꺼운 비정질 충을 형성한다. $BF_2$ 이온 주입 된 시편에서 B 및 F의 농도 Peak-height는 a/c 계면에 위치하는 것을 관찰하였다. 또한 B 및 F의 농도 Peak-height는 Silicon 모재의 온도가 증가할수록 증가하는 것을 관찰하였다. Silicon 모재의 온도가 증가함에 따라 Active-area의 면저항이 변화하지 않는 상태에서 Vt (Threshold Voltage)가 급격히 감소함을 관찰 하였다. 비정칠 층의 두께가 증가할수록 a/c 계면 하단에 잔존하는 Residual-defect의 양이 감소하고 이는 측면확산을 감소시키는 역할을 한다는 것이 관찰되었다.

  • PDF