• 제목/요약/키워드: Beam Deviation

검색결과 222건 처리시간 0.025초

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

An anatomical study on the mandibular medial surface by CBCT analysis for safer implant placement (안전한 임플란트 식립을 위한 하악골 내측면의 CBCT를 이용한 해부학적 연구)

  • Lee, Jung-Kyo;Kim, Yeo-Gab
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권1호
    • /
    • pp.43-48
    • /
    • 2011
  • Introduction: This study examined the anatomical morphology of the medial surface of the posterior mandible using 3-dimensional cone-beam computed tomography (CT) images to reduce the number of complications related to dental implant placement. Materials and Methods: Fifty patients were enrolled in this study with an average age (${\pm}$standard deviation) of 44.28 (${\pm}13.05$). On the coronal views cone-beam CT of the first molars, the distance between the top of the canal and alveolar crest vertical distance (VD), the distance between the upper-most point of the canal and the point perpendicular to the lingual cortical margin of the mandible lingual distance (LD), the location of the starting point of VD for reducing from the vertical reference line (VD point), and the inclination of the mandibular medial surface (lingual inclination) were measured, and a statistical evaluation was performed using SPSS for Windows version 15.0. Results: The mean VD0 was $16.91{\pm}2.47\;mm$ and VDx decreased with increasing x value. The mean LD was $5.27{\pm}1.36\;mm$. The VD began to decrease at the mean location of $6.12{\pm}0.96\;mm$ from the vertical reference line. The mean lingual inclination was $1.52{\pm}0.72^{\circ}$. Conclusion: These results will assist in the accurate placement of dental implants and the reduction of complications, particularly in the case of preoperative implant planning using only 2-dimensional imaging methods. (ex. panoramic radiography)

Assessment of anterior-posterior jaw relationships in Korean adults using the nasion true vertical plane in cone-beam computed tomography images

  • Park, Youngju;Cho, Youngserk;Mah, James;Ahn, Janghoon
    • The korean journal of orthodontics
    • /
    • 제46권3호
    • /
    • pp.163-170
    • /
    • 2016
  • Objective: The aims of this study were to investigate a simple method for assessing anterior-posterior jaw relationships via cone-beam computed tomography (CBCT) images taken in the natural head position (NHP) relative to the nasion true vertical plane (NTVP), and measure normative data in Korean adults with normal profiles. Methods: Subjects were selected from patients presenting for third molar extraction and evaluated as having normal profiles by three examiners. The CBCT images of 80 subjects (39 males, 41 females) were taken in the NHP according to Solow and Tallgren's method. Linear measurements of the A-point, B-point, and Pog were calculated relative to the NTVP. Student's t -test was used to assess sexual differences in these measurements. Results: The mean linear measurements of the A-point, B-point, and Pog relative to the NTVP were 0.18 mm (standard deviation [SD], 4.77 mm), -4.00 mm (SD, 6.62 mm), and -2.49 mm (SD, 7.14 mm) respectively in Korean males, and 1.48 mm (SD, 4.21 mm), -4.07 mm (SD, 6.70 mm) and -2.91 mm (SD, 7.25 mm) in Korean females respectively. There were no statistically significant differences between Korean males and females (p < 0.05). Conclusions: Three-dimensional CBCT analysis using the NTVP is a simple and reliable method for assessing anterior-posterior skeletal relationships.

Three-dimensional observations of the incisive foramen on cone-beam computed tomography image analysis

  • Kim, Yeon-Tae;Lee, Jae-Hong;Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • 제50권1호
    • /
    • pp.48-55
    • /
    • 2020
  • Purpose: The purpose of this study was to utilize cone-beam computed tomography (CBCT) image analysis to obtain anatomical information related to the morphology of the incisive foramen to provide useful data regarding implant placement and clinical procedures such as anesthesia. Methods: The study included 167 patients who underwent CBCT scans over 20 years. Three components were measured: 1) the anteroposterior and mediolateral diameter of the incisive foramen, 2) the horizontal bone thickness anterior to the incisive foramen, and 3) the vertical bone height coronal to the incisive foramen. All measurements were expressed as mean±standard deviation and were analyzed by a single examiner. Results: The anteroposterior diameter of the incisive foramen was wider than the mediolateral diameter (P<0.001). The diameter of the incisive foramen in patients in whom the central incisors were present was smaller than that in those in whom at least one central incisor was absent, but no statistically significant difference between the groups was observed. The horizontal bone thickness in the patients with central incisors was statistically significantly larger than that in the patients without at least one central incisor (P<0.001). The same pattern was observed with regard to vertical height, but that difference was not statistically significant. Conclusions: The buccal bone thickness anterior to the incisive foramen was significantly decreased after central incisor loss. It is necessary to identify the morphology of the bone and the location of the incisive foramen via CBCT to avoid invasion of the incisive foramen and nasopalatine canal.

Development of Ultrasonic Multi-Beam Sludge Meter For Effluent Facilities Automation (정수장에서 배출수 공정 자동화를 위한 초음파 다중빔 슬러지 농도계 개발)

  • Jang, Sang-Bok;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제18권9호
    • /
    • pp.2313-2321
    • /
    • 2014
  • A concentration meter is widely used at purification plants, sewage treatment plants and waste water treatment plants to sort and transfer high concentration sludge and to control the amount of chemical input. This study has been prepared for improving efficiency of operation on sludge processes and to establish a basic for factory automation by accuracy improvement and problem solution of sludge concentration meter. The concentration meter's accuracy and stability is improved by applying multi-beam sensors and minimum deviation linear average filtering. Furthermore maintenance without cut-off of water in sludge operation is possible by detachable sensors. The performance of multi-beam concentration meter has been variously verified by the pilot plant experiment.

The Impact Properties and Wear Resistance of Polybutylene terephthalate (PBT) Cross-linked by Electron Beam Irradiation (전자선 가교된 PBT의 충격 특성 및 내마모 특성 연구)

  • Shin, Bum Sik;Ko, Keum Jin;Jeun, Joon Pyo;Kim, Hyun Bin;Oh, Seung Hwan;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • 제5권2호
    • /
    • pp.145-149
    • /
    • 2011
  • Poly(butylenes terephthalate) have made large strides in applications of injection, extrusion, and molding material due to their excellent thermal resistance and appropriate mechanical properties. However, PBT was not hard polymer but a soft polymer which caused low absorption of external energy and the defect of being easily broken with the strong impact. Thus, the electron beam irradiation was carried out over a range of irradiation doses from 100 to 1,000 kGy for enhancing the properties. The decreases of $T_m$, $T_c$, and enthalpy were observed as increasing the absorbed dose in the results of DSC analysis. The improvement in the impact strength of PBT was clearly observed as the absorbed dose was increased. This was probably due to the 3-dimensional network structures, resulting in increasing the absorption of impact energy. In addition, the wear properties had increased at higher than 300 kGy. The negative deviation of weight loss confirmed the improvement of the wear properties of PBT, as evidenced by SEM observation on the wear surfaces.

The Comparative Analysis of Numerical and Experimental Results for Prediction of Workpiece Temperature in the Commercial Reheating Furnace (상용급 재가열로에서 소재 온도 예측을 위한 해석과 실험 결과의 비교 분석)

  • Lee, Chunsik;Lee, Jae Yong;Ryu, BoHyun;Rhim, DongRyul
    • Journal of the Korean Institute of Gas
    • /
    • 제23권4호
    • /
    • pp.74-79
    • /
    • 2019
  • Specially designed test material was used for workpiece temperature measurement in the commercial reheating furnace and a linearized thermal model was applied for real time temperature prediction. The applied furnace is a walking beam type and specification of the workpiece is a STS302 which is 160mm in width, 160mm in height and 8100mm in length. Also six thermocouples were installed in width, height and length direction for temperature measurement. Ambient temperature in the furnace was raised to 1265 Celsius degrees and it took about 2.5 hours from loading to discharging of the workpiece. As a result of the experiment, temperature of the workpiece at discharge was 1257 Celsius degrees on the average in the range of 1256 to 1259 Celsius degrees, and predicted average temperature through the thermal model was 1251 Celsius degrees. Therefore, the deviation of the analysis and test results is about 6 degrees, which is within the range of 10 degrees required by the industry.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • 제53권1호
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Effects of the cone-beam computed tomography protocol on the accuracy and image quality of root surface area measurements: An in vitro study

  • Chanikarn Intarasuksanti;Sangsom Prapayasatok;Natnicha Kampan;Supassara Sirabanchongkran;Pasuk Mahakkanukrauh;Thanapat Sastraruji;Pathawee Khongkhunthian;Kachaphol Kuharattanachai;Kanich Tripuwabhrut
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.325-333
    • /
    • 2023
  • Purpose: The objective of this study was to evaluate and compare the accuracy and image quality of root surface area (RSA) measurements obtained with various cone-beam computed tomography (CBCT) protocols, relative to the gold standard of micro-computed tomography (CT), in an in vitro setting. Materials and Methods: Four dry human skulls were scanned using 8 different protocols, with voxel sizes of 0.15 mm, 0.3 mm, and 0.4 mm. Three-dimensional models of the selected teeth were constructed using CBCT and microCT protocols, and the RSA was automatically measured by the image-processing software. The absolute difference in the percentage of the RSA(%ΔRSA) was calculated and compared across the 8 CBCT protocols using repeatedmeasures analysis of variance. Finally, image quality scores of the RSA measurements were computed and reported in terms of percent distribution. Results: No significant differences were observed in the %ΔRSA across the 8 protocols (P>0.05). The deviation in %ΔRSA ranged from 1.51% to 4.30%, with an increase corresponding to voxel size. As the voxel size increased, the image quality deteriorated. This decline in quality was particularly noticeable at the apical level of the root, where the distribution of poorer scores was most concentrated. Conclusion: Relative to CBCT protocols with voxel sizes of 0.15mm and 0.3mm, the protocols with a voxel size of 0.4 mm demonstrated inferior image quality at the apical levels. In spite of this, no significant discrepancies were observed in RSA measurements across the different CBCT protocols.

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • 제17권3호
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF