The Comparative Analysis of Numerical and Experimental Results for Prediction of Workpiece Temperature in the Commercial Reheating Furnace  

Lee, Chunsik (Plant Engineering Center, Institute for Advanced Engineering)
Lee, Jae Yong (Plant Engineering Center, Institute for Advanced Engineering)
Ryu, BoHyun (Plant Engineering Center, Institute for Advanced Engineering)
Rhim, DongRyul (Plant Engineering Center, Institute for Advanced Engineering)
Publication Information
Journal of the Korean Institute of Gas / v.23, no.4, 2019 , pp. 74-79 More about this Journal
Abstract
Specially designed test material was used for workpiece temperature measurement in the commercial reheating furnace and a linearized thermal model was applied for real time temperature prediction. The applied furnace is a walking beam type and specification of the workpiece is a STS302 which is 160mm in width, 160mm in height and 8100mm in length. Also six thermocouples were installed in width, height and length direction for temperature measurement. Ambient temperature in the furnace was raised to 1265 Celsius degrees and it took about 2.5 hours from loading to discharging of the workpiece. As a result of the experiment, temperature of the workpiece at discharge was 1257 Celsius degrees on the average in the range of 1256 to 1259 Celsius degrees, and predicted average temperature through the thermal model was 1251 Celsius degrees. Therefore, the deviation of the analysis and test results is about 6 degrees, which is within the range of 10 degrees required by the industry.
Keywords
Reheating Furnace; Workpiece Temperature; Walking Beam; Experiment;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Radhakrishnan Purushothaman, "Evaluation and Improvement of Heat Treat Furnace Model", Ph.D Dissertation, Worcester Polytechnic Institute, (2008)
2 Lee Chunsik et al., "Experimental Study of Workpiece Temperature Variation in Reheating Furnace", Journal of Energy Engineering, 26(4), 100-106, (2017)   DOI
3 Jiraphon Srisertpol et al., "Estimation of the Mathematical Model of the Reheating Furnace Walking Hearth Type in Heating Curve Up Process", International Journal of Mathematical Models and Methods in Applied Sciences, 5(1), 167-174, (2011)
4 Pongam T. et al., "Manufacturing Process Identification for the Reheating Furnace Walking Hearth Type Using Genetic Algorithm", International Journal of Modeling and Optimization, 2(2), 114-118, (2012)
5 Kim K. M. et al., " A numerical study on the efficiency of an industrial furnace for oxygen combustion conditioins", Journal of Energy Engineering, 24(3), 82-88, (2015)   DOI