• 제목/요약/키워드: Beam Center

검색결과 2,020건 처리시간 0.031초

ION BEAM APPLICATION

  • Baba Mamoru
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.319-326
    • /
    • 2006
  • A brief review is presented on the ion beam application in science and technology. ion beams are used very effectively in various fields of science and technology, on the basis of advance in accelerator technology and experimental techniques for ion beam utilization. Recent progress in this field is reviewed in terms of the direct ion beam utilization like ion beam analysis, and the utilization of neutrons as secondary particles.

핫스탬핑에 의한 자동차 도어 임팩트빔의 개발 (Construction of Vehicle Door Impact Beam Using Hot Stamping Technology)

  • 이현우;황정복;김선웅;김원혁;유승조;임현우;염영진
    • 대한기계학회논문집A
    • /
    • 제34권6호
    • /
    • pp.797-803
    • /
    • 2010
  • 자동차의 측면 충돌시 승객을 보호하고자 박판재를 이용하여 자동차의 도어 임팩트빔을 핫스탬핑공법을 이용하여 개발하였다. 핫스탬핑 기술은 차량의 차체 강성을 증가시킬 뿐만 아니라 차체 중량 및 부품 수 축소로 인한 공정의 감소도 가능하게 한다. 핫스탬핑 시편을 제작하고, 기계적 물성시험을 수행하여 물성 데이터를 확보하였다. 핫스탬핑 임팩트빔의 성형해석및 구조해석을 이용한 최적 설계를 수행하여 기존 파이프형태의 임팩트빔보다 강도는 102% 향상되고, 중량은 34% 감소된 핫스탬핑 임팩트빔을 개발하였다.

Study of ion beam shaping of an anode-type ion source coupled with a Whenelt mask

  • Huh, Yunsung;Hwang, Yunseok;Kim, Jeha
    • Applied Science and Convergence Technology
    • /
    • 제27권4호
    • /
    • pp.70-74
    • /
    • 2018
  • We fabricated an anode-type ion source driven by a charge repulsion mechanism and investigated its beam shape controlled by a Whenelt mask integrated at the front face of the source. The ion beam shape was observed to vary by changing the geometry of the Whenelt mask. As the angle of inclination of the Whenelt mask was varied from $40^{\circ}$ to $60^{\circ}$, the etched area at a thin film was reduced from 20 mm to 7.5 mm at the working distance of 286 mm, and the light transmittance through the etched surface was increased from 78% to 80%, respectively. In addition, for the step height difference, ${\Delta}$ between the inner mask and the outer mask of ${\Delta}=0$, -1 mm, and +1 mm, we observed the ion beam shape was formed to be collimated, diverged, and focused, respectively. The focal length of the focused beam was 269 mm. We approved experimentally a simple way of controlling the electric field of the ion beam by changing the geometry of the Whenelt mask such that the initial direction of the ion beam in the plasma region was manipulated effectively.

Progress on Proton Therapy Facility Project in National Cancer Center, Korea

  • Kim, Jong-Won;Park, Sung-Yong;Park, Dahl;Kim, Dae-Yong;Shin, Kyung-Hwan;Cho, Kwan-Ho
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.180-182
    • /
    • 2002
  • A Proton Therapy Center was established this year in National Cancer Center, Korea. We chose IBA of Belgium as the vendor of the equipment package. A 230 MeV fixed-energy cyclotron will deliver proton beams into two gantry rooms, one horizontal beam room, and one experimental station. The building for the equipment is currently under design with a special emphasis on radiation shielding. Installation of equipments is expected to begin in September next year starting with the first gantry, and the acceptance test will be performed about a year later. To generate therapeutic radiation fields the wobbling method will be a main treatment mode for the first gantry. A pencil beam scanning system on the other hand will be equipped for the second gantry relying on the availability at the time of installation. The beam scanning with intensity modulation adapted will be a most advanced form in radiation therapy known as IMPT. Some details on the project progress, scope of the system, and design of building are described.

  • PDF

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo;Han, Youngyih;Kim, Jinsung;Ahn, Sung Hwan;Ju, Sang Gyu;Jung, Sang Hoon;Chung, Yoonsun;Cho, Sungkoo;Jo, Kwanghyun;Shin, Eun Hyuk;Hong, Chae-Seon;Shin, Jung Suk;Park, Seyjoon;Kim, Dae-Hyun;Kim, Hye Young;Lee, Boram;Shibagaki, Gantaro;Nonaka, Hideki;Sasai, Kenzo;Koyabu, Yukio;Choi, Changhoon;Huh, Seung Jae;Ahn, Yong Chan;Pyo, Hong Ryull;Lim, Do Hoon;Park, Hee Chul;Park, Won;Oh, Dong Ryul;Noh, Jae Myung;Yu, Jeong Il;Song, Sanghyuk;Lee, Ji Eun;Lee, Bomi;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • 제33권4호
    • /
    • pp.337-343
    • /
    • 2015
  • Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.

THE NEW TYPE BROAD BEAM ION SOURCES AND APPLICATIONS

  • You, D.W.;Feng, Y.C.;Wang, Y.;Kuang, Y.Z.
    • 한국진공학회지
    • /
    • 제4권S2호
    • /
    • pp.131-138
    • /
    • 1995
  • The broad beam ion sources of hot filament plasma type have widely used for modifications of materials and thin films, and the new type intensive current broad beam metal ion source including reactive gaseous ion beams is needed for preparing the hard coating films such as DLC, $\beta-C_3N_4$ Carbides, Nitrides, Borides etc. Now a electorn beam evaporation(EBE) broad beam metal ion source has been developed for this purpose in our lab. CN film has been formed by the EBE ion source. Study of the CN film shows that it has high hardness(HK=5800kgf/$\textrm {mm}^2$)and good adhesion. This method can widely changes the ratio of C/N atom's concentrations from 0.14 to 0.6 and has high coating rate. The low energy pocket ion source which was specially designed for surface texturing of medical silicon rubber was also developed. It has high efficiency and large uniform working zone. Both nature texturing and mesh masked texturing of silicon rubbers were performed. The biocompatibility was tested by culture of monocytes, and the results showed improved biocompatibility for the treated silicon rubbers. In addition, the TiB2 film synthesized by IBED is being studied recently in our lab. In this paper, the results which include the hardness, thickness of the films and the AES, XRD analysis as well as the tests of the oxidation of high temperature and erosion will be presented.

  • PDF

Measurement of Plasma Parameters (Te and Ne) and Reactive Oxygen Species in Nonthermal Bioplasma Operating at Atmospheric Pressure

  • Choi, Eun Ha;Kim, Yong Hee;Kwon, Gi Chung;Choi, Jin Joo;Cho, Guang Sup;Uhm, Han Sup;Kim, Doyoung;Han, Yong Gyu;Suanpoot, Pradoong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.141-141
    • /
    • 2013
  • We have generated the needle-typed nonthermal plasma jet by using an Ar gas flow at atmospheric pressure. Diagnostics of electron temperature anddensity is critical factors in optimization of the atmospheric plasma jet source in accordance with the gas flow rate. We have investigated the electron temperature and density of plasma jet by selecting the four metastable Ar emission lines based on the atmospheric collisional radiative model and radial profile characteristics of current density, respectively. The averaged electron temperature and electron density for this plasma jet are found to be ~1.6 eV and ~$3.2{\times}10^{12}cm^{-3}$, respectively, in this experiment. The densities of OH radical species inside the various bio-solutions are found to be higher by about 4~9 times than those on the surface when the argon bioplasma jet has been bombarded onto the bio-solution surface. The densities of the OH radicalspecies inside the DI water, DMEM, and PBS are measured to be about $4.3{\times}10^{16}cm^{-3}$, $2.2{\times}10^{16}cm^{-3}$, and $2.1{\times}10^{16}cm^{-3}$, respectively, at 2 mm downstream from the surface under optimized Ar gas flow 250 sccm.

  • PDF

수술현미경에서의 다중형광영상을 이용한 뇌종양과 혈관영상 검출 시스템 연구 (Study of a Brain Tumor and Blood Vessel Detection System Using Multiple Fluorescence Imaging by a Surgical Microscope)

  • 이현민;김홍래;윤웅배;김영재;김광기;김석기;유헌;이승훈;신민선;권기철
    • 한국광학회지
    • /
    • 제26권1호
    • /
    • pp.23-29
    • /
    • 2015
  • 본 연구에서는 뇌 종양 수술에서 다수의 광원과 빔 스플리터 모듈을 사용해 종양과 혈관의 형광영상을 동시에 검출하고 획득한 형광영상을 동일한 디스플레이 장치에 표시함으로써 시술자에게 종양과 혈관의 정확한 정보를 실시간으로 제공할 수 있는 현미경 시스템을 제안한다. 5-ALA(5-Aminolevulinic acid) 와 ICG(Indocyanine green) 의 형광영상의 동시 검출을 위해 빔 스플리터(beam-splitter : BS)모듈을 사용하였고 5-ALA는 600nm, ICG는 800nm이상의 파장 대역에서 가장 효율이 뛰어나도록 구성하였다. 빔 스플리터 모듈은 파장 대역에 따라 광학기기의 구조를 변경할 수 있고 필터를 탈, 착 가능한 구조로 설계하여 필요에 따라 빔 스플리터와 필터의 종류를 변경할 수 있으며 5-ALA 및 ICG 이외의 형광염료를 사용한 시술에서 사용할 수 있다. 빔 스플리터 모듈을 통한 형광영상은 5-ALA는 가시광역, ICG는 근적외선 영역을 검출 할 수 있는 CCD 카메라를 장착해 동일한 디스플레이에서 확인할 수 있고 획득한 형광영상은 닮음 변환(similarity transform)을 이용해 원영상과 정합하여 실시간으로 시술자에게 제공하는 시스템을 구현하였다.

모노레일 시스템 궤도빔의 합리적인 경간장 결정방안 (The plan of rational span decision to track beam of monorail)

  • 안용모;백차승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.199-205
    • /
    • 2008
  • The monorail system as new transportation system mostly has being constructed as an elevated construction and the track beam as mostly main work type occupy the important parts. The structure of monorail system, the track beam support directly vehicle's load and comprised of the track beam structure to be traveling side and understructure to be transmitted from their load to the ground. In particular, in case of construction to elevated structure in the center of a city, it is important to decision plan for span to be considered the economic, execution and maintenance according to transport, installation, and the structure problem, scene and civil appeals to be decided the beam elevation and span. Therefore the standard span of monorail track beam shall be considered the efficient execution, economic and transportation. And propose to reasonable decision plan incorporated the minimizing the road occupied width due to openness to center of a city and bridge pole, minimize to basis size.

  • PDF