• Title/Summary/Keyword: Bead size

Search Result 260, Processing Time 0.026 seconds

Analysis of Hydrodynamic Similarity in Three-Phase Fluidized Bed Processes (삼상유동층 공정에서 수력학적 Similarity 해석)

  • Lim, Ho;Lim, Hyun-Oh;Jin, Hae-Ryoung;Lim, Dae-Ho;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.790-797
    • /
    • 2011
  • Hydrodynamic similarity was analyzed by employing scaling factor in three phase fluidized beds. The scaling factor was defined based on the holdups of gas, liquid and solid particles and effectivity volumetric flux of fluids between the two kinds of fluidized beds with different column diameter. The column diameter of one was 0.102 m and that of the other was 0.152 m. Filtered compressed air, tap water and glass bead of which density was 2,500 kg/$m^3$ were used as gas, liquid and solid phases, respectively. The individual phase holdups in three phase fluidized beds were determined by means of static pressure drop method. Effects of gas and liquid velocities and particle size on the scaling factors based on the holdups of each phase and effective volumetric flux of fluids were examined. The deviation of gas holdup between the two kinds of three phase fluidized beds decreased with increasing gas or liquid velocity but increased with increasing fluidized particle size. The deviation of liquid holdup between the two fluidized beds decreased with increasing gas or liquid velocity or size of fluidized solid particles. The deviation of solid holdup between the two fluidized beds increased with increasing gas velocity or particle size, however, decreased with increasing liquid velocity. The deviation of effective volumetric flux of fluids between the two fluidized beds decreased with increasing gas velocity or particle size, but increased with increasing liquid velocity. The scaling factor, which was defined in this study, could be effectively used to analyze the hydrodynamic similarity in three phase fluidized processes.

Stabilization of Lactobacillus with Double Matrix Capsulation (더블매트릭스 캡슐화에 의한 유산균의 안정화)

  • Kim, Dae-Seop;Park, Mi-Ey;Yoo, So-Yeun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.656-663
    • /
    • 2013
  • This study using yogurt of food in order to increase the conservativeness and stability of lactobacillus, to be deliciously flavored and give it visual differential effect, were described regarding making the preparing method of double matrix capsulation in food industries. Our study group was especially made to soft and moisture cream using 5wt% of sucrose ester emulsifier as first capsulation. Double matrix capsulation was formed with the best stabilized bead type capsules when it blended 1:3 ratio of chitosan and alginate. The bead diameter size was about 2.5~4mm (mean diameter: 3mm). Activity of lactobacillus containing cream for depending on various pH variations showed that alkalinity ($pH=10.3{\pm}0.3$) condition was higher than acidity ($pH=4.3{\pm}0.3$) and neutrality ($pH=7.12{\pm}0.2$) conditions. After a month, it also was certified to the activity of lactobacillus in incubated at $37^{\circ}C$ in culture medium. As application of food industry, we developed the containing lactobacillus capsule and 5 colored kinds of double matrix capsulation in yogurt cream. As for above mentioned those results, one of tool to stabilize the living lactobacillus, doubled matrix capsulation greatly be expected to contribute to food industry. Furthermore, it can be expected to apply the drug delivery system (DDS) to active ingredients of stabilizing technologies at drug and cosmetic industries.

Dynamics and die design in continuous and patch slot coating processes (Continuous 와 pattern slot 코팅 공정에서의 유동특성과 다이 설계)

  • Kim Su-Yeon;Shim Seo-Hoon;Shin Dong-Myeong;Lee Joo-Sung;Jung Hyun-Wook;Hyun Jae-Chun
    • Proceedings of the Korean Society of Rheology Conference
    • /
    • 2006.06a
    • /
    • pp.81-84
    • /
    • 2006
  • Slot coating process, in continuous and patch modes, has been applied for the many precise coating products, e.g., flat panel displays and second batteries. However, manufacturing uniform coating products is not a trivial task at high-speed operations because various flow instabilities or defects such as leaking, bubbles, ribbing, and rivulets are frequently observed in this process. It is no wonder, therefore, that many efforts to understand the various aspects of dynamics and coating windows of this process have been made both in academia and industry. In this study, as the first topic, flow dynamics within the coating bead in slot coating process has been investigated using the one-dimensional viscocapillary model by lubrication approximation and two-dimensional model by Flow-3D software. Especially, operability windows in both 1D and 2D cases with various slot die lip designs have been successfully portrayed. Also, effects of process conditions like viscosity and coating gap size on slot coating window have been analyzed. Also, some experiments to find minimum coating thickness and coating windows have been conducted using slot die coater implemented with flow visualization device, corroborating the numerical results. As the second topic, flow dynamics of both Newtonian and Non-Newtonian fluids in patch or pattern slot coating process, which is employed in manufacturing IT products such as secondary batteries, has been investigated for the purpose of optimal process designs. As a matter of fact, the flow control in this system is more difficult than in continuous case because od its transient or time-dependent nature. The internal die and die lip designs for patterned uniform coating products have been obtained by controlling flow behaviors of coating liquids issuing from slot. Numerical simulations have been performed using Fluent and Flow-3D packages. Flow behavior and pressure distribution inside the slot die has been compared with various die internal shapes and geometries. In the coating bead region, efforts to reduce irregular coating defects in head and tail parts of one patterned coating unit have been tried by changing die lip shapes. It has been concluded that optimal die internal design gas been developed, guaranteeing uniform velocity distribution of both Newtonian and shear thinning fluids at the die exit. And also optimal die lip design has been established, providing the longer uniform coating layer thickness within one coating unit.

  • PDF

Distribution of Magnetic Field Depending on the Current in the μ-turn Coil to Capture Red Blood Cells (적혈구 포획용 미크론 크기 코일에 흐르는 전류의 크기에 따른 자기장 분포 특성)

  • Lee, Won-Hyung;Chung, Hyun-Jun;Kim, Nu-Ri;Park, Ji-Soo;Lee, Sang-Suk;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.5
    • /
    • pp.162-168
    • /
    • 2015
  • The ${\mu}$-turn coil having a width of ${\mu}m$ on the GMR-SV (giant magnetoresistance-spin valve) device based on the antiferromagnetic IrMn layer was fabricated by using the optical lithography process. In the case of GMR-SV film and GMR-SV device, the magnetoresistance ratios and the magnetic sensitivities are 4.4%, 2.0%/Oe and 1.6 %, 0.1%/Oe, respectively. In the y-z plane the distribution of magnetic field of GMR-SV device and $10{\mu}$-turns coil which put under the several magnetic bead(MB)s with a diameter of $1{\mu}m$ attached to RBC (red blood cell) was analyzed by the computer simulation using the finite element method. When the AC currents of 20 kHz from 0.1 mA to 10.0 mA flow to the 10 turns ${\mu}$-coil, the magnetic field at the position of $z=0{\mu}m$ at the center of coil was calculated from $30.1{\mu}T$ to $3060{\mu}T$ in proportion to the current. The magnetic field at the position of $z=10{\mu}m$ was decreased to one-sixth of that of $z=0{\mu}m$. It was confirmed that the $10{\mu}$-turn coil having enough magnitude of magnetic field for the capture of RBC is possible to use as a biosensor for the detection of magnetic beads attached to RBC.

Development of Grinding/Polishing Process for Microstructure Observation of Copper melted Beads (구리 용융흔 미세조직 관측을 위한 연마/미세연마 프로세스 개발)

  • Park, Jin-Young;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.108-116
    • /
    • 2018
  • A melted bead microstructure can be divided into a deformed and undeformed layer. Measurement errors occur in the presence of a deformed layer, which should be removed through grinding/polishing whilst preserving the original structure. This paper proposes a grinding/polishing process to analyze the microstructure of copper melted beads. For the removal of the deformed layer, the correlation between the abrasive type/size, the polishing time and polishing rate was analyzed and the thickness of the deformed layer was less than $1{\mu}m$. The results suggest a new grinding/polishing procedure: silicon carbide abrasive $15{\mu}m$ (SiC P1200) 2 min, and $10{\mu}m$ (SiC P2400) 1 min; and diamond abrasive $6{\mu}m$ 8 min, $3{\mu}m$ 6 min, $1{\mu}m$ 10 min, and $0.25{\mu}m$ 8 min. In addition, a method of increasing the sharpness of the microstructure by chemical polishing with $0.04{\mu}m$ colloidal silica for 3 min at the final stage is also proposed. The overall grinding/polishing time is 38 min, which is shorter than that of the conventional procedure.

Comparison of Chemoembolization Outcomes Using 70-150 ㎛ and 100-300 ㎛ Drug-Eluting Beads in Treating Small Hepatocellular Carcinoma: A Korean Multicenter Study

  • Byung Chan Lee;Gyoung Min Kim;Juil Park;Jin Wook Chung;Jin Woo Choi;Ho Jong Chun;Jung Suk Oh;Dong Ho Hyun;Jung Ho Yang
    • Korean Journal of Radiology
    • /
    • v.25 no.8
    • /
    • pp.715-725
    • /
    • 2024
  • Objective: To evaluate the outcomes of drug-eluting bead transarterial chemoembolization (DEB-TACE) according to the size of the beads for the treatment of small hepatocellular carcinoma (HCC). Materials and Methods: This retrospective study included 212 patients with a single HCC ≤5 cm from five tertiary institutions. One hundred and nine patients were treated with 70-150-㎛ doxorubicin DEBs (group A), and 103 patients received 100-300-㎛ doxorubicin DEBs (group B). The initial tumor response (assessed between 3 weeks and 2 months after DEB-TACE), time to local tumor progression (TTLTP), restricted mean duration of complete response (RMDCR), rate of complications, incidence of post-embolization syndrome, and length of hospital stay were compared between the two groups. Logistic regression was used to analyze prognostic factors for initial tumor response. Results: The initial objective response rates were 91.7% (100/109) and 84.5% (87/103) for groups A and B, respectively (P = 0.101). In the subgroup analysis of tumors ≤3 cm, the initial objective response rates were 94.6% (53/56) and 78.0% (39/50) for groups A and B, respectively (P = 0.012). There was no significant difference in the TTLTP (median, 23.7 months for group A vs. 19.0 months for group B; P = 0.278 [log-rank], 0.190 [multivariable Cox regression]) or RMDCR at 24 months (11.4 months vs. 8.5 months, respectively; P = 0.088). In the subgroup analysis of tumors >3-cm, the RMDCR at 24 months was significantly longer in group A than in group B (11.8 months vs. 5.7 months, P = 0.024). The incidence of mild bile duct dilatation after DEB-TACE was significantly higher in group B than in group A (5.5% [6/109] vs. 18.4% [19/103], P = 0.003). Conclusion: DEB-TACE using 70-150-㎛ microspheres demonstrated a higher initial objective response rate in ≤3-cm HCCs and a longer RMDCR at 24 months in 3.1-5-cm HCCs compared to larger DEBs (100-300-㎛).

Synthesis of Resole-type Phenolic Beads via Suspension Polymerization Technique (현탁중합을 이용한 레졸형 구형 페놀입자의 합성)

  • Hahn, Dongseok;Kim, Daejung;Kim, Hongkyeong
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.279-284
    • /
    • 2013
  • The phenolic beads in macrosize range were obtained by suspension polymerization at $98^{\circ}C$ from phenol and formaldehyde in the presence of basic catalyst with a phenol to formaldehyde (P/F) range of 1:1~1:4, and they were carbonized to spherical carbon beads under nitrogen at $700^{\circ}C$. Thermal analysis on spherical phenolic beads obtained by suspension polymerization showed that the postcuring process is essential. In order to optimize the suspension polymerization, the effects of the P/F molar ratio, the pH of catalyst, and the molecular weight of stabilizer on the size distribution and yield of spherical phenol beads were examined separatively. The particle size was increased whereas the yield was decreased with P/F molar ratio. The increasing basicity of catalyst made the particle size to increase, while the molecular weight of stabilizer had more effect on the yield rather than on the particle size distribution. The thermal stability of the spherical phenolic beads obtained through postcure was also examined by TGA. The phenol beads of high P/F ratio still showed the weight loss at $220^{\circ}C$ even after postcure due to the high possibility of dibenzyl ether, while those of low P/F ratio showed the steady decrease in weight during $220^{\circ}C$ to $400^{\circ}C$, which showed that the optimal P/F ratio was 1:2.

Microencapsulation of SrAl2O4 : Eu2+,Dy3+ Phosphorescent Phosphor for Enhanced Visibility of Road Lanes (차선의 시인성 향상을 위한 SrAl2O4 : Eu2+,Dy3+ 축광 마이크로 캡슐화에 관한 연구)

  • Park, Jae Il;Jeong, Soo Hwan;Cheong, In Woo
    • Journal of Adhesion and Interface
    • /
    • v.17 no.3
    • /
    • pp.110-116
    • /
    • 2016
  • A decrease in the retro-reflectivity of glass-bead-covered road paint because of a rainwater film significantly reduces the visibility of drivers at night, and has been considered as a critical cause of traffic accidents. For enhanced visibility, the microencapsulation of hydrophobically modified $SrAl_2O_4:Eu^{2+}$,$Dy^{3+}$ phosphorescent phosphor was carried out via suspension polymerization of methyl methacrylate (MMA). The effects of surface modification agent and radical initiator types, loading amount of phosphorescent phosphor, and microcapsule size on the phosphor content ($W_{TGA}$) in the luminous poly(methyl methacrylate) (PMMA) microcapsules were investigated by thermogravimetric analyses (TGA). It was found that the $W_{TGA}$ value was ranged from 7 wt% to 81 wt%, which suggests suspension polymerization is suitable for the preparation of luminous microcapsules with a wide range of phosphor content. At a lower loading amount of phosphor, the $W_{TGA}$ value obviously increased as the microcapsule size decreased; however, the $W_{TGA}$ values with a higher loading amount of phosphor were less affected by the microcapsule size. The luminous microcapsules with the size range of $425{\sim}710{\mu}m$ were collected and tested as a luminous road lanes. It was found that luminance intensities of the microcapsule-coated plates remained higher than $300mcd/m^2$ for up to 100 s in darkness after 20 min of light emitting diode lamp irradiation. The results suggest that the luminous microcapsules can be a candidate for the replacement of glass beads for enhanced visibility of drivers.

Evaluation of Genome Based Estimated Breeding Values for Meat Quality in a Berkshire Population Using High Density Single Nucleotide Polymorphism Chips

  • Baby, S.;Hyeong, K.E.;Lee, Y.M.;Jung, J.H.;Oh, D.Y.;Nam, K.C.;Kim, T.H.;Lee, H.K.;Kim, Jong-Joo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.11
    • /
    • pp.1540-1547
    • /
    • 2014
  • The accuracy of genomic estimated breeding values (GEBV) was evaluated for sixteen meat quality traits in a Berkshire population (n = 1,191) that was collected from Dasan breeding farm, Namwon, Korea. The animals were genotyped with the Illumina porcine 62 K single nucleotide polymorphism (SNP) bead chips, in which a set of 36,605 SNPs were available after quality control tests. Two methods were applied to evaluate GEBV accuracies, i.e. genome based linear unbiased prediction method (GBLUP) and Bayes B, using ASREML 3.0 and Gensel 4.0 software, respectively. The traits composed different sets of training (both genotypes and phenotypes) and testing (genotypes only) data. Under the GBLUP model, the GEBV accuracies for the training data ranged from $0.42{\pm}0.08$ for collagen to $0.75{\pm}0.02$ for water holding capacity with an average of $0.65{\pm}0.04$ across all the traits. Under the Bayes B model, the GEBV accuracy ranged from $0.10{\pm}0.14$ for National Pork Producers Council (NPCC) marbling score to $0.76{\pm}0.04$ for drip loss, with an average of $0.49{\pm}0.10$. For the testing samples, the GEBV accuracy had an average of $0.46{\pm}0.10$ under the GBLUP model, ranging from $0.20{\pm}0.18$ for protein to $0.65{\pm}0.06$ for drip loss. Under the Bayes B model, the GEBV accuracy ranged from $0.04{\pm}0.09$ for NPCC marbling score to $0.72{\pm}0.05$ for drip loss with an average of $0.38{\pm}0.13$. The GEBV accuracy increased with the size of the training data and heritability. In general, the GEBV accuracies under the Bayes B model were lower than under the GBLUP model, especially when the training sample size was small. Our results suggest that a much greater training sample size is needed to get better GEBV accuracies for the testing samples.

Linkage Disequilibrium Estimation of Chinese Beef Simmental Cattle Using High-density SNP Panels

  • Zhu, M.;Zhu, B.;Wang, Y.H.;Wu, Y.;Xu, L.;Guo, L.P.;Yuan, Z.R.;Zhang, L.P.;Gao, X.;Gao, H.J.;Xu, S.Z.;Li, J.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.6
    • /
    • pp.772-779
    • /
    • 2013
  • Linkage disequilibrium (LD) plays an important role in genomic selection and mapping quantitative trait loci (QTL). In this study, the pattern of LD and effective population size ($N_e$) were investigated in Chinese beef Simmental cattle. A total of 640 bulls were genotyped with IlluminaBovinSNP50BeadChip and IlluminaBovinHDBeadChip. We estimated LD for each autosomal chromosome at the distance between two random SNPs of <0 to 25 kb, 25 to 50 kb, 50 to 100 kb, 100 to 500 kb, 0.5 to 1 Mb, 1 to 5 Mb and 5 to 10 Mb. The mean values of $r^2$ were 0.30, 0.16 and 0.08, when the separation between SNPs ranged from 0 to 25 kb to 50 to 100 kb and then to 0.5 to 1 Mb, respectively. The LD estimates decreased as the distance increased in SNP pairs, and increased with the increase of minor allelic frequency (MAF) and with the decrease of sample sizes. Estimates of effective population size for Chinese beef Simmental cattle decreased in the past generations and $N_e$ was 73 at five generations ago.