• Title/Summary/Keyword: Batcher plant

Search Result 25, Processing Time 0.019 seconds

Optimal location of Batcher Plant using Modified Steiner point (수정된 Steiner Point를 이용한 Batcher Plant의 최적 위치 선정)

  • Ha, Kwon-Yeol;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.39-46
    • /
    • 2015
  • REMICON(Ready Mixed Concrete), the most essential material of construction work, is produced from facility called "Batcher plant." In order to produce Remicon, Batcher Plant needs to be supplied with basic raw material such as ballast, sand, cement, admixture and water. In remicon industry, overland transport vehicles are used during the whole manufacturing process from producing to infilling at the construction site. Thus, the transportation cost sums up be to 20 percent of whole manufacturing cost and transport capacity and distance travelled have direct and major effect on manufacturing costs. This paper suggests a method to find optimal location of batcher plant using modified Steiner point, suggesting the most effective and flexible connection through among construction site, aggregate, cement and remicon producing plant. This paper also proposes reducing of transport cost at maximum 60% by calculation through optimized plant location. The modified Steiner point theory proposed in this paper also can be applied to optimal location of a $2^{ry}$ substation or MCC panel for minimizing of power loss, voltage drop, line distance and etc.

An Experimental Study on the High Early Strength Development Properties of Concrete according to Batcher Plant Test and Mock-up Test (배쳐플랜트배합시험 및 실대부재시험을 통한 콘크리트의 조기강도 발현특성에 관한 실험적 연구)

  • Lee, Ji-Hwan;Lee, Jong-suk;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.1-5
    • /
    • 2008
  • In this study, batcher plant composition test and mock-up test were carried out to conduct comparison and analysis on flow behavior and strength properties of concrete at early age. As a result, it was found that slump and amount of air in batcher plant composition test reached the target range. As for compressive strength, composition using HESPC showed the most excellent strength development. In mock-up test which was carried out to find out the strength properties, two methods with specimen and core test body both revealed HESPC as the most excellent composition. However, strength estimation with ultrasonic survey presented less reliable data. As a result of the previously conducted indoor composition test and the mock-up test in this study, target performance of concrete at early age was 4day/cycle. It was found that the optimum conditions that meet the required strength, 5MPa/18hr and 14MPa/36hr in mullion and transom are; curing temperature above 15℃, W/B 45%, unit-water 165kg/㎥ and CHC cement.

  • PDF

The evaluation of Mechanical properties of Strain Hardening Cement-based composites manufactured at batcher plant (배처플랜트에 의해 제조된 SHCC의 역학적 성능 평가에 관한 연구)

  • Lim, Chang-Hyuck;Kim, Young-Sun;Kim, Young-Duck;Jeong, Jae-Hong;Lee, Seung-Hoon;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.93-96
    • /
    • 2009
  • This study is to examine a change of quality and a material performance of fiber reinforced cement composite for mass production. It is necessary to make Strain-hardening cementitious composite(SHCC) by batcher plant for ready-mixed concrete and use the performance of SHCC which made based on laboratory level. This study makes a comparative performance of press and mechanics that is the property of Strain-hardening by direct tension. In case of making by batcher plant. This experiment has demonstrated that even if it takes long after being mixed small and compared with the one which made based on laboratory, it has a tendency to be dissatisfied with fiver's dispersion and lower its performance of Strain-hardening. The reason why the material performance of SHCC for mass production went down is through SHCC that mixed sometimes matrix's viscosity and fiber's dispersion.

  • PDF

The Application of High Strength Concrete in Batcher Plant and its Workability (레미콘 공장에서 적용 가능한 고강도 콘크리트 및 시공성에 관한 연구)

  • Kim, Jeong-Sik;Kim, Bong-Hyun;Jung, Jin;Lee, Jae-Sam;Kang, Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.69-74
    • /
    • 1998
  • Concrete has a many problems to apply high rise building of its low strength to weight and low ductility, compared to steel products. Therefore, it is necessary to make high strength concrete for applying to night rise building. In the experiment, the high strength concrete was made in variable of unit weight of binder, water to binder ratio(W/B), and sand to aggregate ratio(S/a) using batcher plant. As a result, it was possible to make high strength concrete using only materials for ordinary concrete without admixtures such like silica fume in batcher plant.

  • PDF

The site application with 700kg/$\textrm{cm}^2$ high strength concrete (700kg/$\textrm{cm}^2$ 고강도 콘크리트의 현장적용)

  • 권영호;박정국;이보근;박칠림
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.124-131
    • /
    • 1993
  • A successful site application with 700kg/$\textrm{cm}^2$ ultra-high strength concrete was made by research team of Daewoo Institute of Construction Technology in Jinhae. Trial mixings of concrete, the productivity of batcher plant, the elapsed time and the pumpability had been investigated for the site condition, before the site application. As results, the efficiency of production by automatic batcher plant systems was improved and the method of quality control was estabilished for the security of fluidity due to the elapsed time, the pumping and consolidation and so on. The concrete strength cores as well as cylinders was showed more than 700kg/$\textrm{cm}^2$ for the required age. And this study would be provided valuable data base for the practical utilization of high strength concrete. Further, this study would be given new possibilities of high rise RC constructions.

  • PDF

A Study on Applicability Evaluation according to Strength Range of High-Strength Fire Resistance Concrete (고강도 내화 콘크리트의 강도 영역에 따른 현장 적용성 평가에 관한 연구)

  • Jang, Jong-Min;Baek, Young-Un;Yuk, Tae-Won;Park, Dong-Soo;Lee, Hang-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.177-178
    • /
    • 2023
  • In this study, the mass production process was simulated using a 1m3 batcher plant to evaluate the application of high-strength fire resistance concrete. The strength ranges of concrete were set to 50, 60, 70, and 80 MPa, and each concrete mix proportions was selected through preliminary experiments in the laboratory. For the selected concrete mix proportions, after the mixer load value was stabilized in the batcher plant, the slump flow and air content of the fresh concrete were evaluated, and the compressive strength was evaluated up to 56 days. As a result of the experiment, both the slump flow and air content of the fresh concrete satisfied the target performance, and in the case of compressive strength, 50 and 60 MPa satisfied the target performance at 28 days and 70 and 80 MPa at 56 days.

  • PDF

An Experimental Study on the Ready-Mixed Concrete Manufacture Performance of Ultra-High Strength Concrete using the Crushed Sand (부순모래를 사용한 초고강도 콘크리트의 레미콘 제조성능에 관한 실험적 연구)

  • Rho, Hyoung-Nam;Lim, Hyon-Ung;Choi, Se-Jin;Lee, Seong-Yeon;Lee, Sang-Soo;Song, Ha-Youg
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.25-28
    • /
    • 2007
  • In this study we measured the changes according to time respectively on the basis of 0, 30, 60 and 90 minutes, taking into consideration the decline in fluidity of concrete according to elapsed time to analyze manufacturing capability of batcher plant according to elapsed time of ready-mixed concrete manufactured in batcher plant, and offer basic data for mixture design of ultra-high strength concrete. The proportion of water-binder was 23.55, water content was 160kg/m3, proportion of replacement of crushed sand was 0, 20 and 40% at 3 level, and we applied to the same condition of triaxial component using blast furnace slag powder and silica fume as admixture. And to meet the demand of certain fluidity, we measured respectively on property before and after hardening of ultra-high strength concrete using superplasticizer. As a result of experiment, before hardening of ultra-high strength concrete showed the best fluidity in conditions of crushed sand replacement rates of 20% and superplasticizer composition of 1.95%, but it appeared that fluidity drops as time goes by in the same composition condition. And it appeared that when it comes to hardened, the changes of compression strength according to elapsed time by crushed sand replacement rates were within 1MPa. Therefore, it turned out that the difference of strength according to elapsed time was low and compression strength of 280dys in composition mentioned above appeared highly as 88MPa.

  • PDF

Mix Design of Exposed Concrete Wall using Self Compacting Concrete (노출 구조물 벽체에 적용하기 위한 무다짐 콘크리트의 최적배합설계)

  • 손유신;이승훈;김규동;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.555-560
    • /
    • 2002
  • The structure of Chosun-ilbo Boopyung factory was desined as exposed concrete. The self compacting concrete(non-vibrating concrete) must be applied to this case because the exposed concrete wall is very thin(200mm) and high(6m), Laboratory tests and semi mock-up test were performed for optimum mix design of the self compacting concrete. As a result, the optimum mixes were observed at the 3-component types(ope, fly-ash, slag powder) that Vp$\geq$0.175, Vw/Vp$\geq$0.95, W=170~175$kgf/m^3$ and B=500~540$kgf/m^3$ Based on this result. we make plan that the pilot productions of batcher plant, the full-scale mock up tests and site application.

  • PDF

An Experiment on the Structure Application of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집을 이용한 한중콘크리트의 구조체 적용 실험)

  • 김경민;손성운;김기철;오선교;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.21-26
    • /
    • 2002
  • This paper is intended to verify the efficiency of anti-freeze agent and insulating form by analyzing the temperature history and the property of strength-increase about the concrete that is placed in the insulating form and normal form, using new type anti-freeze agent in batcher plant According to the results about the temperature history, while the lowest temperature shows 3$^{\circ}C$ in case of normal concrete + euroform, 4$^{\circ}C$ in case of normal concrete + insulating form, it shows 6$^{\circ}C$ in anti-freeze agent + the insulating form, so the effect is most favorable. The compressive strength with mixing anti-freeze agent or not, shows high in order of standard curing, structure-managing and open air-placed specimen and the concrete mixing anti-freeze agent shows the highest compressive strength-increase.

  • PDF