• 제목/요약/키워드: Batch processing

Search Result 290, Processing Time 0.189 seconds

초고추장첨가 멸치(Engraulis japonica)육젓필레통조림의 제조 및 특성 (Processing and Characteristics of Canned Salt-fermented Anchovy Engraulis japonica Fillet using Red Pepper Paste with Vinegar)

  • 권순재;윤문주;이재동;강경훈;공청식;제해수;정제헌;김정균
    • 한국수산과학회지
    • /
    • 제47권6호
    • /
    • pp.726-732
    • /
    • 2014
  • A traditional Korean seafood (fermented anchovy) is made from the muscle and viscera of anchovies Engraulis japonica. This study was undertaken to investigate the effect of retorting condition on the quality of canned, salt-fermented anchovy fillet using red pepper paste with vinegar. Salt-fermented anchovy fillets were prepared by fermenting anchovies with salt (15%) at $5^{\circ}C$ for 15 days, and then cold air drying the fillets for 1 hour. Each batch of dried fermented anchovy fillets (60 g) was filled with 35 g of mixed red pepper paste with vinegar (red pepper paste 64%, vinegar 2%, starch syrup 13%, sugar 14%, coke 6%, soju 0.4%, crushed garlic 0.3%, ginger 0.3%), placed in a can (RR-90), seamed using a vacuum seamer, and sterilized for either Fo 9 or 11 min in a steam system retort at $121^{\circ}C$. After sterilization, we measured the pH, total volatile basic nitrogen (TVB-N), amino-N, color value (L, a, b), texture profile, thiobarbituric acid (TBA) value, sensory evaluation, and viable bacterial count of the canned fillets. We did not detect viable bacterial counts in cans subjected to either sterilization treatment, and there was no difference in physicochemical and sensory quality between the two. In fact, most sensory evaluators reported difficulty distinguishing the products. Thus, our results show that sterilization for Fo 9 min is preferable to that for Fo 11 min in the preparation of canned salt-fermented anchovy fillet using red pepper paste with vinegar.

영지의 액체배양에 있어서 균사체 형태에 미치는 Ammonium Phosphate의 영향 (Influence of Ammonium Phosphate on Mycelial Morphology during Submerged Cultivation of Ganoderma lucidum)

  • 이규민;이신영
    • 한국균학회지
    • /
    • 제29권2호
    • /
    • pp.91-98
    • /
    • 2001
  • 버섯의 액체배양에 의한 균사체 및 세포외 다당 발효의 안정성과 생산성 증가를 도모하기 위하여, 영지(Ganoderma lucidum ASI 7004)의 액체배양 중, 배지조성($0{\sim}11\;g/l$의 ammonium)을 달리하여 균사체 형태 및 분화의 경시변화를 영상분석 시스템을 이용하여 분석하였다. 배지 조성 및 배양 조건에 따른 균사체 형태의 배양경시변화를 영상분석한 결과, non-branched long filamentous mycelium, non-branched short mycelium, branched long filamentous mycelium, branched short mycelium, entangled mycelium 및 각종 clump의 필라멘트 형태와, smooth pellet, rough pellet 및 hollow rough pellet의 펠렛 형태 등, 다양한 형태를 관찰할 수 있었다. Ammonium ion이 낮은 경우에는 필라멘트 형태의 균사 생육이 주인 반면, 높은 농도로 갈수록 펠렛 형태의 균사 생육이 주로 관찰되었다. 이러한 형태의 변화를 수치화 하는 수단으로 fractal 차원을 이용하여 형태를 분류한 결과, 11 g/l의 ammonium phosphate 농도에서 주로 나타나는 균사형태의 fractal 차원을 이용하여 형태를 분류한 결과, 11 g/l의 ammonium phosphate 농도에서 주로 나타나는 균사형태의 fractal 차원은 1.05 이었으나(펠렛형), ammonium phosphate의 결핍 시에 주로 나타나는 균사 형태의 fractal 차원은 1.3이었다(필라멘트형). 또 필라멘트형 및 펠렛형 균사체가 공존할 때의 fractal 차원은 1.16으로, 이들의 중간 값을 나타내었다. 따라서, fractal 차원은 균사 형태의 변화를 측정하는 지표 값으로 매우 유용할 것으로 생각되었다. 또 원형도는 펠렛형 균사체의 표면에서 균사 생육 정도를 판정하는데 유용한 것으로 나타났다.

  • PDF

임의 두 지점의 웹 카메라와 퍼지 가비지 모델을 이용한 사용자의 의미 있는 동작 검출 (Gesture Spotting by Web-Camera in Arbitrary Two Positions and Fuzzy Garbage Model)

  • 양승은
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제1권2호
    • /
    • pp.127-136
    • /
    • 2012
  • 각종 지능형 전자장비의 개발과 사용자 편의성 증대를 위해 영상기반의 손 동작 인식시스템이 다양하게 개발, 적용되고 있다. 손 동작 인식을 위해 손의 3차원 위치를 계산하고 오 동작 방지를 위해 명령 동작을 다른 유사동작과 구분하여 정확히 검출해야 한다. 본 논문에서는 설치가 쉽고 저렴한 비용으로 3차원 위치를 계산하는 시스템과 다양한 유사 동작 중 정의된 동작만을 검출해 내는 방법에 대해 다룬다. 팬/틸트 가능한 두 대의 USB 카메라와 표식을 이용하여 카메라를 임의의 위치에 두더라도 부착된 표식을 통해 자동으로 두 카메라간 상대위치를 구해 3차원 위치를 계산할 수 있다. 사용자의 명령 동작을 다른 유사 동작과 구분하기 위해 퍼지 가비지 모델을 개발 하였는데 퍼지 명령모델과 가비지 모델 두 가지를 이용하여 행동 인식에 대한 가변적 문턱 값을 구할 수 있다. 또한 두 단계의 적응 과정을 통해 각 사용자마다 다르게 나타나는 행동 특성 및 동일 사용자가 환경에 따라 다르게 나타내는 행동 특성을 반영 하여 성능을 개선한다. 개발된 시스템을 5명의 사용자를 대상으로 실험을 실시하였는데 명령 동작과 하나의 유사동작만 있을 경우 95% 이상, 다양한 유사동작이 혼재되어 있을 경우 85%이상의 인식률(명령 동작 검출)을 보였다.

다중플립 오류정정을 위한 새로운 QECCs (New QECCs for Multiple Flip Error Correction)

  • 박동영;김백기
    • 한국전자통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.907-916
    • /
    • 2019
  • 본 논문은 CNOT 게이트만을 사용해 모든 다중비트플립 오류들로부터 표적큐비트를 완벽하게 보호할 수 있는 새로운 5-큐비트 다중비트플립코드를 제안하였다. 제안한 다중비트플립코드는 기존의 단일비트플립코드에서와 같이 근원오류부에 Hadamard 게이트 쌍들을 임베딩 할 경우에 쉽게 다중위상플립코드로 확장될 수 있다. 본 논문의 다중비트플립코드와 다중위상플립코드는 4 개 보조큐비트들에 의한 상태벡터 오류정보를 공유한다. 이 4-큐비트 상태벡터들은 Pauli X와 Z 정정이 수반되는 모든 다중플립오류들이 특정 근원오류를 공통으로 포함하는 특성을 반영한다. 이 특성을 이용해 본 논문은 Pauli X와 Z 근원오류의 검출과 정정을 단 3개의 CNOT 게이트로 배치 처리함으로써 다중플립 오류정정을 위한 QECC 설계에도 불구하고 저비용 실현이 가능함을 보였다. 본 논문이 제안한 5-큐비트 다중비트플립코드와 다중위상플립코드는 100% 오류정정율과 50% 오류판별율 특성을 보였다. 이 논문에 제시된 모든 QECC는 QCAD 시뮬레이터를 사용해 검증되었다.

열처리 장비의 Safety를 위한 딥러닝 기반 영상처리 시스템 (Image Processing System based on Deep Learning for Safety of Heat Treatment Equipment)

  • 이정훈;이로운;홍승택;김영곤
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권6호
    • /
    • pp.77-83
    • /
    • 2020
  • 열처리 시설은 뿌리산업 중에서 고열에 의한 열악한 환경과 긴 근로시간 등으로 원격 IOT 시스템의 적용 범위가 확대되는 상황이다. 이러한 열처리 공정 환경에서 IOT 미들웨어는 사물인터넷 기기(센서 등)의 데이터 정보를 해석하고 관리하며 제어할 수 있는 중추적 역할이 요구된다. 그간 열처리 원격에서 제어하는 시스템은 현장 상황에 대한 전반적 감시 없이 작업자의 일괄 시스템 명령으로 운영되었다. 하지만 열처리 시설의 안전성과 정밀한 제어를 위해서는 다양한 센서 컨트롤과 주변 작업환경 인지가 필요하다. 본 논문에서 제시한 열처리 안전지원 시스템은 그에 대한 해결책으로 열화상 감지를 통해 열처리로의 작업인력 접근을 파악하고 원격에서 작업 가동 시 열처리 장비의 Safety를 위한 지원시스템을 제안하였다. 또한 일반적인 고정된 열점 감시 기반 열화상 분석보다 더욱 빠르고 정확한 인식을 위해 DNN 딥러닝 네트워크를 활용한 OPEN CV 기반 열화상 분석 시스템을 구성하였다. 이를 통해 열처리 산업에 특성화된 안전관리 지원과 향후 열처리 환경에서 범용적으로 활용 할 수 있는 시스템을 제안하고자 한다.

국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가 (Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro))

  • 오윤정;김지영;석재동
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.197-202
    • /
    • 2010
  • 목적: 각 검사실에서는 임상의 신속한 검사 결과 보고 요청에 부응하고 검사 결과의 신뢰도 및 효율성을 증가시키기 위해 자동화 장비를 많이 사용한다. 국산 자동화 장비는 기존 자동화 장비의 단점을 개선, 보완하여 폭넓은 수행능을 가진 국산 자동화 장비이다. 본 연구에서 국산 자동화 장비와 기존 자동화 장비와의 상관성 및 분석능력을 평가하여 검사실에서의 결과보고시간 단축에 대한 유용성과 신뢰성을 알아보고자 하였다. 대상 및 방법: 2009년 9월 삼성서울병원에서 갑상선 호르몬 검사(TT3, TSH, FT4)가 의뢰된 환자를 대상으로 저농도에서 고농도 검체 100개씩 국산 자동화 장비와 RIA-mat 280을 사용하여 상관성을 알아보았다. 국산 자동화 장비의 부분별 평가로 첫째, Tip부분은 정확도, 회수율, 검체 간 상호 오염도를 측정하였다. 둘째, Incubator부분은 회전수(RPM)와 회전축 원경(mm)에 따른 최적의 검사반응 조건을 알아보았다. 검체처리 속도를 분석하기 위해 특정기간의 검사결과 보고시간을 조사하였다. 결과: 국산 자동화 장비와 RIA-mat 280의 상관계수($R^2$)는 TT3 0.98, TSH 0.99, FT4 0.92로 좋은 상관관계를 보였다. Tip의 평가로 정밀도 CV 0.38 %(1번 Tip), CV 0.39 %(2번 Tip), 정확도 98.3 %(1번 Tip), 98.6 %(2번 Tip). 검체 간 상호 오염도는 0.01 %(1번 Tip), 0 %(2번 Tip)로 검체 간 상호 오염도가 거의 없었다. Incubator 조건에서 회전수(RPM)와 회전수 원경(mm) 500 RPM의 1.0 mm, 1.5 mm와 600 RPM의 1.0 mm, 1.5 mm 중 600 RPM의 1.0 mm가 최상의 조건임을 알 수 있었다. 기존의 자동화 장비에서 6회/일 시행되던 검사가 최대20회/일로 늘어남으로써 검체 접수에서 결과보고까지 소요시간이 평균 4.20시간에서 평균 2.19시간으로 약 2시간 단축되었다. 결론: 국산 자동화 장비(Gamma Pro) 사용으로 결과보고 시간이 평균 2.19시간으로, 약 2시간 단축되는 결과를 얻었다. 본 기기는 일정시간당 대량 검체 처리능력이 뛰어나고 실용성을 갖춘 효율적인 장비라고 여겨진다. 검사결과 보고 시간 단축으로 인해 응급환자의 신속한 진단과 외래환자의 진료대기시간 단축에 유용할 것이다.

  • PDF

찹쌀 첨가에 따른 전통발효주의 품질 특성 (Quality Characteristics of Korean Traditional Rice Wine with Glutinous Rice)

  • 이영승;김한나;엄태길;김성환;최근표;김미숙;유성률;정윤화
    • 한국식품영양과학회지
    • /
    • 제42권11호
    • /
    • pp.1829-1836
    • /
    • 2013
  • 찹쌀 첨가량(0, 10, 15, 20%)에 따른 술덧을 제조하여 발효 10일 동안의 알코올 함량, pH 및 총산, 총당 함량, 환원당 함량, 유기산 함량, 유리당 함량 등의 이화학적 특성과 미생물 변화를 알아보고 발효주의 관능적 특성을 조사하였다. 알코올 함량은 발효 1일째 9.1~9.7%에서 발효 종료일 10일째 15.8~17.1%로 증가하였으나 각 실험군 간에 유의적인 차이는 없었다. 총균, 유산균, 효모수는 알코올 생성속도와 비례하여 발효초기에는 증가하면서 발효후기에는 감소하는 경향을 나타내었다. pH는 담금 직후 5.30~5.46에서 발효 1일째 3.89~3.91로 감소한 후, 다시 증가하기 시작하여 발효 종료일인 10일째 모두 4.5 수준이었다. 총산 함량은 발효 3일째 0.14~0.16%에서 발효 5일째 0.18~0.19%로 증가하였다. 이는 지속적인 유산균의 생장으로 인한 젖산의 누적과 효모에 의한 산 생성으로 발효 3~5일째 총산 함량도 증가한 것으로 추측된다. 총효모수는 2단 담금 이후 유의적으로 증가하였다가 발효 과정을 거치면서 발효 종료일(발효 10일째)에 유의적으로 점차 감소하였다. 환원당은 발효 1일째 1.1~1.2%에서 발효 2일째 0.9~1.1%로 유의적으로 감소하였다가 알코올 발효보다 전분분해에 의한 당 생성 속도가 증가하여 발효 종료일인 10일째 2.8~3.3%로 증가하였다. 총당 함량은 발효 초기 당분이 술덧 중에 생육하는 효모나 유산균 등의 발효기질로 이용하여 발효 종료일 10일째에는 감소하였고, 찹쌀 15%첨가군이 유의적으로 가장 높았다. 당화효소인 amylase에 의해 전분질의 분해로 포도당이 비교적 많이 생성되어 술덧의 주요 유리당이었으며, 유기산에서는 succinic acid 함량이 가장 높았다. 발효주의 관능평가에서 찹쌀 15%첨가군은 전반적인 기호도(4.8점)와 목넘김(4.3점)에서 유의적으로 가장 높게 평가되었다. 묘사분석에서는 찹쌀 15%첨가군이 단맛 강도가 8.6으로 유의적으로 가장 높았으며, 이는 찹쌀 15%첨가군의 높은 총당 함량과 관계가 있는 것으로 판단된다.

소셜네트워크 빅데이터를 활용한 코로나 19에 따른 프로야구 관람문화조사 (Professional Baseball Viewing Culture Survey According to Corona 19 using Social Network Big Data)

  • 김기탁
    • 한국엔터테인먼트산업학회논문지
    • /
    • 제14권6호
    • /
    • pp.139-150
    • /
    • 2020
  • 본 연구의 자료처리는 텍스톰(textom)과 소셜미디어의 단어를 중심으로 3가지 영역인 '코로나 19와 프로야구', '코로나 19와 프로야구 무관중', '코로나 19와 프로스포츠'에 대해 웹 환경에서 데이터 수집과 정제작업을 실시한 후 일괄 처리하였으며, 이를 시각화하기 위해 Ucinet6프로그램을 활용하였다. 구체적으로 웹 환경의 수집은 네이버, 다음, 구글의 채널을 활용하였고, 추출된 단어들 중 전문가회의를 통해 30개의 단어로 요약 정리하여 최종 연구에 활용하였다. 30개의 추출된 단어를 매트릭스를 통해 시각화하였으며, 단어의 유사성과 공통성의 군집을 파악하기 위해 CONCOR분석을 실시하였다. 분석결과 코로나 19와 프로야구에 관련된 군집은 1개의 중심클러스터와 5개의 주변클러스터로 구성되었고 코로나 19여파에 따른 프로야구 개막과 관련된 내용을 주로 검색하고 있는 것으로 나타났다. 코로나 19와 프로야구 무관중에 관련된 군집은 1개의 중심 클러스터와 5개의 주변클러스터로 구성되었으며, 코로나 19에 따른 프로야구 경기와 관련된 프로야구 입장의 키워드를 주로 검색하고 있는 것으로 나타났다. 코로나 19와 프로스포츠에 관련된 군집은 1개의 중심클러스터와 5개의 주변클러스터로 구성되었으며, 코로나 19의 여파에 따른 프로스포츠 시작과 관련된 키워드를 주로 검색하고 있는 것으로 나타났다. 이를 종합해보면 포스트 코로나 시대의 프로야구는 많은 변화가 있을 것이라 예상된다. 특히 응원문화는 관중들이 원하는 정도의 만족감은 없겠지만 관중들이 누릴 수 있는 직접관람의 기회를 누리기 위해 야구장에서도 코로나 19를 극복하기 위한 하나의 일상으로의 행동강령이 잘 유지되어야 할 것이다. 관람문화 또한 라이브커머스, AR/VR, O4O(Online for Offline)등의 4차 산업혁명의 기술도입으로 현장감 있는 쌍방향 소통이 가능한 인터렉티브 소통의 디지털이 구현돼야 할 것이다. 포스트 코로나 시대는 프로스포츠에도 새로운 형태의 패러다임이 구축될 것이다. 랜선 응원, SNS를 활용한 응원, 실시간 동시시청, 라이브 채팅응원, 편파중계 등 다양한 형태의 응원문화가 새로운 창작 콘텐츠 형태로 진화할 것이며, 팬들의 욕구를 충족할 수 있는 새로운 형태의 패러다임이 구축돼야 하겠다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF