By use of a simple two-point extrapolation scheme estimating the correlation energies of the molecules along with the basis sets specifically targeted for extrapolation, we have shown that the MP2 basis set limit binding energies of large hydrogen-bonded complexes can be accurately predicted with relatively small amount of computational cost. The basis sets employed for computation and extrapolation consist of the smallest correlation consistent basis set cc-pVDZ and another basis set made of the cc-pVDZ set plus highest angular momentum polarization functions from the cc-pVTZ set, both of which were then augmented by diffuse functions centered on the heavy atoms except hydrogen in the complex. The correlation energy extrapolation formula takes the (X+1)-3 form with X corresponding to 2.0 for the cc-pVDZ set and 2.3 for the other basis set. The estimated MP2 basis set limit binding energies for water hexamer, hydrogen fluoride pentamer, alaninewater, phenol-water, and guanine-cytosine base pair complexes of nucleic acid by this method are 45.2(45.9), 36.1(37.5), 10.9(10.7), 7.1(6.9), and 27.6(27.7) kcal/mol, respectively, with the values in parentheses representing the reference basis set limit values. A comparison with the DFT results by B3LYP method clearly manifests the effectiveness and accuracy of this method in the study of large hydrogen-bonded complexes.
We compare the relative usefulness of common basis functions and numerical integration methods in representing complex resonance state encountered in the molecular scattering problem of aluminum dimer electronic predissociation. Specifically, the basis set size and computing CPU times are monitored in order to find the minimum requirement for ensuring the modest accuracy of calculated resonance energies (0.1 $cm^{-1}$) for more than 100 resonance states. The combination of the so-called one-dimensional box eigenfunctions and energy-dependent boundary functions are found to be most efficient if integration is done using the basis set quadrature rules.
Proceedings of the Korean Society for Noise and Vibration Engineering Conference
/
2007.11a
/
pp.1430-1436
/
2007
A principal components analysis (PCA) of the median head-related impulse responses (HRIRs) in the CIPIC HRTF database reveals that the individual HRIRs can be adequately reconstructed by a linear combination of 12 orthonormal basis functions. These basis functions can be used generally to model arbitrary HRIRs, which are not included in the process to obtain the basis functions. To clarify whether these basis functions can be used to model other set of arbitrary HRIRs, an numerical error analysis for modeling and a series of subjective listening tests were carried out using the measured and modeled HRIRs. The results showed that the set of individual HRIRs, which were measured in our lab using different measurement conditions, techniques, and source positions, can be well modeled with reasonable accuracy. Furthermore, all subjects reported not only the accurate vertical perception but also the front-back discrimination with the modeled HRIRs based on 12 basis functions. However, as less basis functions were used for HRIR modeling, the modeling accuracy and localization performance deteriorated.
We have studied the structures and stabilities of Au6 to explore the origin of the large discrepancy between relative energies obtained from the density functional theory (DFT) and ab initio correlated levels of theory. The MP2 methods significantly overestimate the stability of the non-planar isomer when the double-$\zeta$ polarization quality of basis sets, such as LANL2DZ+1f and CEP31G+1f, are used. However, we show that such preference for the non-planar structure at the MP2 level mainly originates from the large basis set superposition error.
Transactions of the Korean Society for Noise and Vibration Engineering
/
v.18
no.4
/
pp.448-457
/
2008
A principal components analysis (PCA) of the median-plane head-related impulse responses (HRIRs) in the CIPIC HRTF database reveals that the individual HRIRs in the median plane can be adequately reconstructed by a linear combination of 12 orthonormal basis functions. These basis functions can be used to model arbitrary median-plane HRIRs, which are not included in the process to obtain the basis functions. Memory size can be reduced up to 5-fold depending on the number of HRIRs to be modeled. To clarify whether these basis functions can be used to model other set of arbitrary median plane HRIRs, a numerical error analysis for modeling and a series of subjective listening tests were carried out using the measured and modeled HRIRs. The results showed that the set of individual HRIRs in the median plane, which were measured in our lab using different measurement conditions, techniques, and source positions, can be modeled with reasonable accuracy. All subjects, involved in the subjective listening test, reported not only the accurate vertical perception but also the front-back discrimination with the modeled HRIRs based on 12 basis functions.
For the specific detection of human Parvovirus B19 (HuPaV-B19), we designed ten specific PCR primers from 3,800~4,500 nucleotides of HuPaV-B19 complete genome (NC_000883.2). Seventeen candidate PCR primer sets for specific detecting HuPaV-B19 were constructed. In specific reaction of HuPaV-B19, seventeen PCR primer sets showed specific band, however five PCR primer sets were selected basis of band intensity, amplicon size and location. In non-specific reaction with seven reference viruses, four PCR primer sets showed non-specific band, however one PCR primer set is not. Detection sensitivity of final selective PCR primer set was $100fg/{\mu}L$ for 112 minute, and PCR amplicon is 539 base pairs (bp). In addition, nested PCR primer set was developed, for detection HuPaV-B19 from a low concentration of contaminated samples. Selection of nested PCR primer set was basis of sensitivity and groundwater sample tests. Detection sensitivity of final selective PCR and nested PCR primer sets for the detection of HuPaV-B19 were $100fg/{\mu}L$ and $100ag/{\mu}L$ basis of HuPaV-B19 plasmid, it was able to rapid and highly sensitive detection of HuPaV-B19 than previous reports. We expect developed PCR primer set in this study will used for detection of HuPaV-B19 in various samples.
Proceedings of the Korean Society for Technology of Plasticity Conference
/
1999.08a
/
pp.126-131
/
1999
In order to reduce the length of off-gauge at FGC(Flying gauge change) point, We adopted dynamic set up in No. 4 cold rolling mill. The conventional set-up of FGC(Flying gauge change) was calculated on the basis of preset values in the process control computer, so the difference between actual strip thickness and preset thickness cause long off-gauge. The dynamic SET-UP control was calculated on the basis of actual strip thickness of FGC(Flying gauge change) point from X-ray gauge of mill entry and No.i stand. We applied dynamic SET-UP control in September last year. Compare to the previous result, the length of off-gauge is reduced by about 36%.
It is demonstrated by using a highly positive uranium ion as a test case that the exact relation between the small and the large components of a Dirac spinor in relativistic self-consistent-field (RSCF) calculations is not fully satisfied by the kinetic balance condition only even for two electron systems. For a fixed number of large component basis functions, total energies are sensitive to the change of the size of the small component basis sets even after the kinetic balance condition is fully satisfied. However, the kinetic balance condition appears to be a reasonable guideline in generating reliable and practical basis sets for most applications of RSCF calculations. With a complete small component basis set, energies from RSCF calculations exhibit a variational behavior, implying the stability of the present RSCF procedure.
Proceedings of the Korea Contents Association Conference
/
2007.11a
/
pp.209-211
/
2007
The computational time of Stocahstic Diagonalization (SD) calculation for 2-dimensional interacting fermion systems is reduced by using several methods including symmetry operations. First, each lattice is subdivided into spin-up and spin-down lattices separately, thus allowing a bi-partite lattice. A valid basis state is then obtained from stacking up an up-spin configuration on top of a down-spin configuration. As a consequence, the memory space to be used in saving the trial basis state reduces significantly. Secondly, the matrix elements of a Hamiltonianin are reconrded in a look-up table when making basis state set. Thus the repeated calculation of the matrix elements of the Hamiltonian are avoided during SD process. Thirdly, by applying symmetry operations to the basis state set the original basis state is transformed to a new basis state whose elements are the eigenvectors of the symmetry operations. The ground state wavefunction is constructed from the elements of symmetric - bonding state - basis state set. As a result, the total number of basis states involved in SD calculation is reduced upto 50 percentage by using symmetry operations.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.