• Title/Summary/Keyword: Basic good

Search Result 2,306, Processing Time 0.027 seconds

A Comparison Study of the Bulbous Bow Shape for LPG Carrier (LPG 선박의 선수 Bulb 형상 비교 Study)

  • Lee Jongki;Park Jaesang;Kim Sungpyo
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.31-37
    • /
    • 2005
  • An attempt to improve the speed performance through the minimizing in wave resistance has been done by an application of gooseneck and no bulb type to bulbous bow for the DSME 78,500 Class LPG Carrier on the basis of the CFD calculation and comparatives model tests. The hydrodynamic characteristics according to the variation of the shape of Cp-curve, design load water line, frame line and bulbous bow that have an important effect on the wave resistance has been evaluated/calculated by ship-flow code. A wide variety in hull variation have been tried to have a good hull form with three types of fore-body hull forms mainly classified by the shape of bulbous bow. The speed performances for the three final hull forms with different bulbous bows have been evaluated through the model tests.

  • PDF

Determination of Ag(Ⅰ) Ion at a Modified Carbon Paste Electrode Containing N,N'-Diphenyl Oxamide

  • Won, Mi-Sook;Yeom, Jeong-Sik;Yoon, Jang-Hee;Jeong, Euh-Duck;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.7
    • /
    • pp.948-952
    • /
    • 2003
  • New approach for the determination of Ag(I) ion was performed by using a carbon paste electrode (CPE) containing N,N'-Diphenyl oxamide (DPO) with anodic stripping voltammetry. The CMEs have been prepared by making carbon paste mixtures containing an appropriate amount of DPO salt coated onto graphite particles to analyze trace metal ions via complexation followed by stripping voltammetry. Various experimental parameters affecting the response, such as pH, deposition time, temperature, and electrode composition, were carefully optimized. Using differential pulse anodic stripping voltammetry, the logarithmic linear response range for the Ag(I) ion was 1.0 × $10^{-7}$ - 5.0 × $10^{-9}$ M at the deposition time of 10 min, with the detection limit was 7.0 × $10^{-10}$ M. The detection limit adopted from anodic stripping differential pulse voltammetry was 7.0 × $10^{-10}$ M for silver and the relative standard deviation was ± 3.2% at a 5.0 × $10^{-8}$ M of Ag(I) ion (n = 7). The proposed electrode shows a very good selectivity for Ag(I) in a standard solution containing several metals at optimized conditions.

Strained-SiGe Complementary MOSFETs Adopting Different Thicknesses of Silicon Cap Layers for Low Power and High Performance Applications

  • Mheen, Bong-Ki;Song, Young-Joo;Kang, Jin-Young;Hong, Song-Cheol
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.439-445
    • /
    • 2005
  • We introduce a strained-SiGe technology adopting different thicknesses of Si cap layers towards low power and high performance CMOS applications. By simply adopting 3 and 7 nm thick Si-cap layers in n-channel and p-channel MOSFETs, respectively, the transconductances and driving currents of both devices were enhanced by 7 to 37% and 6 to 72%. These improvements seemed responsible for the formation of a lightly doped retrograde high-electron-mobility Si surface channel in nMOSFETs and a compressively strained high-hole-mobility $Si_{0.8}Ge_{0.2}$ buried channel in pMOSFETs. In addition, the nMOSFET exhibited greatly reduced subthreshold swing values (that is, reduced standby power consumption), and the pMOSFET revealed greatly suppressed 1/f noise and gate-leakage levels. Unlike the conventional strained-Si CMOS employing a relatively thick (typically > 2 ${\mu}m$) $Si_xGe_{1-x}$ relaxed buffer layer, the strained-SiGe CMOS with a very thin (20 nm) $Si_{0.8}Ge_{0.2}$ layer in this study showed a negligible self-heating problem. Consequently, the proposed strained-SiGe CMOS design structure should be a good candidate for low power and high performance digital/analog applications.

  • PDF

Blue OLEDs Utilizing Spiro[fluorene 7,9'-benzofluorene]-type Compounds as Hosts and Dopants

  • Kim, Joo-Han;Jeon, Young-Min;Jang, Ji-Geun;Ryu, Sang-Ouk;Chang, Ho-Jung;Lee, Chil-Won;Kim, Joon-Woo;Gong, Myoung-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.3
    • /
    • pp.647-652
    • /
    • 2009
  • A novel spiro-type host material, 5-[4-(1-naphthyl)phenyl]-spiro[fluorene-7,9'-benzofluorene] (BH-1PN) and three new dopants, namely, 5-[diphenylamino)phenyl]-spiro[fluorene-7,9'-benzofluorene] (BH-1TPA), 5-[4-(N-phenyl (m-tolyl)amino]-spiro[fluorene-7,9'-benzofluorene] (BH-1MDPA) and 5-[(N-phenyl)-2-naphthyl]amino-spiro[fluorene- 7,9'-benzofluorene] (BH-1NPA) were designed and successfully prepared using the Suzuki or amination reactions. The electroluminescence characteristics of BH-1PN as a blue host material doped with each of the blue dopants were evaluated. The structure of the device is ITO/DNTPD/NPB/BH-1PN:5% dopant/Alq3/Al-LiF. The device obtained from BH-1PN doped with diphenyl-[4-(2-[1,1;4,1]terphenyl-4-yl-vinyl)phenyl]-amine (BD-1) showed good color purity, efficiency, luminance, and current-density characteristics.

Integrated Microdisk Gold Electrode Modified with Metal-porphyrin and Metal-phthalocyanines for Nitric Oxide Determination in Biological Media

  • Kim, Il-Kwang;Bae, Hyun-Ok;Oh, Gi-Soo;Chung, Hun-Taeg;Kim, Young-Jin;Chun, Hyun-Ja
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.11
    • /
    • pp.1579-1584
    • /
    • 2003
  • An integrated gold microdisk electrode was constructed and modified with metal-porphyrin or metal-phthalocyanines for NO determination in biological media. Microanalysis of NO using square wave anodic stripping voltammetry in $1\;{\times}\;10^{-2}$ M $HClO_4$ was optimal when the accumulation potential was 0.1 V, frequency 100 Hz, and the scan rate was 200 mV/s. When the electrode was modified with metal-porphyrin or metal-phthalocyanines, the anodic peak currents of NO increased due to the catalytic oxidation of NO. In case of Fe(II)-phthalocyanine modified electrode, the peak currents remarkably increased and the sensitivity was high. The calibration curve had good linearity in the range from $3.6\;{\times}\;10^{-5}$ M to $7.2\;{\times}\;10^{-7}$ M, and the detection limit was $5.7\;{\times}\;10^{-7}$ M. For the structural stability and increased sensitivity, Fe(II)-phthalocyanine modified gold microdisk electrode coated with Nafion was applied to determination of NO released from cultured macrophase.

Education Method for Basic Programming Subject through Physical Computing (피지컬 컴퓨팅을 통한 기초 프로그래밍 교육 방법)

  • Hur, Kyeong;Sohn, Won-Sung
    • Journal of Practical Engineering Education
    • /
    • v.9 no.2
    • /
    • pp.139-148
    • /
    • 2017
  • As the connection between objects and computers becomes easier, learning using physical computing is presented as a good alternative to solve the problems raised in programming education for beginners. In this paper, we propose a training method that can be applied to basic programming courses for beginners. To do this, we will proceed with a basic programming lecture based on the physical computing method. Currently, physical computing courses focus on various input sensor connection methods and output device control. However, the content of programming education using physical computing materials is lacking. In this paper, we proposed and tested a teaching method that is used in programming education by using low cost materials used in physical computing.

A Structural Model of Health Behavior Compliance in Patients with Percutaneous Coronary Intervention based on Self-Determination Theory (자기결정성이론 기반 관상동맥중재술 환자의 건강행위 이행 구조모형)

  • Park, Ae Ran
    • Journal of East-West Nursing Research
    • /
    • v.24 no.2
    • /
    • pp.101-109
    • /
    • 2018
  • Purpose: The purpose of this study was to construct and test a structural equation model of health behavior compliance among patients with percutaneous coronary intervention based on self-determination theory. Methods: A total of 227 participants who received follow-up care after percutaneous coronary intervention were recruited. A structured questionnaire was used to assess health providers' autonomous support, basic psychological needs, autonomous motivation, controlled motivation, type D personality, and health behavior compliance. Collected data were analyzed using SPSS 21.0 and AMOS 21.0 program. Results: The final hypothetical model showed a good fitness with data: GFI=.94, RMSEA=.07, CFI=.96, NFI=.92, TLI=.94. The results revealed that autonomous support of health care providers, basic psychological needs, and autonomous motivation, and D-type personality accounted for 51.8% of health behavior compliance. Conclusion: The findings of this study indicate that enhanced autonomous support of health care providers is essential to promote patients' basic psychological needs and autonomous motivation. This leads to maximized compliance to the health behaviors among patients who underwent percutaneous coronary intervention. We recommend that health care institutions establish various measures to foster the special environments in which health care providers can actively provide and utilize autonomous support for their patients.

Partitioning effects and corrosion characteristics of oxyapatite glass-ceramic wasteforms sequestering rare-earth elements

  • Kim, Miae;Kang, Jaehyuk;Yoon, Jang-Hee;Lee, Sang-Geul;Um, Wooyong;Kim, Hyun Gyu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.997-1002
    • /
    • 2022
  • Oxyapatite[Ca2Nd8(SiO4)6O2] glass-ceramics have been suggested as wasteforms for the immobilisation of rare-earth radioactive nuclides because of their high waste-loading capability and good chemical durability. In particular, a partitioning effect is predicted to contribute to an enhancement of corrosion resistance in glass-ceramics compared with that of conjugate glasses of the same composition. Because rare-earths are inherently insoluble nuclides, detection of changes in corrosion behavior between glass-ceramics and conjugate glasses under normal conditions is not easy. In this study, therefore, we revealed the partitioning effect by exposing glass-ceramics and glasses to solution of pH 2, 7 and 10 at 90 ℃ for 20 d. In addition, we proposed the corrosion mechanism for oxyapatite glass-ceramics under various corrosion conditions. Especially, the glassy phase dissolved first, followed by the oxyapatite phase during pH 7 corrosion.

Jigsaw class participation experience

  • Jungae Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.1
    • /
    • pp.227-233
    • /
    • 2024
  • This study was conducted to understand the essential structure and meaning of the experience of participating in the Jigsaw class designed to achieve the learning goals for nursing students with different basic learning abilities, and to prepare a plan for each individual to learn as a collaborator rather than a competition with each other. As a study based on Giorgi's phenomenological research method and in-depth interviews, data collection was collected from 10 study participants from December 1, 2023 to December 20, 2023. The main question used in the interview was "What impressed you after participating in Jigsaw teaching meathod?" The transcribed data were analyzed through the stages of overall recognition, classification of semantic units, transformation of semantic units into psychological expressions, and integration into general structures according to Giorgi's qualitative analysis method. As a result, a total of 89 semantic units, 35 essential psychological meanings, 13 sub-components, and 6 components were derived. The six components include 'good communication', 'difference appear in material preparation', 'easy to understand', 'finding team members who form a learning atmosphere well', 'A talkative class', and 'Unprepared team members are uncomfortable'. Based on the above results, it is expected that students in a passive position in class will become teachers themselves, take responsibility for preparing for learning, and provide useful basic data for developing programs that cooperate among students.

Antimicrobial Activity and Physical Properties of Acrylic Acid Grafted Nylon 6 (아크릴산 그라프트 Nylon 6의 항균성 및 물성)

  • 김수미;송화순
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.5
    • /
    • pp.686-695
    • /
    • 2000
  • Recently, with a growing interest of health and environment, chitosan which was good in no harmful effect to human body and environment, has been watched as the finish treatment of hygiene and pleasantness. The purpose of this study is to develop multifunctional fabric that was improved antimicrobial activity and deodorization rate, water absorption, static voltage and dye absorption by treatment of nylon 6 grafted with acrylic acid added in chitosan. FT-IR spectra of the grafted with acrylic acid added in chitosan shows peaks of COOH and NH2. Antimicrobial activity and deodorization rate of chitosan and grafted with acrylic acid added in chitosan were increased greatly than the control, durability of laundry of grafted with acrylic acid added in chitosan was good. In case of chitosan was dyed acid dyes and grafted with acrylic acid added in chitosan was dyed basic dyes, dye absorption of them were increased than the control. Moisture regain, absorption time and tensile strength of grafted with acrylic acid added in chitosan was increased greatly than the control.

  • PDF