• 제목/요약/키워드: Base plate

검색결과 614건 처리시간 0.022초

트렁크 래치의 베이스 플레이트와 접촉스위치의 최적화 (Optimization of Base Plates and Contact Switches in Trunk Latches)

  • 김경남;노유정;김동훈
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.97-104
    • /
    • 2014
  • Automobile trunk latches enable trunks to be opened and closed by a latch mechanism, which can be selectively positioned between a locked condition and an open condition. To maintain structural and electronic performance of the trunk latch, the latch needs to endure impact load that occurs in its open and close motion, and a dynamic mechanism needs to be electronically controled by a contact switch connected with a small DC motor. A base plate, which is the most important component relating to the structural safety, commonly uses a high stiffness material SAPH440-P with high manufacturing cost. In this paper, through structural analysis and optimization, production cost is significantly reduced by replacing SAPH440-P used in some region of the base plate with engineering plastic PBT GF 20%. The optimized contact switch reduces difference between distributed pressures of its two legs, which leads to improve the electronic performance of the trunk latch.

면진장치를 사용한 주거용 무량판구조의 내진성능 향상 (Seismic Performance Enhancement of Residential Flat Plate Structure by Using Base Isolation Devices.)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권3호
    • /
    • pp.185-191
    • /
    • 2007
  • 본 연구에서는 주거용 무량판구조의 내진성능을 개선하기 위한 면진적용 가능성을 평가하였으며, 시간이력 해석을 위한 지진기록 사용에 대한 문제점을 제시하였다. 면진층 강성 및 주기 평가 및 포락해석법을 적용하여 면진전 비틀림 모드가 강한 구조물을 면진시스템 적용으로 내진성능을 개선하였다. 지진기록 사용 및 크기 조절효과의 적정성을 평가하기 위하여 DBE, MCE, ASCE 7-05의 1.4DBE 의해 크기를 조정한 시간이력 해석결과를 비교한 결과, 구조물의 지반조건과 유사한 조건에서 관측된 지진기록 및 지진기록의 응답이 설계규준 응답스펙트럼의 평균${\pm}$표준편차 범위 안에 있는 기록을 사용하는 것이 적절한 것으로 판단된다.

4개 대칭배열 발열 전자소자에서의 확산 열저항 산정 (Evaluation of Spreading Thermal Resistance in Symmetrical Four-Heat Generating Electronic Components)

  • 김윤호;김서영;리광훈
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.664-671
    • /
    • 2006
  • We propose the correlation to predict the spreading thermal resistance on a plate with symmetrical four heat sources. The correlation transforms four heat sources to a single equivalent heat source and then the spreading thermal resistance can be obtained with the existing equation for a single heat source. When the four heat sources are mounted on a square base plate, the correlation is expressed as a function of the heat source size, the length of base plate, the plate thermal conductivity and the distance between heat sources. Compared to the results of three-dimensional numerical analysis, the spreading thermal resistance by the proposed correlation is in good agreement within 10 percent accuracy.

연화부를 포함한 판재의 항복거동과 항복강도 (Yielding behavior and yield strength of plate structure containing softened region)

  • 배강열;김희진;이태열;엄동석
    • Journal of Welding and Joining
    • /
    • 제8권3호
    • /
    • pp.79-88
    • /
    • 1990
  • Welded joint often contains soft or softened regions such as the HAZ of TMCP steel welded with high heat input. In this study, the equivalent yield strength of plate structure containing softened region was predicted by FEM analysis, and its incremental behavior was explained with the results of the analysis. The calculated results of yield strength indicated the following for the plate structures. 1) As the softened region starts to yield, shear stress begins to build up along the boundary between base metal and softened region. This results in multi-axial stress condition which gives restraint on the softened region. 2) Restraint effect has a significant influence on the distribution of the shear stress, the nominal stress, and the strain. 3) The yielding behavior of softened region becomes the same as that of base metal when both ratios of length to width and thickness to width of softened region are larger than 30 and 13 respectively.

  • PDF

매립지반의 팽이말뚝 평판재하시험 사례 연구 (Case Study Top-Base Foundation Static Loading Test in Reclaimed Land)

  • 신은철;김성환;이애영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.721-728
    • /
    • 2008
  • Top-Base Method is a stabilization method for light weight structures particularly in the soft ground. It is widely used for the increment of bearing capacity and the effect of restraining settlement when the bearing capacity of the ground is not enough. Top-shaped cone concrete foundations are installed in graveled laid over soft ground. The principle of the basic method is to maximize effect of dispersing the overburden pressure by increasing the contact area of the top-shaped cone. Therefore, the bearing capacity is increased and the settlement is decreased by the embedded resistance of pile part in the ground. In this paper, the plate bearing test was conducted to evaluate the feasibility of Top-Base foundation. Based on the test results, the coefficient of subgrade reaction, elastic modulus, and settlement of foundation on reclaimed land was derived.

  • PDF

부양형 팽이기초의 하중전달 메커니즘에 따른 거동 (Behavior of Floating Base Plate by Stress Delivery Mechanism)

  • 정진혁;정효권;이송
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.137-144
    • /
    • 2010
  • 팽이기초에 대한 일본과 국내에서 현재까지 공통적으로 연구되고 있는 것은 팽이기초의 현장재하실험에 대한 지지력과 침하량에 주목되어 있다. 그러나 팽이기초에서 선행되어야할 연구는 공법 자체가 상재하중을 하부에 어떠한 원리로 전달되는 지에 대한 분석이 수행되어야 한다. 이에 본 연구에서는 일본에서 개발된 Top-Base Foundation과 국내에서 개발된 부양형 팽이기초의 응력전달 메커니즘을 수치해석 및 실내모형실험을 통하여 분석하였다. 팽이기초의 하중전달 메커니즘을 분석한 결과 상재하중에 대한 팽이기초 자체의 하중저감 분담률은 주로 팽이기초와 쇄석사이에서 발생하는 주면마찰력이 가장 크게 나타났다. 또한, 팽이기초의 내부응력분산효과를 포함한 Top-Base Foundation의 총 응력분산각은 $41.8^{\circ}$이며, 부양형 팽이기초의 총 응력분산각은 $44.5^{\circ}$로 산정되었다.

Salmonella System에 있어서의 농약의 돌연변이 유발성 (Mutagenicity of Pesticides in the Salmonella System)

  • 백형석;변우현;전문진;이세영
    • 한국미생물·생명공학회지
    • /
    • 제5권4호
    • /
    • pp.159-165
    • /
    • 1977
  • Salmonella typhimurium LT-2의 histididine auxotroph 중 base substitute mutant인 TA 1535와 TA100, 그리고 frame-shiftmutant인 TA 1538과 TA 98을 각각 사용하였고 microsomal enayme activation system을 병용하여 국내 사용농약 20종에 대한 돌연변이 유발성을 검하였다. 이중 다음 4종의 농약이 양성 및 의양성의 유발성을 나타냈다. (1) Captan은 강력한 돌연변이 유발성질로서 TA1535, TA100 및 TA98에 대해 직접적으로 10$\mu\textrm{g}$/plate의 농도에서 plate당 각각 205, 1012, 그리고 297의 돌연변이 균종의 출현을 나타냈으며 microsomal enzyme activation에 의해 그 유발능력이 약간 감소되는 경향을 보였다. (2) Micut는 TA100에 대해 직접적으로 10mg/plate의 농도에서 55 revertant 정도의 미비한 돌연변이 유발성을 나타냈다. (3) Dimethoate는 TA100에서 역시 직접성으로 처리가능 최고농도인 0.2λ/plate에서 55 revertant/plate 정도의 징약한 돌연변이 유발성을 바타냈다. (4) Triforing도 역시 TA 100에서 직접적으로 10mg/plate로 처리된 농도에서 78 revertant/plate정도의 약한 돌연변이 유발성을 나타했다.

  • PDF

현장평판재하시험에 의한 현장타설형 팽이말뚝기초의 지지력산정 (Estimation of Bearing Capacity for In-Situ Top-Base Method by Field Experimental Plate Load Test)

  • 신은철;안민희
    • 한국지반신소재학회논문집
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2011
  • 연약지반상에 구조물을 축조하게 되면 지반의 지지력 부족, 과대침하량 및 측방변형과 같은 문제점이 발생한다. 팽이말뚝기초공법은 지지력이 다소 부족한 지반에 팽이형 콘크리트 파일을 연약지반기초에 사용하여 지지력 증가와 침하억제, 부등침하방지 등의 효과를 도모하는 연약지반 표면 처리용 강성매트공법이며, 공사비 절감 등의 경제적인 효과와 공사기간 단축, 공사 중 소음 등으로 인한 민원 차단 등의 시공에 따른 편의성을 확보할 수 있다. 따라서 본 연구에서는 현장평판재하시험을 통하여 연약지반상의 현장타설형 팽이말뚝기초의 지지력을 산출하였다. 평판재하시험 분석결과를 통해 기존 연구 및 설계에서 적용하고 있는 제안식과 비교분석하여 현장타설형 팽이말뚝기초를 기초지반에 적용할 시 기초의 합리적인 범위를 산정하여 향후의 설계에 그 결과를 활용하고자 한다.

Base Isolator의 제작 및 특성실험

  • 김남식;유춘화;이동근
    • 전산구조공학
    • /
    • 제5권4호
    • /
    • pp.41-45
    • /
    • 1992
  • 본 실험에서는 가장 널리 쓰이는 base isolator의 한 종류로서 laminated rubber bearing을 제작하여 정적 및 동적 특성실험을 수행하였다. 앞에서 간략하게 언급한 실험결과에 대한 분석자료는 상부구조물과 기초와의 분리를 목적으로 본 실험에서 제작한 base isolator의 활용가능성을 검증하였다. 일반적으로 base isolator가 갖는 특성을 대부분 포함하고 있지만 본 실험결과에서 얻은 개선점은 i) 수직강성의 보강 ii) mounting plate와의 볼트연결부분 보완 iii) 최대전단변형을 증가시키기 위해 base isolator의 전체높이 조정 등으로 요약할 수 있다.

  • PDF

소규모 철골조건축물을 위한 약축방향 노출형 주각부의 내진성능 향상 (Seismic Performance Enhancement of Exposed Column-base Plate Weak-axis Connections for Small-Sized Steel Buildings)

  • 유영찬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.1-12
    • /
    • 2019
  • 소규모 철골조건축물의 접합상세에 대한 현장조사에 따르면 지진하중에 의한 횡적 안전성 및 안정성 확보가 불충분할 것으로 예상되는 임의 접합상세가 현장에서 적용되는 것으로 조사되었다. 이에 따라 본 연구에서는 소규모 강구조건축물의 노출형 주각부 약축 연결부의 반복이력 실험을 통해 문제점을 분석하고, 이를 바탕으로 내진성능을 향상시킬 수 있는 접합상세의 개발을 위해 일련의 실험연구를 수행하였다. 본 실험결과에 의하면, 국내에서 흔히 사용되는 노출형 주각부 약축방향 접합부의 이력거동은 앵커볼트가 콘크리트로부터 점진적으로 인발됨에 따라 베이스플레이트와 앵커볼트사이에 이격거리가 누적되어 하중역전구간에서 "Rocking" 현상이 발생되어 내진성능이 매우 낮은 것으로 조사되었다. 이와 같은 문제점을 개선하기 위하하여 앵커볼트의 콘크리트에 대한 부착 유/무와 개수 및 배열형태 등을 변수로 한 성능개선 실험체에 대한 일련의 반복 이력 실험을 수행하였으며, 최종적으로 소규모철골조 건축물의 노출형 주각부에 고강도 전산볼트형 앵커볼트를 8개로 3열로 배치하는 상세의 적용을 통하여 하중지지능력과 에너지분산능력 측면에서 내진성능이 크게 개선된 것을 확인할 수 있었다.