• Title/Summary/Keyword: Base Capacity

Search Result 982, Processing Time 0.025 seconds

Load-Settlement Characteristics of Concrete TOP-BASE Foundation on Soft Ground (팽이기초공법(Top-Base Method)의 하중-침하량 분석)

  • Kim, Jae-Young;Jeong, Sang-Seom;Lee, Jae-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.210-221
    • /
    • 2009
  • A new foundation type which is called Top-Base method has been used frequently in engineering practices in Korea. In this study, the settlement behavior of concrete Top-Base foundation on soft ground is investigated since the consolidation settlement of the embedding depth and the effect of footing dimensions are not included in current Korean criterion (2007). To obtain detailed information, the model tests of the Top-Base foundation are performed using the PLAXIS 3D finite element analysis. It is shown that in-situ measurements and finite element analysis of the behavior of foundations indicate that consolidation settlement is reduced up and bearing capacity of the foundation increases up to 50%~100%, compared to the primary non-treated ground. Based on this study, it is found that the Top-Base foundation prevents the lateral deformation of soft ground and reduces its negative dilatancy to the surface settlement, and that the foundation creates rather uniform stress distribution under it to increase its bearing capacity. It is also found that the total settlement of Top-Base foundation was highly dependent on the consolidation settlement and footing configurations.

  • PDF

Modeling of Acid/Base Buffer Capacity of soils (토양의 산/염기 완충능의 모델링)

  • 김건하
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.3-10
    • /
    • 1998
  • Acid/Base buffer capacity of soil is very important in prediction of contaminant transport for its direct impact on pH change of the system composed of soil-contaminant-water, In this research, diffuse double layer theory as well as two layer electrostatic adsorption model are applied to develop a theoretical model of buffer capacity of soil. Model application procedures are presented as well. Buffer capacity of Georgia kaolinite and Milwhite kaolinite was measured by acid-base titration. Model prediction and experimental results are compared.

  • PDF

Bearing capacity of foundation on rock mass depending on footing shape and interface roughness

  • Alencar, Ana S.;Galindo, Ruben A.;Melentijevic, Svetlana
    • Geomechanics and Engineering
    • /
    • v.18 no.4
    • /
    • pp.391-406
    • /
    • 2019
  • The aim of this paper was to study the influence of the footing shape and the effect of the roughness of the foundation base on the bearing capacity of shallow foundations on rock masses. For this purpose the finite difference method was used to analyze the bearing capacity of various types and states of rock masses under the assumption of Hoek-Brown failure criterion, for both plane strain and axisymmetric model, and considering smooth and rough interface. The results were analyzed based on a sensitivity study of four varying parameters: foundation width, rock material constant (mo), uniaxial compressive strength and geological strength index. Knowing how each parameter influences the bearing capacity depending on the footing shape (circular vs strip footing) and the footing base interface roughness (smooth vs rough), two correlation factors were developed to estimate the percentage increase of the ultimate bearing capacity as a function of the footing shape and the roughness of the footing base interface.

Evaluation of the Installation Mechanism of the Micropile with the Base Expansion Structure Using a Centrifuge Model Test (원심모형실험을 활용한 선단확장형 마이크로파일의 설치 메커니즘 평가)

  • Kim, Jae-Hyun;Kim, Seok-Jung;Han, Jin-Tae;Lee, Seokhyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.11
    • /
    • pp.37-49
    • /
    • 2021
  • Micropiles are widely used in construction field to enhance bearing capacity and reduce settlement of existing foundation. It has various benefits such as low construction expense, simple installation process, and small construction equipment. Recently, new microple equipped with the base expansion structure at the end has been developed to improve the foundation bearing capacity. The improvement of load capacity can be conceptually achieved by expanding the base expansion structure when a load is applied to the micropile. However, the expansion mechanism of the base expansion structure and the improvement of load capacity of the micropile were not yet experimentally validated. Therefore, in this study, a series of centrifuge model tests was performed to evaluate the effect of the base expansion structure on the improvement of load capacity. Two types of soil, sand and weathered rock, were prepared and the loading tests were performed using the real micropile with the base expansion structure. During the tests, the earth pressures surrounding the base expansion structure were monitored. As a result, when a load of 30 kN was applied to the micropile, the increase in the ratio of the horizontal to vertical pressure increment (∆σh/∆σ𝜈) ranged from 0.4 to 0.58 in sand and ∆σh/∆σ𝜈 = 0.19 in weathered rock, respectively. Therefore, it can be concluded that the increase in the horizontal earth pressure adjacent to the base expansion structure will improve the bearing capacity of the micropile.

Capacity Analysis of Base Stations in CDMA Mobile Communications Systems in the Subway Environment (지하철 환경에서 CDMA 이동통신시스템의 기지국 용량 분석)

  • Yang, Won-Seok;Yang, Eun-Saem;Park, Hyun-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.7B
    • /
    • pp.789-794
    • /
    • 2011
  • We analyze the capacity of CDMA base stations in the subway environment. We investigate the characteristics of multipath fading, cell structures, and propagation environment in the subway, analyze signal to noise ratio, sectorization gain, path-loss exponent, frequency reuse factor, and obtain the link capacity of a base station in the subway. We measure the peakedness factor and reveal that base stations in the subway have peaked traffic. We use Neal-Wilkinson model to obtain the Erlang capacity instead of Erlang-B model based on Poisson traffic.

Model Test on the Effect of Bearing Capacity for In-situ Top Base Method in sand (현장타설 팽이말뚝기초공법의 지지력 증대효과에 관한 모형실험 연구)

  • Kang, Hong-Kyu;Kim, Chan-Kuk;Lee, Bong-Yul;Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.597-602
    • /
    • 2005
  • The present precast top-base method create many problems of requiring it plant facilities, transportation and installation, due to the heavy weight of and it takes too long time to set it up on site. In order to improve and solve these problems, in-situ Top-Base method is developed. It include processes that install Top-Base mold made of poly-ethylene into ground, then pouring concrete into the mold, and fill the rest gaps with broken stones. Considerable advantages can be obtained by applying in-situ Top-Base method in aspects of the stability, economical and construction efficiency. In this research, model tests for in-situ Top-Base system are carried out in other to the investigate the load delivering mechanism and the effect of bearing capacity.

  • PDF

Estimation of Bearing Capacity for In-Situ Top-Base Method by Field Experimental Plate Load Test (현장평판재하시험에 의한 현장타설형 팽이말뚝기초의 지지력산정)

  • Shin, Eun-Chul;Ahn, Min-Hye
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • The problems like a deterioration of loading bearing capacity, an exaggeration of settlement and lateral deformation are able to be generated, meanwhile structures are built in soft ground. Top-Base method is belonged to a rigidity mat foundation method which is used to surface treatment of soft ground. This method makes an effect to increase the bearing capacity of foundation using friction force, and prevent the differential settlement. Further more, the In-Situ Top-Base method has advantages in the phase of economic effect by reduction of the construction cost and offers an expediency on construction comparing with precast products. This paper presents the way of the estimation of bearing capacity for In-Situ Top-Base method through field plate load test in soft ground. It utilizes the results to a future design by analyzing the properties in the existing study and designs through these analysis and calculating the top-base method's reasonable range.

Bearing Capacity Reinforcing Effect of Forest Road Surface by Construction of Sub-base using Geosynthetics (토목섬유 활용 노반 조성을 통한 임도 노면지지력 강화효과 분석)

  • Hwang, Jin-Seong;Ji, Byoung-Yun;Lee, Kwan-Hee;Kweon, Hyeong-Keun;Kim, Myung-Hwan
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.2
    • /
    • pp.166-173
    • /
    • 2018
  • This study was carried out to establish the standard of sub-base facility which can strengthen road surface bearing capacity for smooth passage of logging trucks in forest road as the size of the logging truck has been increased in order to improve the efficiency of timber transportation. The results of reinforcement effect analysis of the surface bearing capacity by the thickness of sub-base prepared with the optimum aggregate mix ratio using geosynthetics for forest road on the soft ground in the Forest Technology and Management Research Center are as follows. The surface bearing capacity of CBR exceeding 15% was found to be sufficient when the sub-base was constructed over 0.2 m depth of laying gravels with installation of geosynthetics after digging out subsoil. However, there is no significant difference in reinforcement effect of surface bearing capacity by types of geosynthetics. And, it was found that the surface bearing capacity was insufficient in the installation of sub-base. Therefore, in the case of soft ground, It is possible to secure the reinforcement of the surface bearing capacity for the smooth passage of heavy logging trucks by sub-base, that was constructed over 0.2 m depth of laying gravels with installation of geosynthetics after digging out subsoil.

A Study on the Amendment of Base Load Market and CP in Electricity Market (전력시장에서 용량요금 메커니즘 변화의 영향과 개선)

  • Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.255-257
    • /
    • 2007
  • Korea electricity market consists of two payment systems, capacity and energy. Capacity payments are given to the generators according to its hourly availability considering hourly and seasonal weighting factors. Energy payments are settled at the marginal generation cost based on generator variable cost. In 2007, base load energy market is closed and single capacity payment system is begun to apply in electricity market. In this revised market rule, energy price cap for base load generators is newly introduced. We analyze impact of market rule revision in 2007 on base load generators and suggest improvement scheme to enforce market system in this study.

  • PDF

Development of Steel Pipe Attached PHC Piles for Increasing Base Load Capacity of Bored Pre-cast Piles (매입말뚝의 선단지지력 증대를 위한 강관 부착 PHC파일 개발)

  • Paik, Kyu-Ho;Yang, Hee-Jeong
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.53-63
    • /
    • 2013
  • Bored pre-cast piles using PHC piles is widely used in foundation of building structures constructed in urban areas because noise and vibration due to pile installation are low. However, since slime is formed at the base of borehole and the density of bearing stratum surrounding the base of borehole is decreased due to stress relaxation in drilling process of bored pre-cast pile method, the base load capacity of bored pre-cast piles is very low compared to the strength of bearing stratum. In this study, a new type of PHC pile, which short steel pipe with the same diameter as the PHC pile is attached to the pile tip, is developed to increase the base load capacity of bored pre-cast piles. In order to check the effect of the use of new PHC pile on the base load capacity of bored pre-cast piles, field pile load tests are performed for bored pre-cast piles using the new and existing PHC piles. Results of the pile load tests show that the new PHC pile gives higher base load capacity to bored pre-cast piles than the existing PHC pile, since the tip of new PHC pile is penetrated to undisturbed bearing stratum passing through the slime at the base of borehole and the loosened bearing stratum under the slime by pile driving using light hammer.