Load-Settlement Characteristics of Concrete TOP-BASE Foundation on Soft Ground

팽이기초공법(Top-Base Method)의 하중-침하량 분석

  • 김재영 (연세대학교 공과대학 토목공학과) ;
  • 정상섬 (연세대학교 공과대학 토목공학과) ;
  • 이재환 (연세대학교 공과대학 토목공학과)
  • Published : 2009.03.27

Abstract

A new foundation type which is called Top-Base method has been used frequently in engineering practices in Korea. In this study, the settlement behavior of concrete Top-Base foundation on soft ground is investigated since the consolidation settlement of the embedding depth and the effect of footing dimensions are not included in current Korean criterion (2007). To obtain detailed information, the model tests of the Top-Base foundation are performed using the PLAXIS 3D finite element analysis. It is shown that in-situ measurements and finite element analysis of the behavior of foundations indicate that consolidation settlement is reduced up and bearing capacity of the foundation increases up to 50%~100%, compared to the primary non-treated ground. Based on this study, it is found that the Top-Base foundation prevents the lateral deformation of soft ground and reduces its negative dilatancy to the surface settlement, and that the foundation creates rather uniform stress distribution under it to increase its bearing capacity. It is also found that the total settlement of Top-Base foundation was highly dependent on the consolidation settlement and footing configurations.

Keywords