The Academic Congress of Korean Shoulder and Elbow Society
/
2008.03a
/
pp.178-178
/
2008
In order to improve static stability and healing of reattached labrum, we combined the advantages of suture bridge and transosseous technique. Using the conventional 3 portal for anterior instability, check stability of bony Bankart and preparation of glenoid bed in 3 way including removal, reshaping or mobilization of bony fragment. Two anchors were inserted to the superior and inferior portion and medial edge of bony Bankart lesion. It usually corresponded to the area of IGHL. Medial mattress sutures were applied around IGHL complex to get enough depth of glenoid coverage using suture hook. Make 3.5mm pushlock anchor hole to the articular edge of glenoid cartilage. Proximal suture bridge was applied at first and then distal suture bridge was inserted to mobilize the labrum in proximal direction. These construction can provide more stable labral repair with wide contact and compression in case of deficient bony stability. It not only avoids technical disadvantage of point contact with anchor fixation, but also decreasing gap formation through cross compression of labrum that couldn't gain even with the transosseous fixation which affords linear compression effect. Additional bony stability could be gained if the the bony fragment was mobilized to the glenoid margin with potential healing bed or reshaped for the good contact with reattached labrum.
Background: The blunted tip of a reusable with multiple uses can cause problems with the passing procedure in arthroscopic Bankart repair. This study assessed the advantage of Scorpion with a $70^{\circ}$ arthroscope in arthroscopic Bankart repair compared to hook typed suture passer. Methods: Scorpion in 19 patients, the hook type suture passer (conventional group) in 18 patients were used. All patients underwent the same procedure except for the type of suture passer used. Another different point of the procedure were telescopes and the number of portals used; three arthroscopic portals (posterior, anterorsuperiorlateral, and mid-anterior) and a $30^{\circ}$ arthroscope in the conventional group, but two portals and a $70^{\circ}$ arthroscope as well as the $30^{\circ}$ one in the Scorpion group. The surgery time and the surgical complications including an iatrogenic axillary nerve injury were recorded. Results: The Scorpion group showed a significant decrease in surgery time compared to the conventional group. In contrast to the conventional group, Scorpion provided an easy estimation of the exit of suture passing, no iatrogenic labral injury during the passing procedure with straight movement and the sharp tip of the knife installed. Iatrogenic supraspinatus injuries could be avoided when making an accessory anteosuperiorlateral portal due to the $70^{\circ}$ arthroscope. Conclusions: In arthroscopic Bankart repair, the use of the Scorpion suture passer and a $70^{\circ}$ arthroscope can reduce the surgery time, avoid unnecessary supraspinatus injury, and avoid iatrogenic axillary nerve damage through the relatively easy and precise suture passing and saving of the anterosuperior portal.
Purpose: To Analyze the exit site of pin inserted at the anterior glenoid rim in the reconstruction of the Bankart lesion and SLAP lesion using transglenoid suture technique. Materials and Methods: In the twenty adult right cadeveric scapula, insertions of pin were performed using guide at the position of 1, 2, 3 O'clock of glenoid rim. We measured the exit site of dorsal surface of the scapula by medial distance from sagittal plane of lateral border of scapular spine and the vertical distance from posterior border of the scapular spine. Results: When the pin was inserted caudally within 10 degree, at the position of 1, 2, 3 O'clock, the medial distance from lateral border of the scapula is averaged 29.4, 19.2, 34.0 mm respectively and the vertical distance from posterior border of the scapular spine is averaged 15.0, 18.6, 17.2 mm respectively. When the pin was inserted caudally within 20-30 degree, the medial distance is averaged 14.6, 14.2, 15.8 mm respectively and the vertical distance is averaged 31.6, 31.9, 32.1 mm respectively. Conclusion: When the pin was inserted caudally within ten degrees using the guide, the pin exit appeared at the more medial side of the base of scapular spine and the more inferior of scapular spine. This can make the firm suture tied over scapular spine during repair SLAP and the Bankart lesion, and also prevent the injury of suprascapular nerve.
Background: The purpose of this study is to investigate clinical outcomes and radiological findings of cyst formation in the glenoid around suture anchors after arthroscopic Bankart repair with either biocomposite suture anchor or all-suture anchor in traumatic anterior shoulder instability. We hypothesized that there would be no significant difference in clinical and radiological outcomes between the two suture materials. Methods: This retrospective study reviewed 162 patients (69 in group A, biocomposite anchor; 93 in group B, all-suture anchor) who underwent arthroscopic Bankart repair of traumatic recurrent anterior shoulder instability with less than 20% glenoid defect on preoperative en-face view three-dimensional computed tomography. Patient assignment was not randomized. Results: At final follow-up, the mean subjective shoulder value, Rowe score, and University of California, Los Angeles shoulder score improved significantly in both groups. However, there were no significant differences in functional shoulder scores and recurrence rate (6%, 4/69 in group A; 5%, 5/93 in group B) between the two groups. On follow-up magnetic resonance arthrography/computed tomography arthrography, the incidence of peri-anchor cyst formation was 5.7% (4/69) in group A and 3.2% (3/93) in group B, which was not a significant difference. Conclusions: Considering the low incidence of peri-anchor cyst formation in the glenoid after Bankart repair with one of two anchor systems and the lack of association with recurrence instability, biocomposite and all-suture anchors in Bankart repair yield satisfactory outcomes with no significant difference.
The Academic Congress of Korean Shoulder and Elbow Society
/
2009.03a
/
pp.185-185
/
2009
관절와 및 상완골의 의미 있는 골결손을 동반한 불안정한 견관절에 대해 어떻게 최선의 치료를 할 것인가에 대한 의문은 남아있다. 어떤 저자들은 외회전과 외전을 제한하는 것으로 Hill-Sachs 병변의 진입을 예방하는 일종의 관혈적 관절낭 변위를 통한 제한된 상완와관절 운동을 주장해왔으며, 다른 관혈적 시술들은 극하근건과 관절낭을 Hill-Sachs 병변 내로 관혈적 전이시키는 것으로 기술되어왔다. 최근에는 여러 저자들에 의해 Hill-Sachs 병변의 진입을 치료하는 더 새로운 접근법들이 기술되었으며, Bankart 병변 복원술에 더하여 Hill-Sachs 병변을 채우기 위해 관절경 하 후방 관절낭 고정술과 극하근건 고정술로 이루어진 이른바 'Remplissage'술기가 소개된 바 있어, 이에 저자는 외상성 견관절 불안정성으로 관절경 하 Bankart 병변 복원술 및 관절낭 축화술 시행 후 외상으로 재발된 견관절 불안정성이 발생하여 관절경 하 Bankart 병변 복원술과 함께'Remplissage'술기를 이용한 Hill-Sachs 병변 복원술을 시행한 예를 보고하는 바이다.
Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.
Purpose: This study reported the outcomes following the use of bioabsorbable knotless anchor in patients with anterior instability of shoulder. Methods: We studied fifteen cases with traumatic anterior shoulder instability underwent arthroscopic Bankart repair with bioabsorbable knotless suture anchor between January 2003 and June 2003. Among fifteen patients, fourteen were male and one was female, with a mean patient age of 24 years (range 16-42). The mean follow-up was 14 months (range 12-18 months). We compared with operation time of twenty cases of arthroscopic Bankart repair by the suture anchor technique between January 2002 and October 2002. Results: Neither recurrent dislocation nor subluxation was happened in postoperative follow-up. Mean score for functional evaluation by Rowe et al. was 89.4 and that for patient subjective satisfaction was 87,5. At last follow-up period, average shoulder range of motion for flexion and external rotation was 171$^{\circ}$ and 54$^{\circ}$ respectively. All patients were satisfied except three who had an apprehension at the follow up. During Bankart repair, it took an average of 25.5 minutes for one knot with the use of suture anchor technique whereas an average of 16.5 minutes for one knot with the use of bioabsorbable knotless anchor. Significantly, we saved operation time with the use of bioabsorbable knotless anchor (P<0.05).Conclusion: Repairing the Bankart lesion with the use of knotless anchor technique has the advantage of obtaining good capsular tensioning and saving operation time. And it is considered to be very successful in treating shoulder instability without recurrent dislocation or subluxation.
Purpose: We compared the results of arthroscopic Bankart repair using metal and biodegradable anchor fixation. Materials & Methods: We reviewed 26 patients with anterior shoulder instability treated by arthroscopic Bankart repair from October, 2006, to March, 2007, 15 patients with metal anchors and 11 patients with biodegradable anchors. The average age was 27.4 years old (range: 17~55) and mean follow-up was 14 months (range: 12~17 months). Functional outcome was evaluated using the Korean Shoulder Score for Instability (KSSI), Rowe's Bankart Grading scale (RBGS), ASES score, and UCLA scores. Results: In the metal-anchor group, the improvements of mean KSSI, ASES, UCLA score, and RBGS were 20.6, 24.0, 4.0, and 45.5, respectively. In the biodegradable anchor group, improvements of mean KSSI, ASES, UCLA score, and RBGS were 21.0, 23.6, 4.6, and 48.9. The improvements in final outcomes were not significantly different (p>.05). One metal problem and one traumatic redislocation occurred in the metal group. Conclusion: Both techniques produced satisfactory outcomes in the treatment of traumatic anterior instability. The biodegradable anchor group could also avoid problems with metal anchors.
Kim Young-Kyu;Lee Jae-Hoon;Kim Hyun-Min;Lee Choong-Hoon
Clinics in Shoulder and Elbow
/
v.8
no.2
/
pp.148-153
/
2005
Purpose: To assess the usefulness of early stabilization for initial shoulder dislocation which is indicated in some patients by comparing the arthroscopic findings and the outcomes of Bankart repair in the initial and recurrent dislocation. Materials and Methods: The study was performed on 16 cases of initial dislocation and 44 cases of recurrent dislocation. The follow-up period was 25 months in the initial dislocation group and 28 months in the recurrent group. Bankart lesion and the adjacent tissues were compared, and the results were evaluated by the Rowe rating scale. Results: Detached labrum and capsular ligament of the initial dislocation group were elastic and unretracted. While in the recurrent dislocation those were inelastic, and displaced and adhesive in many cases. The outcomes were mean 95 points in the initial group and 91 points in the recurrent group. In the initial group, apprehension was detected in only 1 case(6%). In the recurrent group, instability was detected in 4 cases(9%). Conclusion: Our data suggest that Bankart lesion in the initial dislocation can be repaired readily by surgery, the recovery is efficient, and the recurrence would be reduced. Thus, in active young sports lovers as well as athletes, early stabilization surgery for initial shoulder dislocation may be more helpful.
Purpose: Point fixation at the margin of the glenoid is a limitation of conventional arthroscopic stabilization using suture anchors, and does not afford sufficient footprint healing, especially in glenoid bone deficiency. So, we introduce an arthroscopic suture bridge transosseous-equivalent technique for bony Bankart lesions to avoid the technical disadvantage of point contact with anchor fixation and to improve mechanical stability through cross compression of the labrum. Surgical approach: The technique was adapted from the transosseous-equivalent rotator cuff repair technique using suture bridges, which improved the pressurized contact area and mean pressure between the tendon and footprint. After preparation of the glenoid bed by removal, reshaping, or mobilization of the bony lesion, two anchors (3.0 mm Biofastak, $Arthrex^{(R)}$, Naples, FL) were inserted into the superior and inferior portion of the bony Bankart lesion. Using a suture hook, medial mattress sutures were applied around the capsulolabral portion of the IGHL complex to obtain sufficient depth of glenoid coverage. A 3.5 mm pushloc anchor ($Arthrex^{(R)}$, Naples, FL) hole was made in the articular edge of the anterior glenoid rim. distal, suture bridge was applied, and proximal was inserted to mobilize the labrum in the proximal direction. This avoided the technical disadvantage of point contact with anchor fixation and decreased the level of gap formation through cross-compression of the labrum.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.