DOI QR코드

DOI QR Code

Outcomes after Arthroscopic Repair of Anterior Shoulder Instability after Metal Anchor to Biodegradable Anchor Fixation

견관절 전방 불안정성에 대한 관절경 치료 결과: 금속 나사못 및 흡수성 나사못 고정의 결과 비교

  • Choi, Chang-Hyuk (Department of Orthopaedic Surgery, Catholic University of Daegu, College of Medicine) ;
  • Kim, Shin-Kun (Department of Orthopaedic Surgery, Catholic University of Daegu, College of Medicine) ;
  • Han, Bo-Ram (Department of Orthopaedic Surgery, Catholic University of Daegu, College of Medicine)
  • 최창혁 (대구가톨릭대학교 의과대학 정형외과학교실) ;
  • 김신근 (대구가톨릭대학교 의과대학 정형외과학교실) ;
  • 한보람 (대구가톨릭대학교 의과대학 정형외과학교실)
  • Published : 2008.12.15

Abstract

Purpose: We compared the results of arthroscopic Bankart repair using metal and biodegradable anchor fixation. Materials & Methods: We reviewed 26 patients with anterior shoulder instability treated by arthroscopic Bankart repair from October, 2006, to March, 2007, 15 patients with metal anchors and 11 patients with biodegradable anchors. The average age was 27.4 years old (range: 17~55) and mean follow-up was 14 months (range: 12~17 months). Functional outcome was evaluated using the Korean Shoulder Score for Instability (KSSI), Rowe's Bankart Grading scale (RBGS), ASES score, and UCLA scores. Results: In the metal-anchor group, the improvements of mean KSSI, ASES, UCLA score, and RBGS were 20.6, 24.0, 4.0, and 45.5, respectively. In the biodegradable anchor group, improvements of mean KSSI, ASES, UCLA score, and RBGS were 21.0, 23.6, 4.6, and 48.9. The improvements in final outcomes were not significantly different (p>.05). One metal problem and one traumatic redislocation occurred in the metal group. Conclusion: Both techniques produced satisfactory outcomes in the treatment of traumatic anterior instability. The biodegradable anchor group could also avoid problems with metal anchors.

목적: 본 연구의 목적은 관절경하 Bankart 수복술에서 금속 봉합나사못과 생체흡수성 봉합나사못을 사용 시의 결과를 비교하는데 있다. 대상 및 방법: 2006년 10월에서 2007년 3월까지 견관절 전방 불안정에 대해 관절경하 Bankart 수복술을 시행한 26명을 대상으로 하였고, 금속 봉합나사못 군(GI)은 15명, 생체흡수성 봉합나사못 군(GII)은 11명이었다. 조사대상의 평균연령은 27.4세였고, 평균 추시기간은 14개월이었다. 기능평가는 KSSI 점수, Rowe 점수, ASES점수, UCLA 점수를 사용하여 평가하였다. 결과: 금속 봉합나사못 군(GI)에서 KSSI, ASES점수, UCLA점수, Rowe 점수들의 평균값의 상승은 각각 20.6, 24.0, 4.0, 45.5이었고, GII에서는 각각 21.0, 23.6, 4.6, 48.9였다. 최종 추시 시 두 군에서 기능평가상 유의한 차이를 보이지 않았지만(p>.05), GII에서 금속돌출로 인한 문제와 외상에 의한 재탈구가 각각 1예씩 있었다. 결론: 두 군 모두 만족스런 결과를 보였으며, 생체흡수성 봉합나사못을 사용할 경우 금속으로 인한 문제를 피할 수 있는 이점이 있어 추천할 만한 술식으로 생각되었다.

Keywords

References

  1. Barber FA, Cawley P, Prudich JF: Suture anchor failure strength: An in vivo study. Arthroscopy, 9: 647-652, 1993. https://doi.org/10.1016/S0749-8063(05)80500-6
  2. Barber FA, Herbert MA, Click JN: The ultimate strength of suture anchors. Arthroscopy, 11: 21-28, 1995. https://doi.org/10.1016/0749-8063(95)90084-5
  3. Berg EE, Oslesby JW: Loosening of a biodegradable shoulder staple. J shoulder Elbow Surg, 5: 76-78, 1996. https://doi.org/10.1016/S1058-2746(96)80035-8
  4. Bostman OM: Intense granulomatous inflammatory lesion associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin Orthop Rel. Res, 278: 178-199, 1992.
  5. Cheng JC, Wolf EM, Chapman JE, Johnston JO: Pigmented villonodular synovitis of the shoulder after anterior capsulolabral reconstruction. Arthroscopy, 13: 257-261, 1997. https://doi.org/10.1016/S0749-8063(97)90166-3
  6. Choi CH, Kwon KW, Kim SK et. al: Recovery of motion fraction and shoulder function after operative treatment of shoulder Instability. J Korean Orthop. Assoc. 34: 839-834, 1999.
  7. C.K. Tan, Inigo G, Bhuvaneshwar M et. al: Arthroscopic stabilization of the shoulder: A Prospective Randomized Study of Absorbable Versus Nonabsorbable suture Anchors. Arthroscopy. Vol 22, No 7 716-720, 2006. https://doi.org/10.1016/j.arthro.2006.03.017
  8. Disegi JA and Wyss H: Implant materials for fracture fixation: A clinical perspective. Orthopedics, 12: 75-79, 1989.
  9. Edwards DJ, Hoy G, Saies AD, Hayes MG: Adverse reactions to an absorbable shoulder fixation device. J shoulder Elbow Surg, 3: 230-233, 1994. https://doi.org/10.1016/S1058-2746(09)80040-2
  10. Fraser RK, Cole WG: Osteolysis after biodegradable pin fixation of fractures in children. J Bone Joint Surg Br, 74: 929-930, 1992.
  11. Geiger DF, Hurley JA, Tovey JA, et al: Results of arthroscopic versus open Bankart suture repair. Clin Orthop Rel, Res, 337: 111-117, 1997. https://doi.org/10.1097/00003086-199704000-00013
  12. Guanche CA, Quick DC, Sodergren KM, et al: Arthroscopic versus open reconstruction of the shoulder in patients with isolated Bankart lesions. AM J Sports Med, 24: 144-148, 1996. https://doi.org/10.1177/036354659602400204
  13. Hollinger JO, Battistone GC: Biodegradable bone repair materials synthetic polymers and ceramics. Clin Orthop, Rel, Res, 207: 290-305, 1986.
  14. Kim SH, Ha KI, Kim SH: Bankart repair in traumatic anterior shoulder instability: open versus arthroscopic technique. Arthroscopy. 18: 755-763, 2002. https://doi.org/10.1053/jars.2002.31701
  15. Lyons FA, Rockwood CA Jr: Current concepts review: Migration of pins used in operations on the shoulder. J Bone Joint Surg Am, 72: 1262-1267, 1990.
  16. Marquardt B, Witt KA, G¨otze C, et al: Long-term results of arthroscopic Bankart repair with a bioabsorbable tack. Am J Sports Med. 34:1906-1910, 2006. https://doi.org/10.1177/0363546506290404
  17. Pihlajamai H, Kinnunen J, Botman O: In vivo monitoring of the degradation process of bioresorbable polymeric implants using magnetic resonance imaging. Biomaterials, 18: 1311-1315, 1997. https://doi.org/10.1016/S0142-9612(97)00068-9
  18. Rehm KE, Helling HJ, Claes LE: Biologisch Abbaubare Osteosynthesematerialien. In: Bute H, Jungiger T, eds. Jahrbuch der Chirurgie. Zupich, Germany: Biermann Verlag, 223-232, 1989.
  19. Shellock FG, Mink JH, Curtin S, Friedman MJ: MR imaging and metallic implants for anterior cruciate ligament reconstruction: Assessment of ferromagnetism and artifact. J Magn Reson Imaging. 2: 225-228, 1992. https://doi.org/10.1002/jmri.1880020217
  20. Weiler A, Hoffmann RFG, Stahelin AC, Helling HJ and Sudkamp NP: Biodegradable implants in Sports Medicine: the Biological Base. Arthroscopy, 16: 305-321, 2000. https://doi.org/10.1016/S0749-8063(00)90055-0
  21. Wetzler JJ, Bartolozzi AR, Gillespie MJ: Fatique properties of suture anchors in anterior shoulder reconstructions: Mitek G II. Arthroscopy, 6: 687-693, 1996.