• Title/Summary/Keyword: Bang Machine noise

Search Result 49, Processing Time 0.025 seconds

Psvchoacoustical Evaluation of Floor Impact Noise (바닥충격음의 심리음향학적 평가)

  • 전진용;정정호;조문재
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.253-258
    • /
    • 2001
  • Floor impact noises in apartment buildings have been investigated as they are most annoying in living environment. Several experiments were undertaken to compare perceived noisiness of floor impact noises generated by bang and tapping machine along with children's jumping and running. Results show that bang noise is more annoying than tapping noise and floor impact noise generated by children is less annoying than the noise generated by machine. The floor impact noise generated by children's jumping and running corresponds well with the bang-machine noise in terms of loudness, unbiased annoyance, ${\Phi}$$\_$0/ and IACC. The noise generated by children is somewhat different from machine noise; in spatial impression the real noise is similar to tapping-machine noise but is less annoying that the machine noises.

  • PDF

Evaluations on isolation method of floor impact sounds by real impact source (실충격원을 고려한 바닥충격음 저감방안의 평가)

  • Yoo, Seung-Yup;Lee, Pyung-Jik;Jeong, Young;Jeon, Jin-Yong;Ryu, Jong-Kwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.366-370
    • /
    • 2006
  • In this study, characteristics of impact force and impact sound of impact source such as bang machine, impact ball, and children's jumping were review. Results of review showed that impact ball has most similar characteristic to real impact sources in terms of objective properties such as impact force and impact sound. The effects of various isolator on floor impact sound were also investigated in apartment building and test facilities building using bang machine an impact ball. From the field measurement, it was found that the difference in reduction sound level between bang machine and impact ball was relatively large and the reduction sound level by impact ball was much larger than bang machine.

  • PDF

Selection of the standard impact sounds similar to the human impact sounds in reinforced concrete floors (실충격음과 표준충격원으로 발생된 바닥충격음의 비교)

  • Sato, Shin-Ichi;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1167-1172
    • /
    • 2007
  • This study investigates human floor impact sounds; not only the children's jumping and running represented by heavy-weight impact source such as bang machine and impact ball but also the high-heel walking and the light weight object dropping represented by tapping machine in the standard measurements. However, due to reliability problems as a standard impactor, bang machine has not been included in the new draft of ISO 10140 Part 3: Measurement of impact sound insulation. Therefore, the procedure to convert the floor impact sound level of the bang machine into that of the impact ball has been demanded because the bang machine has been only the standard heavy-weight standard impact source and much of its data has been collected, This study indicates that the use of impact ball is reliable and that the bang machine data can be successfully converted into the impact ball data in case of box-frame type reinforced concrete structures.

  • PDF

Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance (바닥충격음 측정 및 차음 평가의 방향)

  • Jeong, Jeong-Ho;Jeong, Yeong;Seo, Sang-Ho;Song, Hee-Soo;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

Investigating the Adequacy of Rubber Ball Impactor for Floor Impact Noise Evaluation (바닥충격을 평가를 위한 고무공 충격원의 타당성 검토)

  • Jeong, Jeong-Ho;Lee, Sung-Chan;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.468-473
    • /
    • 2002
  • The purpose of this study was to present the possible use of a new standard impactor, the rubber ball(so called, impact ball), and to assess its evaluation method as for heavy-weight impact in multi-story residential buildings, Several experiments were carried out to investigate the effect of the impact on noise propagation in reinforced concrete buildings. Then, the noise from the impact ball was psychoacoustically evaluated. The correlation between the L-value evaluation methods and auditory responses was also investigated. Results show that the ball noise is quite similar to the jumping noise. The noise level of ball is even higher than the bang machine noise, although it has much lower impact force. It was also found that L-indexing seems to bge inappropriate for evaluation of ball noise.

  • PDF

An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis (시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung;Hong, Geon-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.5
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.

Floor Impact Noise Measurement and Evaluation Method Using Impact Ball (임팩트 볼을 활용한 바닥충격음 측정 및 평가)

  • Jeon, Jin-Yong;Jeong, Jeong-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.10 s.103
    • /
    • pp.1160-1168
    • /
    • 2005
  • Floor impact noise isolation performance of reinforced concrete floors was investigated through new measurement method using impact bail. Strong impact force in Bow frequency band below 63 Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight Impact noise but heavy-weight impact noise measurement and evaluation using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

Characteristics of a Rubber-Ball Impactor to Evaluate Floor Impact Noise (바닥 충격음 평가를 위한 고무공 충격원의 특성)

  • 문형준;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.592-597
    • /
    • 2002
  • The purpose of this study was to analyze the characteristics of a new heavy weight impactor, the Rubber Ball. Until now Bang-machine has been used to measure the heavy impact noise in accordance with JIS A 1418-1. However, various kinds of examination methods have been needed to make an objective observation of insulation capacity for floor impact noises. Two types of experiments were undertaken. First, the experiment about noise was carried out about an apartment building in actual living condition. Then. vibration noises from the impactors were analyzed. The results of this study were as follows : the result of experiment carried out with bonded area of bail was closer to practical experiment than that of non bonded area. In addition, the result about bonded area of ball was more similar to the result which is claimed by H. Tachibana than that about non bonded area. Moreover, it was found that Rubber Ball has more similar vibration characteristics to the real impact noise source than Bang-machine.

  • PDF

Comparison of Impact Sound Insulation Performances of Apartment Floors Against Heavy-weight Impact Sources via Field Measurement Data (공동주택 현장 측정자료를 활용한 중량충격원의 바닥충격음 차단성능 비교)

  • Yun, Chang-Yeon;Yeon, Jun-Oh;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.8
    • /
    • pp.651-658
    • /
    • 2014
  • Notification 2013-611 of MOLIT has come into effect. It relates primarily to new standard impact source. In this study, an in-depth experimental analysis of the difference between a bang machine and an impact ball was performed via field testing of shear wall and flat plate structure at 51 sites. This paper focuses on the difference in single number quantities between a bang machine and an impact ball. At wall thicknesses of 180 and 210 mm in shear wall structure, the single number quantities exhibited differences of 3.1 and 4.5 dB, respectively, and at thicknesses exceeding 250 mm in flat plate structure, the difference was constant at 4.6 dB. With regard to flat plate structures, the single-index difference increased up to 11 dB as the thickness of the floor slab increased. In general, the highest level of contribution for the bang machine was 63 Hz, irrespective of thickness determining bandwidth. The highest level for the impact ball were 63 Hz and 125 Hz. In future research, when reviewing additional field performance measurement data, it will be necessary to consider a detailed examination instead of the current method of uniformly adding 3 dB for all thicknesses and types of structures.

Investigating the adequacy of Rubber Ball Impactor for Floor Impact Noise Evaluation (바닥충격음 평가를 위한 고무공 충격원의 타당성 검토)

  • Hyung Joon, Moon;Jeong Ho, Jeong;Sung Chan, Lee;Jin Yong, Jeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.350.2-350
    • /
    • 2002
  • The purpose of this study was to present the possible use of a new standard impactor, the rubber ball (so-called, impact ball), and to assess its evaluation method as fur heavy-weight impact in multi-story residential buildings. Several experiments were carried out to investigate the effect of the impactor on noise propagation in reinforced concrete buildings. Then, the noise from the impact ball was psychoacoustically evaluated. (omitted)

  • PDF