• Title/Summary/Keyword: Ballast water management system

Search Result 54, Processing Time 0.032 seconds

Sterilization of Seawater for the Ballast Water Management System (선박평형수 관리시스템을 위한 해수 살균법)

  • YUN, YONGSUP;CHOI, JONGBEOM;KANG, JUN;LEE, MYEONGHOON
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.172-172
    • /
    • 2016
  • The International Maritime Organization(IMO) adopted the International Convention for the Control and Management of Ships' Ballast Water and Sediments in 2004 to prevent the transfer of aquatic organisms via ballast water. Forty ballast water treatment systems were granted final approval. A variety of techniques have been developed for ballast water treatment including UV treatment, indirect or direct electrolysis, ozone treatment, chemical compounds and plasma-arc method. In particular, using plasma and ozone nano-bubble treatments have been attracted in the fields. However, these treatment systems have a problem such as remained toxic substance, demand for high power source, low efficiency, ets. In this paper, we present our strilization results obtained from membrane type electrolytic-reduction treatment system The core of an electrolysis unit is an electrochemical cell, which is filled with pure water and has two electrodes connected with an external power supply. At a certain voltage, which is called critical voltage, between both electrodes, the electrodes start to produce hydrogen gas at the negatively biased electrode and oxygen gas at the positively biased electrode. The amount of gases produced per unit time is directly related to the current that passes through the electrochemical cell. From the results, we could confirm the sterilization effect of bacteria such as S. aureus, E. Coli and demonstrate the mechanism of sterilization phenomena by electrolytic-reduction treatment system.

  • PDF

Risk Assessment for Retrofitting an Electrolysis Type Ballast Water Treatment System on an Exiting Vessel (현존선에 전기분해방식 선박평형수 처리장치 설치를 위한 위험도 평가 분석)

  • JEE, Jae-Hoon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.3
    • /
    • pp.665-676
    • /
    • 2017
  • Over the past several years, sea trade have increased traffic by ships which highlighted a problem of unwanted species invading the surrounding seas through ship's ballast water discharge. Maritime trade volume has continuously increased worldwide and the problem still exists. The respective countries are spending billions of dollars in an effort to clean up the contamination and prevent pollution. As part of an effort to solve marine environmental problem, BWM(Ballast Water Management) convention was adopted at a diplomatic conference on Feb. 13 2004. In order to comply harmoniously this convention by each country. This convention will be effective after 12 months from the date which 30 countries ratified accounting for more than 35% of the world merchant shipping volume. On Sep. 8 2016, Finland ratified this convention and effective condition was satisfied as 52 states and world merchant vessel fleet 35.1441%. Thus, after Sep. 8 2017, all existing vessels shall be equipped with BWTS(Ballast Water Treatment System) in accordance with D-2 Regulation, which physically handles ballast water from ballast water exchange system(D-1 Regulation). In this study, we analyzed in detail the optimal design method using the Risk Analysis and Evaluation technique which is mainly used in the manufacturing factory or the risky work site comparing with the traditional design concept method applying various criteria. The Risk Assessment Method is a series of processes for finding the Risk Factors in the design process, analyzing a probility of the accident and size of the accident and then quantifying the Risk Incidence and finally taking measures. In this study, this method was carried out for Electrolysis treatment type on DWT 180K Bulk Carrier using "HAZOP Study" method among various methods. In the Electrolysis type, 63 hazardous elements were identified.

A Study on the Industrial Competitiveness of Ballast Water Management System in Compliance with the International Maritime Organization Ballast Water Management Convention in Korea (우리나라 선박평형수처리시스템(BWMS) 산업의 경쟁력 분석에 관한 연구)

  • Park, Han-Seon;Kim, Bo-Ram;Lee, Jeong-Seok;Chung, Haeng-Un
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.483-492
    • /
    • 2020
  • In this study, we compared and analyzed the Revealed Comparative Advantage (RCA) and Trade Specialization Index (TSI) based on ballast water management systems (BWMS) trade data, which are related to the International Maritime Organization (IMO) Ballast Water Management Convention to suggest the current status of Korea's industrial competitiveness and suggest future development directions for the BWMS industry. As international interest in eco-friendly vessels is expanding, the IMO is engaged in dramatic discussions and agreement-making related to marine emissions of pollutants from ships. IMO member states that must implement this convention are striving to develop technology and secure industrial competitiveness as major industries in the eco-friendly shipping sector, with the BWMS industry experiencing a high market entry barrier and the possibility of the leading market entrants gaining leadership. The Republic of Korea accounts for 17 (approximately 38 %) of the 45 BWMS that received final approval as of October 2019. Based on trade data relating to product codes HS842219, HS84212, and HS89, the RCA index and TSI were calculated and compared. The findings revealed that the Republic of Korea has relative inferiority compared to countries such as Germany and Denmark. Despite this, Korea's favorable industrial environment, which includes several IMO-approved BWMS technologies and the possession of domestic certification institutions, is likely to strengthen its competitiveness in the BWMS market.

Comparison of sampling method of phytoplankton for type approval of ballast water management system (선박평형수처리장치 형식승인을 위한 식물플랑크톤 샘플링 방법 비교)

  • Jang, Pung-Guk;Hyun, Bonggil;Lee, Woo-Jin;Choi, Keun-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.426-433
    • /
    • 2020
  • This study aimed to compare the pretreatment methods of phytoplankton for type approval of the Ballast Water Treatment System (BWMS). The International Maritime Organization (IMO) and the United States Maritime Police (USCG) use two different test methods for this purpose. To compare the two methods, a test for concentration and non-concentration was performed with cultured and natural phytoplankton, and samples from the land-based BWMS test. The extent of damages caused by the process of concentration varied between cultured and natural species, indicating differences depending on the physiological and morphological characteristics of the species. In the land-based test, in the control water with a high biological population, the number of non-concentrated samples was about twice as high as that of the concentrated samples. There was no distinct difference between the two methods in the treated water with a low biological population. Thus, although there is a difference between concentration and non-concentration for phytoplankton sampling, the concentration method can be applied as a method of evaluating BWMS performance. However, a method for evaluating whether live species in treated water may be lost or damaged during the concentration process of sampling should be developed and validated.

Study on the Improvement of Ballast Water Risk Assessment of GloBallast (GloBallast 선박평형수 위해도평가 방법의 개선방안에 관한 연구)

  • Lee, S.G.;Kang, W.S.;Kim, E.C.;Shin, K.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.4
    • /
    • pp.224-229
    • /
    • 2011
  • Recently, the management of the marine invasive alien species introduced by ballast water has come to the core as an urgent task. Because, hazardous organisms cause harmful effects on the ecosystem. Hazardous organisms also negatively affect fisheries, commercial shipping activities, and marine resources. In this regard, IMO used to operate GloBallast, Ballast Water Risk Assessment System, in order to manage the introduction of invasive species by ballast water. GloBallast is constructed to assess the relative risk due to the movement of ballast water between nations, using the volume and the number of times of ballast water discharge, the environmental similarity between ports, and the abundance of hazardous species as the main factors. According to the results of the demo-operation of GloBallast, it was found out that the environmental similarity factor had affected most highly the results of risk assessment. Therefore, in this study, the correlation between the main factors used in GloBallast risk assessment were re-examined, and some methods were suggested in order to reflect these main factors in the risk assessment more reasonable.

Application of Neutral Red Staining Method to Distinguishing Live and Dead Marine Plankton for the Investigation of Efficacy of Ship's Ballast Water Treatment System (선박평형수 처리 시스템 효율 검증을 위한 해양 플랑크톤 생사판별시 Neutral red 염색법 적용 가능성 연구)

  • Hyun, Bonggil;Shin, Kyoungsoon;Chung, Hansik;Choi, Seo-Yeol;Jang, Min-Chul;Lee, Woo-Jin;Choi, Keun-Hyung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.4
    • /
    • pp.223-231
    • /
    • 2014
  • In order to prevent the spread of non-indigenous aquatic species through the ballast water in commercial ships, International Maritime Organization (IMO) adopted in 2004 the International Convention for Control and Management of Ship's Ballast Water and Sediments. The Convention mandates treatment of ballast water for most transoceanic voyages and its confirmation of treatment is made with plankton live/dead assay. Fluorescein diacetate assay (FDA), which produces bright green light for live phytoplankton, has been a de facto standard method to determine the survival of marine plankton, but its staining efficacy has been in dispute. In the present study, we examined the limitation of FDA, and compared its efficacy with Neutral red (NR) staining, another promising assay and widely used especially for zooplankton mortality. For all phytoplankton species studied in the present study, except Ditylum brightwellii, the staining efficiency was <50% with FDA. The green FDA fluorescence interfered with phytoplankton autofluorescence in most samples. In contrast, NR assay stained over 90% of both phytoplankton and zooplankton species tested in this study. FDA assay also showed that green FDA fluorescence rapidly faded when phytoplankton cells were exposed to microscope light. Both FDA and NR assay were negative on formalin-killed individuals of both phytoplankton and zooplankton species. Our results suggest that NR assay is more effective for determining the survival of marine plankton and can be applied to test the efficacy of ballast water treatment.

Effect of Electrochemical Treatment on the Chlorine Generation Efficiency of Ballast Water in the Brackish Zone (기수지역 선박평형수의 염소 생성 효율에 미치는 전기화학 처리의 영향)

  • Choi, Yong-Sun;Lee, You-Kee
    • Korean Journal of Materials Research
    • /
    • v.29 no.1
    • /
    • pp.16-22
    • /
    • 2019
  • Indirect oxidation using chlorine species oxidizing agents is often effective in wastewater treatment using an electrochemical oxidation process. When chlorine ions are contained in the wastewater, oxidizing agents of various chlorine species are produced during electrolysis. In a ballast water management system, it is also used to treat ballast water by electrolyzing seawater to produce a chlorine species oxidizer. However, ballast water in the brackish zone and some wastewater has a low chlorine ion concentration. Therefore, it is necessary to study the chlorine generation current efficiency at various chlorine concentration conditions. In this study, the chlorine generating current efficiency of a boron-doped diamond(BDD) electrode and insoluble electrodes are compared with various chloride ion concentrations. The results of this study show that the current efficiency of the BDD electrode is better than that of the insoluble electrodes. The chlorine generation current efficiency is better in the order of BDD, MMO(mixed metal oxide), $Ti/RuO_2$, and $Ti/IrO_2$ electrodes. In particular, when the concentration of sodium chloride is 10 g/L or less, the current efficiency of the BDD electrode is excellent.

Design and Fabrication of a Ballast Water Treatment System Using UV Lamps (자외선램프를 이용한 선박평형수 처리시스템의 설계 및 제작)

  • Pyo, Tae-Sung;Cheon, Sang-Gyu;Park, Dae-Won;Choi, Sung-Kuk;Kim, Seong-Yeon;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.952-958
    • /
    • 2009
  • The International Maritime Organization (IMO) has adopted the ballast water management convention at a diplomatic conference in early 2004 that all ships should be equipped with a treatment system from 2010 gradually. In this paper, the disinfection characteristic of ultra-violet (UV) rays was studied and a ballast water treatment system (BWTS) which can treat $50m^3$/h sea water was manufactured. The system consists of a disinfection chamber with six 3.5 kW UV lamps which are operated by magnetic ballasts, a programmable logic controller (PLC) and set of pipe lines. The biological disinfection efficacy of the prototype BWTS was evaluated following the IMO rules using zooplankton such as Artemia and Rotifer species for the size over $50{\mu}m$, and phytoplankton such as Tetraselmis and Thalassiosira species for the size between 10 to $50{\mu}m$. From the experimental results, the disinfection efficacy was 99.99 % that meets the IMO requirement. However, more studies on an energy saving system are needed because the consumption power of the prototype system is as high as over 21 kWh for $50m^3$/h.

Study of Factors for development of Advanced Media filter for Ballast water Treatment (밸러스트 수 처리용 메디아 필터 개발을 위한 여과특성에 관한 연구)

  • Park, Seon-Jeong;Lim, Jae-Dong;Kim, Dong-Geun;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.499-503
    • /
    • 2008
  • As the conference result of MEPC in IMO, development of ballast water management system corresponding to newly established ballast water management standard (D2 regulation) of shipping is being made an active progress over the whole world. The ballast water management system should treat particular material of more than $10{\mu}m$ in high capacity of more than 500t per hour in the event of filtration process. Also, it is very difficult to develop a practical management system since a limited element which a narrow space of the ship should be designed in the minimal volume is assumed. Therefore, the study promoted a study on the next generation auto back wash media filter to overcome such a limited element. Also, the study performed pressure and flux measurement test followed by thickness of each filter medium for filtration by each size to grasp a relation between absorption and pressure at the time of vacuum filtration and mechanical analysis and turbidity change observation of filtered water after vacuum filtration.

Consideration on the Ballast Water Treatment System Technology and its Development Strategies (IMO 선박평형수 처리장치 기술과 발전 방향에 대한 고찰)

  • Kim, Eun-Chan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.4
    • /
    • pp.349-356
    • /
    • 2012
  • For smooth implementation of the IMO Ballast Water Management Convention that is to come into effect in the near future, IMO and Member States are working on the development of various technologies and establishment of legislative action. Ballast water treatment systems are essential, yet difficult technologies, as they need not only to treat living organisms, but also define whether they are viable or not, count the number of viable organisms, and present quantitative results of the concentration of active substances. Despite the fact that the Convention is looming in the near future, the issues mentioned above obstruct the setup of consensual technologies for performance reliability of the treatment system and analysis method of efficacy test results. This paper considers the unsolved issues of the ballast water treatment technologies, and presents guidelines to solve these issues.