• 제목/요약/키워드: Ball-on-3-ball test

검색결과 331건 처리시간 0.028초

알루미나-유리 복합체용 글래스의 조성에서 $CeO_2$의 함량변화가 강도에 미치는 영향 (EFFECT OF $CEO_2$ ADDITION IN GLASS COMPOSITION ON THE STRENGTH OF ALUMINA-GLASS COMPOSITES)

  • 이화진;송광엽;강정길
    • 대한치과보철학회지
    • /
    • 제38권5호
    • /
    • pp.595-605
    • /
    • 2000
  • Dental ceramics have good aesthetics, biocompatibility, low thermal conductivity, abrasion resistance, and color stability. However poor resistance to fracture and shrinkage during firing process have been limiting factors in their use, particularly in multiunit ceramic restorations. A new method for making all-ceramic crowns that have high strength and low processing shrinkage has been developed and is referred to as the Vita In-Ceram method. This study was performed to investigate the effect of $CeO_2$ addition in borosilicate glasses on the strength of alumina-glass composites. Porous alumina compacts were prepared by slip casting and sintered at $1,100^{\circ}C$ for 2 hours. Dense composites were made by infiltration of molten glass into partially sintered alumina at $1,140^{\circ}C$ for 4 hours. Specimens were polished sequentially from #800 to #2000 diamond disk. and the final surface finishing on the tensile side was received an additional polishing sequence through $1{\mu}m$ diamond paste. Biaxial flexure test was conducted by using ball-on-three-ball method at a crosshead speed of 0.5mm/min. To examine the microstructural aspect of crack propagation in the alumina-glass composites, Vickers-produced indentation crack was made on the tensile surface at a load of 98.0 N and dwell time of 15 sec, and the radial crack patterns were examined by an optical microscope and a scanning electron microscope. The results obtained were summarized as follows; 1. The porosity rates of partially sintered alumina decreased with the rising of firing temperature. 2. The maximum biaxial flexure strength of 423.5MPa in alumina-glass composites was obtained with an addition of 3 mol% $CeO_2$ in glass composition and strength values showed the aspect of decrease with the increase of $CeO_2$ content. 3 The biaxial flexure strength values of alumina-glass composites were decreased with rising the firing temperature. 4. Observation of the fracture surfaces of alumina-glass composites indicated that the enhancement of strength in alumina-glass composites was due to the frictional or geometrical inter-locking of rough fracture surfaces and ligamentary bridging by intact islands of materials left behind the fracture front.

  • PDF

호흡근훈련 유무에 따른 안정화 운동이 건강한 성인의 호흡 기능과 자세 동요에 미치는 영향 (Effects of Stabilization Exercise with and without Respiratory Muscle Training on Respiratory Function and Postural Sway in Healthy Adults)

  • 서혜리;안덕현;김미현;고민주;오재섭
    • 대한통합의학회지
    • /
    • 제11권3호
    • /
    • pp.25-33
    • /
    • 2023
  • Purpose : Stabilization exercise and respiratory muscle training are used to train trunk muscles that affect postural control and respiratory function. However, there have been no studies that combine stabilization exercise and respiratory muscle training. The purpose of this study is to investigate effects of stabilization exercise with and without respiratory muscle training on respiratory function and postural sway. Methods : Fifteen healthy adults were recruited for this experiment. All the subjects performed stabilization exercise with and without respiratory muscle training. For stabilization exercise with respiratory muscle training, the subjects sat on a gym ball wearing a stretch sensor. The subjects inspire maximally as long as possible during lifting one foot off the ground, alternately for 30 seconds. The stretch sensor was placed on both anterior superior iliac spine (ASIS), and the stretch sensor was used to monitor inspiration. For stabilization exercise without respiratory muscle training, the subjects sat on a gym ball and lifted one foot off the ground, without respiratory muscle training. Kinovea program used to investigate postural sway tracking during exercise. The maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP) were measured using a spirometer to investigate changes of respiratory muscle strength before and after exercise. A paired t-test was used to determine significant differences postural sway tracking, MIP, and MEP between stabilization exercise with and without respiratory muscle training. Results : There were significantly lower a distance of postural sway tracking during stabilization exercise with respiratory muscle training, compared with stabilization exercise without respiratory muscle training (p<.05). The MIP and MEP were significantly increased after stabilization exercise with respiratory muscle training compared with before stabilization exercise with respiratory muscle trianing (p<.05). Conclusion : The results of this study suggest that stabilization exercise with repiratory muscle training would be recommended to improve postural control and respiratory muscle strength.

플립 칩 BGA 솔더 접합부의 열사이클링 해석 (Thermal Cycling Analysis of Flip-Chip BGA Solder Joints)

  • 유정희;김경섭
    • 마이크로전자및패키징학회지
    • /
    • 제10권1호
    • /
    • pp.45-50
    • /
    • 2003
  • 시스템 보드에 플립 칩 BGA가 실장된 3차원 유한요소 해석 모델을 구성하여 열사이클시험 과정에서 발생되는 솔더 접합부의 피로수명을 예측하였다. 피로 모델은 Darveaux의 경험식에 기초하여 비선형 점소성 해석을 수행하였다. 해석은 4종류의 열사이클시험 조건과 패드구조, 솔더 볼의 조성과 크기의 변화에 따라 발생하는 크리프 수명을 평가하였다. 해석결과 $-65∼150^{\circ}C$의 열사이클시험 조건에서 가장 짧은 피로수명을 보였으며, $0∼100^{\circ}C$ 조건과 비교하면 약 3.5 배 정도 증가하였다. 동일한 시험조건에서 패드구조 변화에 따른 피로수명 차이는 SMD구조가 NSMD구조에 비해 약 5.7% 증가하였다 결과적으로 솔더 접합부에서 크리프 변형에너지 밀도가 높으면 피로수명은 짧아지는 것을 알 수 있었다

  • PDF

플라즈마 코팅한 주조용 알루미늄합금의 마찰 및 마멸특성 (Friction and Wear Characteristics of Plasma Coated Surface of Casting Aluminum Alloy)

  • 채영훈;임정일;박준목;김석삼
    • 대한기계학회논문집A
    • /
    • 제21권5호
    • /
    • pp.791-799
    • /
    • 1997
  • The wear characteristics and wear mechanisms of plasma sprayed Al/sub 2/ O/sub 3/-40%TiO/sub 2/ and Cr/sub 2/O/sub 3/ deposited on casting aluminum alloy(AC4C) were investigated. Specimens were processed for various coating thicknesses. Ball on disk type wear tester was used for wear test. The scratch test on plasma sprayed coating surface showed that critical load to break the coating layer was greater than 40 N. The critical load increase with the increase of coating thickness of specimens. The friction coefficient of Cr/sub 2/O/sub 3/ coating layer was less than that of Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer. The wear resistance of Cr/sub 2/O/sub 3/ coating layer was greater than that of Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer. Microscopic observation of worn surfaces was made by SEM. SEM observation showed that the main mechanism of wear for Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer was abrasive wear under 50 N. For the case of Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer, as the surface cracks perpendicular to sliding direction propagated, the wear debris was generated in wear track. However, the main mechanism of wear for Cr/sub 2/O/sub 3/ coating layer was brittle fracture under 150 N.

냉간단조에서 금형 열박음 영향의 정량적 분석 (Quantitative Analysis of Effect of Shrink Fit in Cold Forging)

  • 이추실;김민철;정동찬;손요헌;전만수
    • 한국정밀공학회지
    • /
    • 제28권3호
    • /
    • pp.301-307
    • /
    • 2011
  • In this paper, effects of major design parameters of cold forging dies on die mechanics are quantitatively investigated with emphasis on shrink fit using a thermoelastic finite element method. A ball-stud cold forging process found in a cold forging company is selected as a test process and the effects of die insert material, magnitude of shrink fit, dimension of shrink ring, number of shrink rings, partition of die insert and clamping force on effective stress and circumferential stress are analyzed. It has shown that the number of shrink rings, magnitude of shrink fit, and Young's modulus of die insert material have strong influence on compressive circumferential stress in die insert but that the influence of the other design parameters is relatively weak.

기계적 연마 전처리가 인산망간 피막의 윤활 특성에 미치는 영향 (Effect of Mechanical Polishing Pretreatment on Tribological Properties of Manganese Phosphate Coating of Carbon Steel)

  • 김호영;노영태;전준혁;강호상
    • 한국표면공학회지
    • /
    • 제52권6호
    • /
    • pp.350-356
    • /
    • 2019
  • In this study, the effect of mechanical polishing of carbon steel on the tribological properties of manganese phosphate coating on carbon steel has investigated. The microstructure, surface morphology and chemical composition were analyzed by SEM, EDS, and XRD. The surface roughness test was carried out in order to calculate Rvk value by 3D laser microscopy. Also, the tribology property of manganese phosphate coating was tested by ball-on disk. In the results of EDS analysis, coating layer consists of elements such in Mn, P, Fe, and O. XRD showed that (Mn,Fe)5H2(PO4)4·4H2O in manganese phosphate coating layer was formed by the chemical reaction between manganese phosphate and elements in carbon steel. As the mechanical polishing degree increased, the friction coefficient was reduced. The rougher the mechanical polishing degree, the better corrosion resistance was obtained.

플립칩 패키지 BGA의 전단강도 시험법 표준화 (Regulation in Shear Test Method for BGA of Flip-chip Packages)

  • 안지혁;김광석;이영철;김용일;정승부
    • 마이크로전자및패키징학회지
    • /
    • 제17권3호
    • /
    • pp.1-9
    • /
    • 2010
  • 본고에서는 마이크로 접합을 위한 솔더볼 또는 범프의 기계적 신뢰성 평가에 사용되는 전단시험의 표준화 규격에 대해 고찰해 보았다. 전단시험에서 중요한 실험 조건 중 하나인 전단속도는 low speed shear test와 high speed shear test로 구분 된다. 전단속도가 빨라질수록 솔더볼에 가해지는 충격이 커지기 때문에, 소성변형에 대한 저항성이 커지게 되고, 전단강도가 커지게 된다. 그리고 이 결과는 전산모사를 통하여 확인할 수 있다. 또 하나의 중요한 실험 조건으로 전단툴의 높이가 있다. 일반적으로 전단툴의 높이가 높을수록 전단강도 값은 낮아지게 되는데, 여러 국제 규격에서 제시한 솔더볼 높이의 25% 지점을 초과한 높이에서 전단시험을 진행했을 때에는 전단시험이 진행되는 접합 계면의 면적이 줄어들어 실험결과의 신뢰도가 떨어지게 된다. 이와 같이 전단속도와 툴의 높이 등의 실험조건들이 구체적으로 규격화 되어있지 않은 채 진행 되면, 실험 결과의 신뢰도가 떨어지고, 각 계에서 진행된 연구결과를 상호 비교하기가 어렵다. 따라서 효율성을 고려한 간접 시험법 개발 및 최신 패키징기술을 반영된 특성평가 시험법의 규격, 그리고 다양한 시험 표준화는 결국 마이크로 전자패키지의 고 신뢰성으로 나타날 것이라 생각된다.

곡률이 다른 직교이방성 CFRP 적층쉘의 관통파괴특성 (Penetration Fracture Characteristics of Orthotropic CFRP Laminates Shells according to Curvature)

  • 양용준;편석범;차천석;양인영
    • 한국안전학회지
    • /
    • 제31권6호
    • /
    • pp.6-11
    • /
    • 2016
  • CFRP composite laminates are widely used as structural materials for airplanes, automobile and aerospace vehicles because of their high strength and stiffness. This study aims to examine an effect of curvature on the penetration fracture characteristic of an orthotropic composite laminated shell. For the purpose, we manufactured orthotropic CFRP shell specimen with different curvatures, and conducted a penetration test using an air-gun. Those specimens were prepared to varied curvature radius(${\infty}$, 200mm, 150mm and 100mm)and were stacked to $[O^{\circ}{_3}/90^{\circ}{_3}]_s$. When the specimen is subjected to transverse impact by a steel sphere(${\Phi}10$), the velocity of steel sphere was measured both before and after impact by determining the time for it to pass two ball-screen sensors located a known distance apart. As the curvature increases, the absorption energy and the critical penetration energy increased linearly because the resistance to the bending moment. Patterns of cracks caused by the penetration of CFRP laminated shells included fiber breakage, lamina fracture, matrix crack interlaminar crack and intralaminar crack.

공동주택 중량바닥충격음 현장측정을 통한 차단성능 평가방법의 비교검토 연구 (A Study of Rating Method Comparison for Heavy-weight Floor Impact Sound based on the Field Test Data in Apartment Houses)

  • 신훈;백건종;국찬;송민정;김선우
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.187-194
    • /
    • 2010
  • Heavy-weight floor impact sound insulation performance criteria have been effective in Korea since the regulation which enforces the standard thickness of slabs in domestic apartment houses should be constructed by 180mm or 210mm was adopted. But every slab does not satisfy this criteria. So, review on existing floor impact sound insulation performance is needed to propose some basic materials for the revision of rating method. To achieve this goal, 63 field test data were checked and analyzed. The results of this study are as follows ; 1) The 210mm thickness slab has the characteristics of deeper level decrease above 120Hz frequency band than that of 180mm thickness slab's. 2) 27.5% of 180mm thickness slabs were satisfied the floor impact sound insulation performance criteria, whereas 65% of 210mm slabs do. 3) Among the main contribution frequency bands for the determination of single rating index, 63Hz was shown as the most contributive band in 210mm slabs. 4) In comparison of single rating index between bang machine test and ball test. there is a big difference between the two and this phenomenon is frequent in 210mm slab results. 5) Rating Methods for the analysis of cross-correlation between the amount of rating, the usefulness of the arithmetic mean could be secured.

컴포넌트에서의 비정상적인 금속간화합물 성장이 보드 레벨 기계적 신뢰성에 미치는 영향 (The Effect of Abnormal Intermetallic Compounds Growth at Component on Board Level Mechanical Reliability)

  • 최재훈;함현정;황재선;김용현;이동춘;문점주
    • 마이크로전자및패키징학회지
    • /
    • 제15권2호
    • /
    • pp.47-54
    • /
    • 2008
  • 컴포넌트에서의 비정상적인 금속간화합물 성장이 보드 레벨 기계적 신뢰성에 미치는 영향을 연구하기 위하여, 전기 도금된 Ni/Au UBM과 Sn2.5Ag0.5Cu 솔더의 리플로우 횟수 및 고온 시효 시간에 따른 금속간 화합물 성장거동을 관찰하였다. 각 조건별로 처리된 컴포넌트에서 솔더 접합부의 기계적 특성을 비교하기 위하여, 전단 속도 변화에 따른 볼 전단 시험을 실시하여 전단에너지 값을 측정하였다. 마지막으로, 보드 레벨에서의 기계적 신뢰성 시험을 위하여 조건별로 처리된 컴포넌트를 PCB 보드에 실장하여, 3점 굽힘 시험 및 충격 시험을 실시한 후 파괴모드를 분석하였다.

  • PDF