• 제목/요약/키워드: Ball bar system

검색결과 41건 처리시간 0.024초

Attachment systems for mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Lee, Jeong-Yol;Shin, Sang-Wan;Bryant, S. Ross
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.197-203
    • /
    • 2012
  • PURPOSE. The aim of this systematic review was to address treatment outcome according to attachment systems for mandibular implant overdentures in terms of implant survival rate, prosthetic maintenance and complications, and patient satisfaction. MATERIALS AND METHODS. A systematic literature search was conducted using PubMed and hand searching of relevant journals considering inclusion and exclusion criteria. Clinical trial studies on mandibular implant overdentures until August, 2010 were selected if more than one type of overdenture attachment was reported. Twenty four studies from 1098 studies were finally included and the data on implant survival rate, prosthetic maintenance and complications, patient satisfaction were analyzed relative to attachment systems. RESULTS. Four studies presented implant survival rates (95.8 - 97.5% for bar, 96.2 - 100% for ball, 91.7% for magnet) according to attachment system. Ten other studies presented an implant survival rate ranging from 93.3% to 100% without respect to the attachment groups. Common prosthetic maintenance and complications were replacement of an assay for magnet attachments, and activation of a matrix or clip for ball or bar attachments. Prosthetic maintenance and complications most commonly occurred in the magnet groups. Conflicting findings were found on the rate of prosthetic maintenance and complications comparing ball and bar attachments. Most studies showed no significant differences in patient satisfaction depending upon attachment systems. CONCLUSION. The implant survival rate of mandibular overdentures seemed to be high regardless attachment systems. The prosthetic maintenance and complications may be influenced by attachment systems. However patient satisfaction may be independent of the attachment system.

레이디얼 피스톤 펌프의 피스톤 접촉 메커니즘 개발 (Development of piston contact mechanism for radial piston pump)

  • 함영복;차재곤;김대명;공태우;윤소남;안국영;권병수
    • 유공압시스템학회논문집
    • /
    • 제7권1호
    • /
    • pp.1-5
    • /
    • 2010
  • This paper presents the experimental results of the radial piston type oil pump with new mechanism for a metal diaphragm hydrogen compressor. Generally, metal diaphragm type hydrogen compressor systems are operated by oil hydraulic power. In this system an oil compensating pump has been demanded to compensate for a leakage oil head chamber. The metal diaphragm type hydrogen compressor consists of an oil compensating pump, commonly used hydraulic piston pump and driven by main crank shaft. The radial piston type oil compensating pump with new rolling contacted piston mechanism is developed and experimented. The developed piston element of the radial piston pump consists of piston, steel ball, return spring, two check valves, eccentric cam and ball racer. In this study, designed 4 type pistons as and orifice hole. Operating characteristics and pressure ripple characteristics are tested under no load to 60bar loaded with every 20bar increasing step and pressure ripple and flow rate are experimentally investigated.

  • PDF

하이브리드 로켓의 추력제어를 위한 산화제 유량제어 연구 (Oxidizer Flow Rate Throttling for Thrust Control of Hybrid Rocket)

  • 김계환;문근환;김진곤;문희장
    • 한국항공운항학회지
    • /
    • 제22권4호
    • /
    • pp.93-98
    • /
    • 2014
  • In this study, control of oxidizer mass flow rate and verification of control system were performed for hybrid rocket thrust control application. Oxidizer flow control system consists of ball valve and stepping motor where gaseous oxygen was used for oxidizer at feeding pressure of 10, 20 and 30 bar. According to experimental results, the oxidizer mass flow rate showed a relatively linear increment as ball valve open angle increases regardless of feeding pressure. In addition, the level of the oxidizer flow rate was kept almost constant at each sequence of flow control with ball valve during the 20 seconds of operation.

리니어 스케일을 이용한 NC 선반의 원 운동정도 측정 시스템의 구성 (Organization of Circular Motion Accuracy Measuring System of NC Lathe using Linear Scales)

  • 김영석;김재열;김종관;한지희;정정표
    • 한국공작기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.1-6
    • /
    • 2004
  • Measurements of circular motion accuracy of NC lathe have achieved with ball bar systems proposed by Bryan, but the ball bar systems have ifluenced on the measuring data by way of the accuracy of the balls and the contacts of balls and bar seats. Therefore in this study, error data during of circular motion of ATC(Automatic Tool Changer) of NC lathe will be acquired by reading zx plane coordinates using two optical linear scales. Two optical linear scales of measuring unit are fixed on z-x plane of NC lathe, and the moving part is fixed to ATC and then is made to receive data of coordinates of the ATC at constant time intervals using tick pulses comming out from computer. And then, error data files of radial direction of circular motion are calculated with the data read, and the aspect of circular motion are modeled to plots, and are analysed by means of statistical treatments of circularity, means, standard deviations etc.

스프링하중을 고려한 디젤차량용 오버플로우 밸브 성능평가 (Overflow Valve and Performance Evaluation System for Diesel Cars based on Spring Load)

  • 윤달환
    • 전기전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.200-204
    • /
    • 2016
  • 본 연구에서는 유로형(EURO type) 클린 디젤 CRDI(common rail direct injection) 엔진용 오버플로우 밸브 성능 평가 시스템을 구현한다. 친환경 조건에 맞도록 정밀 기능을 구비한 오버플로우를 위해 스프링의 하중을 고려한 구현이 중요하다. 특히 정밀제어에 따른 디젤 차량의 성능평가는 연비 향상과 환경 규제 만족이 필연적이다. 이에 성능평가를 위한 평가 알고리즘의 기본 조건은 100cc 미만에서 3.0 bar, 150 cc 이상에서 3.3 bar, 250 cc이상에서 4.0 bar를 사용하여 시험한다.

ALBC3 합금의 해수 내 전기화학적 특성에 미치는 쇼트피닝 분사압력의 영향 (Effects of Shot Peening Projection Pressure on Electrochemical Characteristics of ALBC3 Alloy in Seawater)

  • 한민수;임명환;김성종
    • 한국표면공학회지
    • /
    • 제47권1호
    • /
    • pp.25-32
    • /
    • 2014
  • The effects of shot peening pressure on electrochemical and surface morphological characteristics of ALBC3 alloy were investigated in this work. The surface hardness of ALBC3 alloy was improved by shot peening process under all shot peening pressures between 2 and 5 bar, and the hight value of surface hardness was observed to be about 420 Hv at 4 bar of the shot peening pressure. The shot peened surface presented very rough surface due to shot ball collision. The result of anodic potentiodynamic polarization in seawater revealed that there is no significant difference between the shot peened and non-shot peened specimen in terms of corrosion characteristics. Therefore, the optimum projection pressure is determined to be 4 bar.

탄성 운동을 고려한 세탁기 시스템의 동력학 모델링 (Dynamic Modeling of Washing System with Elastic Motion)

  • 오혁진;이우식
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.47-54
    • /
    • 2003
  • The rotating of rotatory unit with its structural unbalance mass and laundry is making the main vibration problem in a vertical axis washing machine. For reducing vibration problem total washing system hung on the case by its suspension system which is constitute of spring, damper and suspension bar and hydraulic balancer is attached at the upper rim of spin basket. In this paper, we make the dynamic model of washing system of its rigid body motions by 6 degree of freedoms. Hydraulic balancer is modeled by one degree of freedom like auto ball balancer. Elastic motions of washing system have found by method of analytic, experimental and FEM. And we consider first bending mode of each suspension bar and first circumferential mode of assy tub. So, the total washing system is modeled by 12 degree of freedoms. Equations of motion for total washing system have derived, and we perform the dynamic simulation tests.

  • PDF

CAD-CAM으로 제작된 임플란트 피개의치를 이용한 무치악 환자의 보철 수복 증례 (Rehabilitation of the edentulous patient with implant overdenture using CAD-CAM denture system: A case report)

  • 이한나;심지석;이정열
    • 대한치과보철학회지
    • /
    • 제60권4호
    • /
    • pp.374-381
    • /
    • 2022
  • 본 증례는 74세 남환으로 20년 전 제작한 하악 임플란트 피개의치의 잦은 탈락을 주소로 내원하였다. 기존 의치 사용 시 수직고경이 감소되었으며, 상악 총의치는 입술 지지 및 유지력이 부족하였으며, 하악 피개의치는 bar attachment 손상으로 clip의 유지력 부족이 관찰되었다. 손상된 bar attachment를 제거 후 ball attachment로 교체하였으며, DENTCATM Tray를 이용하여 인상 채득, 수직고경을 측정하고, 고딕 아치 기록방법으로 중심위를 결정하여 교합기록을 시행하였다. 채득한 인상체를 스캔하여 소프트웨어를 이용하여 최종 의치의 형태를 디자인하였고, 3D 프린터로 시적의치를 제작하였다. 제작된 시적의치를 장착하여 교합평면 및 교합관계, 안모 형태, 발음 등을 평가한 후 교합기록을 하였으며, 이를 바탕으로 최종 의치를 제작하였다. 최종 의치의 내면 조정 및 양측성 균형교합을 형성하였으며, 하악 의치에서는 직접법으로 attachment를 연결하였다. 새로 제작된 상하악 의치 사용 시, 수직고경의 증가 및 입술지지를 회복하여 개선된 안모가 관찰되었으며, ball attachment 교체로 하악 임플란트 피개의치의 유지력이 증가하여 기능적으로도 만족할 만한 결과를 얻었기에 이를 보고하는 바이다.

Machining Center의 2차원 원호보간정밀도 진단 System의 개발 (A development of accuracy diagnostic system 2-dimensional circular interpolation of machining centers)

  • 김정순;남궁석;제정신
    • 한국정밀공학회지
    • /
    • 제10권2호
    • /
    • pp.54-65
    • /
    • 1993
  • The paper describes and alternative method based on a new idea to measure the circular movement of machining centers. ISO has employed three testing methods for the acceptance tests of machine tools; the first is a rotating one-dimensional probe method, the second is a two-dimensional probe and a master circular ring, and the third is a kinematic ball bar. The last two methods were proposed and introduced by W. Knapp and J. B. Bryan, respectively. The newly developed method is superior to above two methods; the rotating angle can be detected and the rotating radius is variable. Circular movement errors of machining centers were investigated by the analysis of data measured by R- .THETA. method. Followint observations are obtained 1) The errors which depend on positions, i.e., periodical errors by the pitch of ball screws, errors by compensation of backlash and errors by perpendicularity of X and Y-axis, were analyzed. 2) The errors which depend on NC control system, i.e., errors by the unbalance of position-loop-gaians, errors by velocity-loop-gains and errors by feed speeds, were quantiatively analyzed. 3) The method of extracting error information, which uses moving technique of averaging angle and fourier's analysis data mesured by the R- .THETA. method, was proposed.

  • PDF