• Title/Summary/Keyword: Ball Movement

검색결과 154건 처리시간 0.143초

자연치열에 설치한 pivot의 전후방 일치변화에 따른 하악의 moment에 관한 연구 (A STUDY ON THE MANDIBULAR MOMENTS ACCORDING TO ANTERO-POSTERIOR PLACEMENT OF PIVOT ON LOWER NATURAL DENTITION)

  • 이현식;박남수;최대균
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.394-410
    • /
    • 1993
  • This study was accomplished for appreciation of the mandibular moments according to antero- posterior movement of pivot placed on the lower natural dentition. For this study, 20 subjects(male, $21\sim30$ yrs., average age 24) in the category of normal occlusion were selected, and the intraoral Vitallium clutches were cast and fabricated for each subjects. A 2-dimension PSD(Position Sensitive Detector, Hamamatsu Photonics Co., Japan) was attached to maxillary clutch in a mode of three dimensional control and LED (Light Emit Diode, Hamamatsu Photonics Co., Japan) was set up on mandibular clutch. Both clutches were set into oral cavity of each subjects and adjusted. Then the subjects were allowed to intercuspated with maximal bite force while the pivoting ball in the mid-line moving from anterior toward posterior position. The displacement scales were recorded by CCD camera(Sony, CCD-TR-705) and VCR, The conclusions were as follows : 1. When the subject was allowed to bite the metal pivoting ball in the midline of lower dentition with maximal bite force voluntarily while moving from lower central incisor to canine, 1st premolar, End premolar, 1st molar and 2nd molar. The lever actions on the pivot were revealed in all subjects. The equilibrium of moment were revealed on the pivots of 1st premolar(14 subjects), End premolar(4 subjects), and canine(2 subjects) areas. 2. The changes of loading on the TMJ according to antero-posterior positional changes of metal pivoting ball were able to recognize as follow. Compression on the TMJ was increased when the pivot moves anteriorly from the equilibrium point, and tension on the TMJ was increased when posteriorly. 3. 13 subjects were recognized their habitual chewing sides(Rights, Left8), and 7 subjects were not. During maximal biting, mandible was displaced toward their habitual chewing sides on the metal pivoting ball in the frontal plane. 4. In cephalometric analysis, the average genial angle of 20 subjects was $116.75^{\circ}$ and the average mandibular body length was 79.77mm. The equilibrium points of mandibular moment were positioned more posteriorly in the subjects having larger Genial angle than in the smaller(p<0.05). Relationships among the angle between FH plane and occlusal plane, the angle between occlusal plane and mandibular plane , and mandibular body length were not significant(p>0.05).

  • PDF

미식축구의 필드골(Field Goal) 킥(Kick)에 대한 운동학적 분석 (A three-dimensional kinematic analysis of the field goal kicking motion in American football)

  • 안찬규;김기형;최승방
    • 한국운동역학회지
    • /
    • 제13권1호
    • /
    • pp.139-153
    • /
    • 2003
  • The purpose of the study was to present technical guidance about the field goal kicking motion in American football for novices. For this purpose, kinematic analysis on the field goal kicking motion of two skilled players and two unskilled players was carried out. The following conclusions were made: 1. In comparison on the total elapsed time of the kicking, there were no significant differences between two groups. The progressing time from BP event to impact among experts group, however, took 0.141 second less than that of novices group. 2. The experts group showed right hip rotatier horizontally toward the targeted ball fixing left hip as the axis. On the other hand, the novices group didn't use the left hip as the axis in the kicking motion. 3. At the impact of kicking the ball, regarding with the distance of the ball and the supporting leg, the right and left distance of experts was 3.45cm longer than that of novices, the front and the rear distance of experts was 5.14cm shorter than novices. 4. At the impact, experts' initial velocity of the targeted ball was $5.27^m/s$ faster than novices', besides experts' incidence angular displacement was $3.78^{\circ}$ larger than novices'. 5. After BP event, experts showed a stable movement maintaining flexion and extension at left hip joint and knee joint. On the other hand, for novices, the angle of the left lower extremities became larger. 6. Experts showed the efficient flexion and extension of the hip joint and the knee joint during following procedure in the whole event of the kicking motion. At the BP event, the right knee joint angle of novices was $11.46^{\circ}$ larger than that of experts. However, the duration of the impact event and FT event among, novices had less extension of knee joint than experts. 7. At the 2nd phase, for both of the groups, the angular velocity of the knee joint drastically increased as the angular velocity of hip joint decreased. However, only novices showed the largest negative angular velocity at the impact.

Progression-Preserving Dimension Reduction for High-Dimensional Sensor Data Visualization

  • Yoon, Hyunjin;Shahabi, Cyrus;Winstein, Carolee J.;Jang, Jong-Hyun
    • ETRI Journal
    • /
    • 제35권5호
    • /
    • pp.911-914
    • /
    • 2013
  • This letter presents Progression-Preserving Projection, a dimension reduction technique that finds a linear projection that maps a high-dimensional sensor dataset into a two- or three-dimensional subspace with a particularly useful property for visual exploration. As a demonstration of its effectiveness as a visual exploration and diagnostic means, we empirically evaluate the proposed technique over a dataset acquired from our own virtual-reality-enhanced ball-intercepting training system designed to promote the upper extremity movement skills of individuals recovering from stroke-related hemiparesis.

인산망간 피막의 마찰 마모 특성에 관한 연구 , (A Study on Friction and Wear of Manganese Phosphate Thin Film)

  • 박영도;유상희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1384-1389
    • /
    • 2004
  • In these days, wear resistance is an essential condition because the relative movement between machine parts is being accelerated and those connected with the drive parts transmit power and force. Also wear resistance is closely related to reliability and life of products, therefore the study on friction and wear is very important in many fields. In this paper, wear test was conducted to know properties about friction and wear of manganese phosphate being used widely. Test type is 1 ball on disk and we compared manganese phosphate thin film with non-coated material. Through this study, we could know the effect of this surface treatment method, and then it is assumed that the reliability of parts will be secure.

  • PDF

피스톤 냉각용 오일제트 비정상 유동 해석 (Unsteady Flow Analysis of Oil Jet for Cooling the Piston)

  • 권지혁;이연원;김재환
    • 한국자동차공학회논문집
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2008
  • In order to enhance the performance of an automotive engine, many researchers have been carried out. An oil jet cooling a piston is one of important parts for engine performance. Therefore, the efficient cooling system of an oil jet is needed. In this paper, unsteady flow analysis of the oil jet which consists of a check valve and a nozzle has been accomplished. And the reaction between mass flow rate and ball movement was also investigated.

점진성형에서 알루미늄 판재의 성형성에 대한 연구 (A Study on Formability of Aluminum Sheet in Incremental Forming)

  • 박종진;김영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1142-1147
    • /
    • 2003
  • The formability of sheet metal appears better in incremental forming than in conventional forming. in this study, the effect of process parameters - tool type, tool size, feed rate, friction at the interface between tool and sheet, plane-anisotropy of sheet - on the formability was investigated by experiments and FEM analyses. it was found that the formability is improved when a ball tool of a particular size is used with a small feed rate and a little friction. Due to the plane anisotropy, the formability differs according to the direction of the tool movement. in this paper, details of the experimental procedures and the results obtained from the study are discussed.

  • PDF

사판식 유압모터의 특성실험 (I) (Characteristic Experiment of Swashplate Type Axial Piston Motor (I))

  • 염만오;윤일로
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.561-569
    • /
    • 2000
  • The purpose of this study is to construct a testing equipment with which several characteristics of the domestically developed swashplate type axial piston motor can be tested and to develop a software with which the data from experiment can be stored and can be applied. The results of the study are as follows; 1) The leakage flow and the torque of the motor being stopped is propotional to supply pressure and their relation can be showed by linear equations. 2) The motor movement is not smooth below 50 rpm but it moves smoothly up 170 rpm. 3) When the motor starts or stops, the pressure rise ratio effects decisively to the max. torque.

A Micro Tribotester for MEMS Elements

  • Kim Choong-Hyun;Ahn Hyo-Sok
    • 한국공작기계학회논문집
    • /
    • 제15권4호
    • /
    • pp.39-43
    • /
    • 2006
  • A computer-controlled micro tribotester has been developed to investigate the friction and wear characteristics of thin coatings, which can be applied to silicon-based materials. In the developed system, a step motor gives a reciprocating movement and an electromagnet applies a load between a ball and a plate specimen. Test results confirmed that the application of load in the range of $0.03{\sim}1.8N$ and with a sliding speed of $4.44{\sim}7.70mm/s$ was successfully accomplished. Advantages of the developed micro tribotester are: (1) realization of micro load and displacement applicable to micro electromechanical systems(MEMS) using DC motor and electromagnet (2) continuously variable load and reciprocating speed; and (3) high reliability, which allows for unattended use for long periods.

감속 스텝모터를 이용한 2축 인장·전단 시험기의 개발 (Development of Biaxial Tension & Shear Tester using Stepper Motor with Harmonic Driver)

  • 최병선;배원호;채영석
    • 한국산업융합학회 논문집
    • /
    • 제4권4호
    • /
    • pp.379-386
    • /
    • 2001
  • The lower toughness or brittle materials for mechanical test lead to the additional requirement that applied displacements be controlled with high resolution. Biaxial tension and shear tester using stepper motor with harmonic driver is shown. The device had to be high resolution so that the crack initiation process of slow extension and steady growth could be examined, Grip plates were connected to a linear bearing and actuator. The actuators consisted of stepper motors with harmonic driver connected to pre-loaded ball screw and nut assemblies. The encoders and motor controllers were connected to a personal computer so that arbitrary displacements histories could he prescribed in normal and tangential directions. The linear bearings were used to react loads perpendicular to their axes while allowing low friction, parallel movement of the attached grips. Load cells measured the reactions normal and tangential. the loads measured the reactions were recorded by the computer.

  • PDF

포인트 레이저 센서를 이용한 구면좌표계식 3차원 형상측정시스템 개발 (Development of 3D Measuring System using Spherical Coordinate Mechanism by Point Laser Sensor)

  • 맹희영;성봉현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.201-206
    • /
    • 2004
  • Laser scanner are getting used for inspection and reverse engineering in industry such as motors, electronic products, dies and molds. However, due to the lack of efficient scanning technique, the tasks become limited to the low accuracy purpose. The main reasons for this limitation for usefulness are caused from the optical drawback, such as irregular reflection, scanning direction normal to measuring surface, the influence of surface integrity, and other optical disturbances. To overcome these drawback of laser scanner, this study propose the mechanism to reduce the optical trouble by using the 2 kinds of rotational movement axis and by composing the spherical coordinate to scanning the surface keeping normal direction consistently. So, it could be designed and interfaced the measuring device to realize that mechanism, and then it could acquisite the accurate 3D form cloud data. Also, these data are compared with the standard master ball and the data acquisited from the touch point sensor, to evaluate the accuracy and stability of measurement and to demonstrate the implementation of an dental tooth purpose system

  • PDF