• Title/Summary/Keyword: Balanced-Unbalanced

Search Result 309, Processing Time 0.031 seconds

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

Safety Assessment of Human Body for the Electromagnetic Field of Unbalanced Power System (불평형 계통에서의 전자계에 대한 인체안전평가)

  • 김상철;송현선;김두현
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.54-62
    • /
    • 1999
  • This paper presents a study on the safety assessment of human body for electromagnetic field at unbalanced power system. The 3-phase load flow algorithm uses Newton-Raphson method based on Taylor series expansion of power flow equations in rectangular coordinates. The use of such a method can result in a solution with good convergence characteristics. In the safety assessment of human body, the approach based on fuzzy linguistic variable is employed to overcome the shortcomings resulting from a crisp set concept. The suggested scheme is applied to a 24bus system to validate the usefulness. The results for an unbalanced power system are compared with the results for a balanced power system.

  • PDF

Experimental Study on the Dynamic Balancing Method of an Unbalanced Rigid Rotor -Using Seven Run Method- (불평형 회전체의 동적평형 방법에 대한 실험적 연구 -Seven Run Method를 이용하여-)

  • Chang, Ho-Gyong;Choi, Hyun-Tai;Kim, Ye-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.48-55
    • /
    • 1991
  • In this study, the unbalanced rigid rotor mounted on two pedestals is balanced u. ng the dynamic balancing procedure, and the compensating masses are estimated by the seven run method. Also, the reductions of vibration level are examined, before and after balancing procedures. In the experimental results, it is shown that the vibration amplitudes measured at the two pedestals are proportional to the unbalanced mass. The seven run method which requires measurement of vibration amplitudes only and not vibration phase angle is proved markedly useful in consideration of the dynamic balancing procedure.

  • PDF

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

A Study on the MgO thin film prepared by Unbalanced Magnetron Sputtering in AC PDP (AC PDP의 불평형 마그네트론 스파트링에 의해 형성된 MgO 박막의 특성에 관한 연구)

  • 김영기;박정후;김영대;박정후;조정수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.379-382
    • /
    • 1999
  • In this paper, we investigated the characteristics of MgO thin film prepared by unbalanced magnetron sputtering(UBMS) in surface discharge type AC PDP The minimum discharge voltage is obtained for the sample of substrate bias voltage-10V. Moreover the anti-sputtering characteristics of MgO thin film by UBMS is improved about 40% than one of balanced magnetron sputtering(BMS)

  • PDF

A New Analysis for Load Unbalance Factor (부하 불평형율에 대한 새로운 해석)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.2
    • /
    • pp.67-72
    • /
    • 2006
  • Most of the load distributions in low voltage power feeder distribution systems are designed with approximately balanced and connected at the three phase four wire systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating load unbalance. Load unbalance factor is mainly affected by the impedance of load system. Unbalanced current will draw a highly unbalanced voltage. This paper presents a new calculation method for unbalance factor under the load variation at the three phase four wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared with the current unbalance factor. Two methods are indicated similar results.

Design and Characteristic Analysis of Moving Coil type Linear Oscillatory Actuator Considering Unbalanced Magnetic Circuit (불평형 자기회로를 고려한 가동 코일형 리니어 진동 엑추에이터의 설계 및 특성해석)

  • Kim, Duk-Hyun;Eum, Sang-Joon;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.403-410
    • /
    • 2000
  • This paper deals with a study to improve the performance of Moving Coil type Linear Oscillatory Actuator (MC-LOA) considering unbalanced magnetic circuit. MC-LOA has an unbalanced magnetic circuit due to its asymmetric structure. In this type of LOA, the airgap flux density tends to have different magnitude along mover's displacement and the current directions. The above property causes eccentric of displacement center and interferes with the proper oscillation of LOA. Therefore, this paper presents two models having the unbalanced magnetic circuit and the other balanced by the saturated core. In order to compare the characteristics between the two models, a characteristic analysis for both the basic model and the improved model is performed by their dynamic analysis composed of kinetic and electric equations and Finite Element Method (FEM). The propriety of the improved model is verified through the experimental results.

  • PDF

Design of a Hybrid Controller for the Three-phase Four-leg Voltage-source Inverter with Unbalanced Load

  • Doan, Van-Tuan;Kim, Ki-Young;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.181-189
    • /
    • 2017
  • The three-phase four-leg voltage-source inverter topology is an interesting option for the three-phase four-wire system. With an additional leg, this topology can achieve superior performance under unbalanced and nonlinear load conditions. However, because of the low bandwidth of conventional controllers in high-power inverter applications, the system cannot guarantee a balanced output voltage under the unbalanced load condition. Most of the methods proposed to solve this problem mainly use the multiple synchronous frame method, which requires several controllers and a large amount of computation because of frame transformation. This study proposes a simple hybrid controller that combines proportional-integral (PI) and resonant controllers in the synchronous frame synchronized with the positive-sequence component of the output voltage of the three-phase four-leg inverter. The design procedure for the controller and the theoretical analysis are presented. The performance of the proposed method is verified by the experimental results and compared with that of the conventional PI controller.

Analysis of Voltage Control of Stand-Alone Microgrid for High Quality Power Supply (고품질 전력공급을 위한 독립형 마이크로그리드의 전압제어 해석)

  • Jo, Jongmin;Lee, Hakju;Shin, Chang-hoon;Cha, Hanju
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.253-257
    • /
    • 2016
  • This paper analyzes voltage control method in order to supply high-quality power for stand-alone microgrid. Stand-alone microgrid is composed of battery bank, stand-alone PCS and controllable loads. The main role of stand-alone PCS is to supply high-quality power to loads as main source by using stable voltage method regardless of load conditions. In particularly, output voltage of stand-alone PCS gets severely unbalanced voltage under unbalanced loads. Fundamental positive and negative sequences are transformed by two coordinates transformation which are rotated in each opposite direction, respectively. Each fundamental d-q voltage is regulated by each fundamental PI control. In addition, low-order harmonics are compensated through resonant controllers. Performance of stand-alone microgrid is tested for feasibility, and it is verified that output voltage of THD is improved to 1% from 2.2% under 50 kW balanced load, and is improved to 1.1% from 2.6% under 50 kW unbalanced load.

Multi-objective Unbalanced Distribution Network Reconfiguration through Hybrid Heuristic Algorithm

  • Mahendran, G.;Sathiskumar, M.;Thiruvenkadam, S.;Lakshminarasimman, L.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.215-222
    • /
    • 2013
  • Electrical power distribution systems are critical links between the utility and customer. In general, power distribution systems have unbalanced feeders due to the unbalanced loading. The devices that dependent on balanced three phase supply are affected by the unbalanced feeders. This necessitates the balancing of feeders. The main objective of reconfiguration is to balance the loads among the phases subject to constraints such as load flow equations, capacity and voltage constraints and to reduce the real power loss, while subject to a radial network structure in which all loads must be energized. Therefore, the distribution system reconfiguration problem has been viewed as multi-objective problem. In this paper, the hybrid heuristic algorithm has been used for reconfiguration, which is the combination of fuzzy and greedy algorithms. The purpose of the introduction of greedy is to refrain the searching for the period of phase balancing. The incorporation of fuzzy helps to take up more objectives amid phase balancing in the searching. The effectiveness of the proposed method is demonstrated through modified IEEE 33 bus and modified IEEE 125 bus radial distribution system.