• 제목/요약/키워드: Balance System

검색결과 2,953건 처리시간 0.031초

The immediate effects of patellar taping on balance and gait ability in individuals with chronic stroke

  • Shin, Jin;Mun, Mee-Hyang;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • 제3권2호
    • /
    • pp.125-133
    • /
    • 2014
  • Objective: The aim of this study is to investigate the effect of patellar taping on balance and gait abilities in chronic stroke patients. Design: Randomized placebo-controlled trial. Methods: Thirty chronic stroke patients who have been diagnosed at least six months or before were recruited from R hospital. These study subjects were randomized to the experimental group (n=15) or placebo group (n=15). In the experimental group, patellar taping was applied while for the placebo group, placebo taping was applied. The Balance System SD was used for measuring dynamic standing balance in these two groups. In addition, the GAITRite (CIR System Inc.) system was utilized for calculating gait performance in these patients. Results: After application of taping, the patellar taping group showed a significant decrease in dynamic standing balance in their sway area (p<0.05). However, in the placebo group, there was no significant difference in dynamic standing balance ability and gait ability before and after application of taping. Comparison of the patellar taping group and placebo group showed significant differences in dynamic standing balance ability and gait performance (p<0.05). Conclusions: From the results of this study, it appears that application of patellar taping in chronic stroke patients significantly improved dynamic standing balance ability and gait ability in these patients. Based on these results, patellar taping is thought to be useful in real clinical settings where there are many chronic patients who are in need of improvement in their balance and gait ability.

PDP TV에서 인간 시각을 고려한 최적의 White Balance 구현 (A White Balance System for PDP TV)

  • 정기백;구본철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.363-366
    • /
    • 2003
  • We propose the system that automatically adjusts the white balance on display products to a standard value according to several nations. We replace manual or semi-auto method with fully automatic method using windows application program. And we use RS-232C serial interface to communicate PC with display products which we want to adjust white balance. The PC generates patterns for measuring color information and Color Analyzer measures color and brightness. This value is transmitted through RS-232C serial interface to PC. The PC's algorithm analyzes this information and then decides which RGB Gain value is best for optimal white balance. This RGB Gain value is transmitted through RS-232C serial interface to display products. The modified color value is measured again and feed back to PC. This sequence is repeated until optimum white balance is obtained.

  • PDF

기계식 타이머 밸런스 휠의 진동 주파수 측정 및 조정 장비의 개발 (Development of a oscillating frequency measurement and adjustment system of a balance wheel of Mechanical Timer)

  • 이돈진;박수범;안중환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.879-883
    • /
    • 2000
  • A system for measuring and adjusting the oscillating frequency of a balance wheel whick determins the accuracy of mechanical timers. The balance wheel oscillates rotatively suspended by a hair spring which is welded at the other end to the pivot tube. The natural oscillatory frequency of the balance wheel is determined by the length of hairspring from the balance wheel to the point if other parameters the length in the torsional oscillation model are not changed, so the frequency of the balance wheel can be adjusted to meet a requirement by the adjustment of the hairspring length using ultrasonic welding. And the movement of wheel teeth is measured in realtime by a high speed photo fiber sensor and Auto Correlation is used to find a more accurate oscillation period from the measured signal with some variations.

  • PDF

정적 및 동적 균형 수행력에 대한 임산부 여성의 변화 (The Changes of Static and Dynamic Balance Performance in Pregnancy Women)

  • 채윤원
    • The Journal of Korean Physical Therapy
    • /
    • 제20권1호
    • /
    • pp.17-22
    • /
    • 2008
  • Purpose: This study examined whether or not changes in the static and dynamic balance performance occur during pregnancy. Methods: Fourteen pregnant women and fourteen non-pregnant women volunteered to participate in the study. All subjects were tested for their balance performance on the Chattecx Balance System (Chattanooga Group, Inc., USA) under a two platform condition: stable platform and dynamic platform(forward-backward sliding and tilting). The Chattecx Balance System was measured using the postural sway index, anterior-posterior sway index, and medial-lateral sway index. Results: There was a significant difference in the postural sway index and anterior posterior sway index in the static and dynamic platform condition between the pregnant and non-pregnant women (p<0.05). However, there was no difference in the medial-lateral sway index. Conclusion: The postural sway index and anterior-posterior sway index decreases during pregnancy.

  • PDF

동적 힘 평형 모델을 이용한 GMA 용접의 용적이행 해석 (Analysis of Metal Transfer using Dynamic Force Balance Model in GMAW)

  • 최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • 제19권4호
    • /
    • pp.399-405
    • /
    • 2001
  • A dynamic force balance model is proposed in this work as an extension of the previous static force balance model to predict metal transfer in arc welding. Dynamics of a pendant drop is modeled as the second order system, which consists of the mass, spring and damper. The spring constant of a spherical drop at equilibrium is derived in the closed-form equation, and the inertia force caused by drop vibration is included in the drop detaching condition. While the inertia force is small in the low current range, it becomes larger than the gravitational force with current increase. The inertia force reaches half of the electromagnetic force at transition current, and has considerable effects on drop detachment. The proposed dynamic force balance model predicts the detaching drop size more accurately than the static force balance model.

  • PDF

드럼세탁기의 Weight Balance 최적설계

  • 조한기
    • 한국CDE학회지
    • /
    • 제2권2호
    • /
    • pp.52-54
    • /
    • 1996
  • 드럼세탁기에 있어서 weight는 세탁기의 진동 및 소음에 중요한 역할을 한다. 기존 pulsator 세탁기는 액체밸런스를 사용하여 세탁물의 편심을 상쇄시켜 세탁기의 진동을 억제시키지만, 드럼세탁기는 주물이나 시멘트 등을 weight balance로 사용하고, 세탁기 구동부의 무게, damping system 등과의 상호작용으로 세탁기의 진동을 억제시킨다. 본 연구에서는 Ideas-Design의 Master Molder와 Assembly을 사용하여 드럼세탁기의 weight balance을 설계한다. 이와 같이 weight balance는 드럼진동 및 소음 뿐만 아니라 세탁기의 전체 무게에도 매우 큰 영향을 미친다.

  • PDF

3차원 동적 운동기기를 이용한 4주간의 운동 시 균형 능력에 미치는 효과 (Effect on the Balance Ability after Four Week Training Using the System for 3-D Dynamic Exercise Equipment)

  • 신선혜;유미;정구영;유창호;김경;정호춘;권대규
    • 재활복지공학회논문지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 2012
  • 기존의 3차원 동적 운동기기를 통한 연구는 체간 안정화 운동에 주목하였으나, 본 연구에서는 이러한 연구들이 자세균형에 미치는 영향을 평가하고자 하였다. 훈련에 참여한 피험자는 요부와 하지 근육에 이상이 없는 20대 남녀 24명을 대상으로 하였으며, 체간 안정화 및 자세균형 훈련은 주 3회 15분씩 4주간에 걸쳐 진행되었다. 자세균형능력평가는 Balance System SD을 이용하였으며, 20초 동안 신체의 중심이 흔들리지 않고 한 점에 유지하는 능력인 자세 안정성 검사와 8가지 방향으로의 이동능력 평가인 자세 한계성 검사로 이루어졌다. 연구 결과 3차원 동적 운동기기를 이용한 4주간의 훈련이 자세균형 향상에 도움을 주었으며, 이는 3차원 동적 운동기기를 낙상 위험이 높은 고령자나 자세균형 훈련이 필요한 운동선수들에게 적용하기 위한 기초자료로써 활용될 수 있을 것이나 예상된다.

  • PDF

햅틱 장치를 이용한 균형 훈련 시스템 및 효용성 검증 (A Balance Training System using a Haptic Device and Its Evaluations)

  • 윤정원;라힐 아프잘;표상훈;오민균
    • 제어로봇시스템학회논문지
    • /
    • 제20권9호
    • /
    • pp.971-976
    • /
    • 2014
  • Haptic device can be a useful rehabilitation tool in balance training. The proposed system is composed of a body-wear smartphone, Phantom Omni(R) device, and its control PC system. Ten young healthy subjects performed balance tasks with different postures during 30 seconds with their eyes closed. An Android program on the smartphone transferred mediolateral (ML) and anteroposterior (AP) tilt angles to the PC system, which can generate haptic command through haptic device. Statistical data analysis was performed using MATLAB(R). COP (Center of Pressure) related indexes were measured to see reduction in body sway. ANOVA showed that haptic device significantly reduced body sway. Intuitive balance guidance could be generated using an economical and small-sized commercial haptic device, making the system efficient.

자세균형제어 시스템의 개발 (Development of Postural Balance Control System)

  • 양길태;김영호;임송학;장윤희;문무성
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.276-279
    • /
    • 1997
  • A simple bio-feedback system was developed to monitor and to analyze patient's postural balance. Two load celIs were used to measure the weight of each side. A specially designed electronic circuit was made to pick up the weight signals and to feed into the data acquisition system. Clinical trials were also made on 20-30 year-old normal subjects and nine hemiplegia patients who had the potential instability in weight bearing. A Microsoft window-based software collected and analyzed the postural balance data. Normal subjects showed only 5% deviations of their body weight. However, hemipegic patients had significant weight shifts toward the healthy limb. With the present system, patients can also exercise their balance and weight bearing. The present system should be of convenience to monitor in real-time and analyze the postural balance control of hemiplegic patients.

  • PDF