• Title/Summary/Keyword: Bag filter

Search Result 162, Processing Time 0.027 seconds

A study on the optimization design of pulse air jet system to improve bag-filter performance (여과집진기의 탈진 성능 향상을 위한 충격 기류 분사 시스템 최적화 설계에 관한 연구)

  • Hong, Sung-Gil;Jung, Yu-Jin;Park, Ki-Woo;Jeong, Moon-Heon;Lim, Ki-Hyuk;Suh, Hye-Min;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3792-3799
    • /
    • 2012
  • The dedusting characteristics of pulse air jet type dedusting system which is widely applied in the industries were identified by utilizing the computational fluid dynamics (CFD) and the dedusting performance in modified shape of dedusting unit was compared in this study. The review on the dedusting air volume, air stream distribution and inflow velocity distribution on each shape of dedusting part showed that the case of installing the nozzle on the blow tube (Case-3) and the case of installing the double intaking tube to the venturi (Case-4 and Case-5) were more excellent than the structure (Case-1) which is widely applied in the field in its amplification effect on the air volume and extension of stream width. The specification of venturi was decided to apply the selected Case-5 for the option of the commercial back filter. It is considered that the dedusting air volume will be maintained in maximum in the case of 50 mm and 90 mm for the diameter of internal and external intaking pipe respectively.

Dust Removal Efficiency and Operation Characteristics of Metal Filters for Coal Gasification Fines and Standard Dust Sample (금속필터를 사용한 석탄가스화 분진 및 표준 분진의 집진 효율과 운전특성)

  • Yun, Yongseung;Chung, Seok Woo;Lee, Seung Jong
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.461-468
    • /
    • 2019
  • Demand for improving dust removal efficiency in coal power plants and the dust removal requirement to the level of capturing fine particulate matter and ultrafine particles have been increasing. While bag filter and electrostatic precipitator (ESP) are typically used for dust removal in the processes operating at atmospheric pressure, metal filters or ceramic filters are employed for dust which is produced at high temperature/pressure system as in coal gasification. For dust removal at the high temperature/pressure conditions, two metal filters of five compressed/sintered layers were manufactured and applied to analyze the dust removal characteristics. Manufactured metal filters exhibited more than 99% dust removal efficiency on coal gasification fine particulates in mass basis. To evaluate the fine particulate removal efficiency of less than $2.5{\mu}m$, JIS standard fine sample was used and confirmed the removal efficiencies of 97% and 70~82% on the fine particulates of $1{\sim}2.5{\mu}m$ size range. For the size range of less than $1{\mu}m$, dust removal efficiency of manufactured metal filters significantly degraded with smaller particle size. Improving methods are proposed to overcome the limitations in applying to fine dust of less than $1{\mu}m$.

Development of the Electrolysis Ballast Water Treatment System and Test (직접 전기분해식 선박평형수 처리장치 개발과 시험에 관한 연구)

  • Bag, Og-Yeol;Moon, Jang;Park, Jun-Mo;Kong, Gil-Young
    • Journal of Navigation and Port Research
    • /
    • v.41 no.3
    • /
    • pp.79-86
    • /
    • 2017
  • Ballast water filled into and discharged from the ballast tank of a ship has a negative impact on local marine environment due to various aquatic organisms contained therein. The IMO developed and adopted "The International Convention for the Control and Management of Ships Ballast Water and Sediments, 2004" with the purpose of protecting the marine environment from transfer of harmful aquatic organisms in ballast water carried by ships. The IMO BWM Convention was approved in September 2016 and ships must be equipped with ballast water management system after September 2017. Ships' ballast water treatment methods are divided into using active substances as electrolytic type, ozone type, chemical dosing type and using physical treatment type as filter type, ultraviolet type. It is also used with a combination of two methods. Electrolysis is superior in terms of cost and efficiency. In this study, basic principles, components, and land base test contents of electrolysis ballast water treatment system, a direct electrolyzed ballast water treatment system, were examined. Land base test was conducted with 300m3/h capacity device at the KIOST Geoje plant where the government test facility was installed. This test validated that the system meets IMO standards.

Development of Low Temperature Thermal Desorption System and Remediation of Soil Contaminated with Petroleum Hydrocarbon (열순환식 저온열탈착 정화장치의 개발 및 유류오염 토양 현장 적용)

  • Kim, Guk-Jin;Lee, Sun-Hwa;Park, Kwang-Jin;Kim, Chi-Kyung;Lee, Cheol-Hyo;Kim, Do-Sun;Cho, Seok-Hee;Chang, Youn-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.4
    • /
    • pp.62-68
    • /
    • 2008
  • The Low Temperature Thermal Desorption (LTTD) System equipped with a soil transfer unit, a rotary kiln, RTO, cyclones and a bag filter etc. was developed. The LTTD system was designed to be economically operated using LPG as a fuel and recirculating the discharged gas from the LTTD system through RTO. For the performance test of LTTD system the soil contaminated with light and heavy oils (2,690 mg TPH/kg soil) and with particle sizes below 50 mm was fed into the rotary kiln of LTTD system at 7$m^3$/hr with retention time of 15 minutes. Operation temperatures of LTTD system for the removal of soil TPH were $567^{\circ}C$ and $692^{\circ}C$. The residual TPH after treatment was 46 mg/kg and 32mg/kg respectively at each temperature condition, which shows high TPH removal efficiencies of the developed LTTD as 98.3% and 98.9%.

Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble (나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가)

  • Lee, Hyung-Don;Lee, Seung-Hwan;Park, Chan-gyu
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • Air pollutants in a subway are complexly caused by outdoor factors such as ventilating opening and indoor factors such as the movement of passengers on the subway. According to recent research results, most of the air pollutants generated in subway tunnels and stations are caused by indoor variables such as train movement. To control air pollutants such as particulate matter (PM), a prevention facility such as the electrostatic precipitator (EP) or bag filter collector was required in a subway station. In particular, the PM removed by the EP must be kept clean continuously to manage PM effectively. Therefore, a nano-bubbling washing system was developed in this study to clean a contaminated collecting plate in an EP at the main subway tunnel in Seoul. Removal efficiency compared with normal water and nano-bubbling water was likewise studied. As a result, the washing efficiency of collective PM increased in accordance with the increasing of injection pressure, with nano bubbling washing being 130.8% higher than tap water. According to increase in washing times, the maximum washing efficiency was 143.1% higher than tap water, but suitable washing times were less than 3 times. According to the results of the washing efficiency by variation of residence time, it was confirmed that the maximum residence time of nano-bubble water was maintained within 5 minutes.

Use-friendly Active Packaging of Powdered Infant Formula in Single-serve Portion Augmented with Anti-oxidative Function (산화억제 가능성과 사용편의성을 가진 일회성 조제분유 포장)

  • Lee, Hye Lim;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.95-99
    • /
    • 2019
  • In the modified atmosphere packaging of powdered infant formula, the oxygen inside the package may cause its quality deterioration and needs to be minimized for quality preservation. A way of oxygen scavenger inclusion in the single-serve package without contacting the product was devised for removing oxygen residing initially and permeating through the seal layer during the storage. A polyethylene/pulp multi-layer porous filter bag of 5 × 7 cm containing 13 g of powdered infant formula was packaged in an 8 × 9 cm size aluminium laminated film package with a Fe-based oxygen scavenger of 1.8 g. After nitrogen flushed packaging, the active packages were stored at 30℃ for 254 days with periodical quality measurement. The active package could remove the initial residual oxygen of 1.4% completely and maintain absence of oxygen for the whole storage, which contributed to reduced oxidation observed in lower product peroxide value compared to that of the product in the control package. There was no influence of packaging treatment on content of 5-hydroxymethylfurfural, reaction product of initial nonenzymatic browning. The devised oxygen-scavenging single-serve package showed a potential to improve the preservation of infant formula powder and extend the shelf life.

Environmental impact evaluation and improvement measure of incineration plant by life cycle assessment (전과정평가를 이용한 소각시설의 환경영향평가 및 개선방안)

  • Kim, Hyeong-Woo;Kim, Kyeong-Ho;Park, Hung-Suck
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.4
    • /
    • pp.88-100
    • /
    • 2013
  • This study evaluated the direct and indirect environmental impacts of various unit operations of a industrial waste incineration plant by using the life cycle assessment tool and reviewed the improvement plan. During the incineration process, the direct environmental impact was decreased with decrease in emission of various air pollutants by incorporating an air pollution prevention facilities. However, an increase in indirect environmental impacts was observed as a consequence of resources and energy of consumption at the various operational facilities. Consequently, quantitative direct and indirect impact were 89.1%, 10.9%, respectively. The environmental impact analysis of system revealed the highest impact of incineration followed by the impacts of other unit processes such as semidry reactor, and bag-filter. The various air pollutants and ashes generated during the incineration process caused the most significant environmental impact. Among the various categories of environmental impact, global warming accounted the highest impact(more than 85%) followed by eutrophication, and abiotic depletion. As a result of the avoided impact by the utilization of heat generated during the waste incineration process, using an incineration heat for steam and electricity obtained the impact reduction of 45.5%, 19.8%. So, during siting of new incineration plant, the utilization of steam generated from the waste combustion is highly considered to reduce the environmental impact.

A review of analytical method for volatile fatty acids as designated offensive odorants in Korea (악취성 유기지방산 성분의 분석기술)

  • Ahn, Ji-Won;Kim, Yong-Hyun;Kim, Ki-Hyun;Song, Hee-Nam
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.91-101
    • /
    • 2012
  • A list of volatile fatty acids (VFA) including propionic acid, butyric acid, isovaleric acid, valeric acid, etc. is well known for offensive odorants. The analysis of odorant VFA is a highly delicate task due to high reactivity and unstable recovery rate. At present, analytical methods of VFA are recommended to include alkali impregnation filter method and alkali absorption method by the malodor prevention law of the Korea Ministry of Environment (KMOE). In this review, a survey has been made to explore various approaches available for the analysis of VFA to include both official methods of the KMOE and others. In light of the unreliability of those established analytical methods, it is highly desirable to develop some substituting methods for VFA. Among such options, one may consider such option as sorbent tube (ST) sampling and cryogenic trapping-thermal desorption technique. Moreover, procedures used for standard preparation, sampling steps, and instrumental detection stage are also evaluated. Application of container sampling (like Tedlar bag) is however not recommendable due to significant (sorptive) loss in sampling and in storage stage. In the detection stage, the use of GC/MS is recommendable to replace GC/FID due to the presence of diverse interfering substances. Thus, it is essential to properly establish the basic quality assurance (QA) for VFA analysis in air.

A Study on the Emission and Dispersion of Particulate Matter from a Cement Plant (한 시멘트공장의 분진발생과 대기확산에 관한 조사연구)

  • Chang, Man-Ik;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.67-77
    • /
    • 1983
  • To investigate the an air pollution by particulate matter and its dispersion, a cement plant produceing portland cement 600,000 ton/year and its vicinity were surveyed from Obtober, 1980 to April, 1983. The survey was mainly focused on main stack emmission rate of the cement plant and particle size distribution in the dust, dustfall and total suspended particulate concentration in the area by month and distance from the stack. The results of the study were as follows; 1. The main stack emission rate was surveyed before and after the spray tower was additionally installed to the original E.P bag filter. Before the spray tower installed, the main stack emission rate was higher ($0.64g/Nm^3$) than the emission standard of Korean Environmental Preservation Law's ($0.59g/Nm^3$, amended to $0.4g/Nm^3$ on April 1983), but after the spray tower was installed, its main stack emission rate was markedly decreased to the standard ($0.43g/Nm^3$). 2. $2{\sim}3{\mu}m$ of the particle size was the largest portion (20.8%) of the dust particulate from the main stack and 50% of the frequency distribution was $1.5{\mu}m$ of the size. Most particle size was below $10{\mu}m$. 3. The spray tower reduced the dustfall to $37.81{\sim}9.76\;ton/km^2/month$ while dustfall appeared at $45.29-15.45ton/km^2/month$, in the vicinity of plant before spray tower installed 4. Mean concentrations of total suspended particulate for 24 hours of the various stations were determined in $20.6-200.0{\mu}g/m^3$, 3 stations of tham were higher than the value of Harry and William's arthmetic average standard $130{\mu}g/m^3$. 5. Linear regression between dustfall [X] and total suspended particulate[Y] concentration was an equation, Y=4.024X+11.479.[r=0.91] 6. During the whole seasons in the opposite area 100m apart from the omission source the prevailing wind direction was with estimated more than $30ton/km^2/month$, and the concentration of total suspended particulate for 24 hours averaging time was more than $140{\mu}g/m^3$ in the same area and direction. 7. Assuming the wind direction were constant through the day dustfalls for a day were estimated at $13.40ton/km^2/day,\;10.79ton/km^2/day$ and $4.55ton/km^2/day$ at various distances of 100m, 500m and 1,500m from the emission source respectively. 8. In the simutalion of dustfall and suspended dust by area, Gaussian dispersion model modified by size distribution of particulate matter was not applicated since the emission of dust were from multi sources other them stack. From the above results, it could be applied that the dispersion of dust from the cement plant is estimated and regulated for the purpose of environmental protection.

  • PDF

Effect of Collection Times of Rumen Fluid on In vitro Dry Matter Digestibility of Forage Crops (반추위액 채취 시간이 사료작물의 In vitro 건물 소화율에 미치는 영향)

  • Jo, Nam-Chul;Jung, Min-Woong;Kim, Meing-Jung;Lim, Young-Chul;Yook, Wan-Bang
    • Journal of Animal Environmental Science
    • /
    • v.15 no.2
    • /
    • pp.91-98
    • /
    • 2009
  • Object of this study were to determine the influence of collection times of rumen fluid on in vitro dry matter digestibility (IVDMD) of forage crops. The donor cow was fed concentrate once a day and given free access to grass-legume mixture hay. Main plot was consisted of different collection time of rumen fluid; T1: 1 hour before concentrate feeding, T2: 1 hour after feeding, T3: 4 hour after feeding and T4: 8 hour after feeding. A total of 7 samples of 4 different forage crops (barely, Italian ryegrass, crimson clover, rye) were used for the estimation of IVDMD and tested in three replicates. For the $DAISY^{II}$ incubation, each sample was inserted into each filter bag then heat-sealed and incubated in a digestion vessel for 48 h at $39^{\circ}C$. The times of rumen fluid collection had no significant effect on the IVDMD values over all varieties except for 2 breeds of IRG (Kogreen and Kospeed). IVDMD values with T1 over all varieties were slightly higher than other treatments, however those with both T1 of Kogreen and Kospeed varieties were significantly higher than T2 (p<.05).

  • PDF