• Title/Summary/Keyword: Backscattered X-ray

Search Result 18, Processing Time 0.027 seconds

Development of Data Acquisition System using the Backscattered X-ray (후방산란성 엑스레이를 이용한 데이터 획득 시스템 개발)

  • Hwang, In-Ho;Jung, Jin-Seok;Yuk, Sun-Woo;Yoo, Sun-Kook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.10
    • /
    • pp.129-133
    • /
    • 2009
  • Considerable attention has been focused on digital X-ray systems with transmission. However, only a few attempts have been made using X-ray backscatter systems. This study developed a Data Acquisition System (DAS) for backscattered X-rays. The imaging system used X-ray backscatter at low energy levels, which has unique advantages in terms of acquiring information that cannot be obtained using the transmission system. Such systems are of potential benefit in the medical, industrial, security and military fields because of its practical benefits and the low doses used. The developed system is a similar body scan system. Experiments were carried out using a several metal materials and a fish, which produces results similar to those obtained using the human body during X-ray testing.

Analysis of Heat Generation Induced by Electron Impact in X-Ray Tube Using FEM and Monte Carlo Method (유한요소법과 몬테카를로법을 이용한 X선 튜브에서 전자빔 충격에 의한 열 발생 해석)

  • Kim, Heungbae;Yoo, Tae Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.4
    • /
    • pp.387-394
    • /
    • 2015
  • We analyze heat generation as well as temperature distribution induced by accelerated electron impact on a target in a closed x-ray tube. For the sake of accuracy, we use Monte carlo analysis. This method gives accurate energy deposit in a medium with additional information such as secondary and backscattered electron as well as their paths. A Tungsten coated layer is divided by small rectangular cell which accumulate energy loss of primary electron beam. The cells and their accumulated energy datum are used for the input of finite element analysis. The Maximum temperature rising and temperature distribution were analyzed by transient heat analysis. Some temperature parameters such as target size and coating thickness were varied to investigate temperature sensitivity. Temperatures were compared each other to find primary variable that affect temperature rising on the x-ray target. The results will be helpful in development highresolution x-ray tube and related industries.

A way Analyzing Oxide Layer on an Irradiated CANDU-PHWR Pressure Tube Using an EPMA and X-ray Image Mapping

  • Jung, Yang Hong;Kim, Hee Moon
    • Corrosion Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.118-128
    • /
    • 2021
  • The oxide layer in samples taken from an irradiated Zr-2.5Nb pressure tube from a CANDU-PHWR reactor was analyzed using electron probe microanalysis (EPMA). The examined tube had been exposed to temperatures ranging from 264 to 306 ℃ and a neutron fluence of 8.9 × 1021 n/cm2 (E > 1 MeV) for the maximum 10 effective full-power years in a nuclear power plant. Measuring oxide layer thickness generally employs optical microscopy. However, in this study, analysis of the oxide layer from the irradiated pressure tube components was undertaken through X-ray image mapping obtained using EPMA. The oxide layer characteristics were analyzed by X-ray image mapping with 256 × 256 pixels using EPMA. In addition, the slope of the oxide layer was measured for each location. A particular advantage of this study was that backscattered electrons and X-ray image mapping were obtained at a magnification of 9,000 when 20 kV volts and 30 uA of current were applied to radiation-shielded EPMA. The results of this study should usefully contribute to the study of the oxide layer properties of various types of metallic materials irradiated by high radiation in nuclear power plants.

Microstructural analysis of the single crystalline AlN and the effect of the annealing on the crystalline quality (단결정 AlN의 미세구조 분석 및 어닐링 공정이 결정성에 미치는 영향)

  • Kim, Jeoung Woon;Bae, Si-Young;Jeong, Seong-Min;Kang, Seung-Min;Kang, Sung;Kim, Cheol-Jin
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.28 no.4
    • /
    • pp.152-158
    • /
    • 2018
  • PVT (Physical Vapor Transport) method has advantages in producing high quality, large scale wafers where many researches are being carried out to commercialize nitride semiconductors. However, complex process variables cause various defects when it had non-equilibrium growth conditions. Annealing process after crystal growth has been widely used to enhance the crystallinity. It is important to set appropriate temperature, pressure, and annealing time to improve crystallinity effectively. In this study, the effect of the annealing conditions on the crystalline structure variation of the AlN single crystal grown by PVT method was investigated with synchrotron whitebeam X-ray topography, electron backscattered diffraction (EBSD), and Rietveld refinement. X-ray topography analysis showed secondary phases, sub-grains, impurities including carbon inclusion in the single crystal before annealing. EBSD analyses identified that sub-grains with slightly tilted basal plane appeared and the overall number of grains increased after the annealing process. Rietveld refinement showed that the stress caused by the temperature gradient during the annealing process between top and bottom in the hot zone not only causes distortion of grains but also changes the lattice constant.

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage

  • Kim, Noh-Yu;Achenbach, J.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.6
    • /
    • pp.417-426
    • /
    • 2006
  • A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also introduced to overcome distortion of the Compton backscatter data due to attenuation effects attributed to beam hardening and quantum noise.

Measurements of X-Ray Production Cross-Sections for 0.5¡­1.2-MeV Proton Beam (0.5~l.2-MeV 양성자빔에 대한 X-선 발생단면적의 측정)

  • Hae-ill BAK;Jun-Gyo BAK
    • Nuclear Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.108-115
    • /
    • 1990
  • The measurements of X-ray production cross-sections for 0.5~1.2-MeV proton beam are carried out on Cu and Au. For this experiment, the proton tram generated from the SNU 1.5-MV Tandem Van do Graaff accelerator is Incident on the target. The X-rays and the backscattered protons from the irradiated target are detected simultaneously by the Si(Li) X-ray detector and the SSB (Silicone Surface Barrier) charged particle detector The measured values of X-ray production cross-sections are compared with other experimental values and theoretical values such as the PWBA (Plane Wave Born Approximation) and the ECPSSR(Perturbed Stationary State corrected Energy loss, Coulomb deflection, Relativistic effects) values. For measured cross-sections near 1.0- MeV proton energy, the ECPSSR (D.D. Cohenet al., 1985) shows better agreement than the PWBA. Particularly, that of Au for 1.2 MeV proton beam is 9.69$\pm$ 0.39 barns which deviates from the ECPSSR by less than 5%. and the experimental data for 0.5~1.2- MeV proton agree with most of other experimental values within 30%.

  • PDF

Uranium Particle Identification with SEM-EDX for Isotopic Analysis by Secondary Ion Mass Spectrometry

  • Esaka, Fumitaka;Magara, Masaaki
    • Mass Spectrometry Letters
    • /
    • v.7 no.2
    • /
    • pp.41-44
    • /
    • 2016
  • Secondary ion mass spectrometry (SIMS) is a promising tool to measure isotope ratios of individual uranium particles in environmental samples for nuclear safeguards. However, the analysis requires prior identification of a small number of uranium particles that coexist with a large number of other particles without uranium. In the present study, this identification was performed by scanning electron microscopy - energy dispersive X-ray analysis with automated particle search mode. The analytical results for an environmental sample taken at a nuclear facility indicated that the observation of backscattered electron images with × 1000 magnification was appropriate to efficiently identify uranium particles. Lower magnification (less than × 500) made it difficult to detect smaller particles of approximately 1 μm diameter. After identification, each particle was manipulated and transferred for subsequent isotope ratio analysis by SIMS. Consequently, the isotope ratios of individual uranium particles were successfully determined without any molecular ion interference. It was demonstrated that the proposed technique provides a powerful tool to measure individual particles not only for nuclear safeguards but also for environmental sciences.

A STUDY ON THE MICROSTRUCTURES OF THE AMALGAM ALLOYS AND AMALGAMS (치과용 아말감합금 및 아말감의 마세구조에 관한 연구)

  • Yeon, Sang-Heum;Lee, Chung-Sik;Lee, Myung-Jong;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.87-105
    • /
    • 1996
  • The purpose of this study is to investigate the characteristics of the compositions and phases of amalgam alloys and amalgams by using EMPA and X-ray diffractometer. Each specimen was made from Caulk Fine Cut Clow copper lathe cut amalgam), Caulk Spherical (low copper spherical amalgam), Tytin (high copper unicorn position amalgam), Dispersally (high copper admixed amalgam) and Valiant (Palladium enriched amalgam). For preparing amalgam alloys, Tytin and Valiant were used as powder forms and the others were used as tablet forms after being polished with polishing machine. For preparing amalgams, each amalgam alloy and Hg were measured, and triturated by mechanical amalgamater according to user's instructions. After triturating, the triturated mass was inserted to cylindrical metal mold and simultaneously adapted by cylindrical condenser with same diameter and condensed by Instron universal testing machine with 80kg pressure & 1mm/min speed. Each specimen was removed from the metal mold and stored at room temperature for a week. The specimen was polished with the same polishing machine for amalgam alloy. For observation of microstructure and analysis of composition of amalgam alloys and amalgams, EMPA was used to get secondary electron images, backscattered images and characteristic X-ray images of Ag, Sn, Cu, Zn, Hg. To analyze compositions of amalgam alloys and amalgams, X-ray diffractometer was used. Amalgam alloys were scanned at the range of 2${\theta}$ of 30-$85^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line and amalgams were scanned at the range of 2${\theta}$ of 28-$44^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line. By comparing obtained d(distance between surfaces) and d of expected phases and atoms in amalgam alloys and amalgams in ASTM card, phases and atoms were identified. The results were as follows, 1. In Caulk Fine Cut amalgam alloy typical ${\gamma}$ phase was shown, and in amalgam, ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phases were observed. 2. In Caulk Spherical amalgam alloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, ${\gamma}_2$ and $\eta$ phases were observed. 3. In Tytin amalgam alloy ${\gamma}$, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 4. In Dispersalloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 5. In Valiant alloy ${\gamma}$, Cu and e phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed.

  • PDF

Feasibility Study for the Development of a Device for Detecting Pathological Tissues (병리학적 조직 진단장치 개발에 대한 타당성 분석 연구)

  • Ko, Chea-Ok;Park, Min-Young;Pack, Jeong-Ki
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.421-424
    • /
    • 2005
  • X-ray is currently most effective method in detecting small malignant breast tumors but has the several problems due to suppressing breast, ionizing radiation and not detecting small cancer. In this paper, a new method is proposed by using dielectric characteristics of pathological tissues and time delay of backscattered response. We have developed a detection algorithm and verified it by numerical simulation and measurement for a prototype system. For a prototype system, we have fabricated experimental model(artificial breast with a cancer) and UWB(ultra-wideband) antenna. The results of the measurement simulation show an excellent detection capability of a cancer tissue. It is found that a good UWB antenna is a key element of such detection system. Further study is ongoing to develop a commercial system.

  • PDF