• Title/Summary/Keyword: BI Rate

Search Result 567, Processing Time 0.023 seconds

FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube (평균 양방향 튜브의 설계 최적화를 위한 FLUENT 코드해석)

  • Kang, Kyong-Ho;Yun, Byong-Jo;Euh, Dong-Jin;Baek, Won-Pil
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.4 s.31
    • /
    • pp.14-19
    • /
    • 2005
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the average bi-directional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the average bi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

Interlaboratory Comparison of Critical Current Measurements on Ag-sheathed Bi-2223 tapes (Bi-2223선재의 임계전류 측정기술 비교)

  • Lee, Kyu-Won;Han, Gi-Youl
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.99-103
    • /
    • 2001
  • We have conducted two runs of interlaboratory comparison on Ag-sheathed Bi-2223 tapes to evaluate the level of measurement techniques for the critical current measurement. Two classes of specimens were prepared for parallel and serial routings and sent to four participating laboratories. The critical currents of specimens were measured at 77 K in zero magnetic field. In the first comparison, we used twenty different Bi-2223 tapes as specimens for comparison and participating laboratories measured the specimens using their own instruments and procedures. As a result, the scattering of data on the first comparison showed -3.0% to +l2.2% for the parallel routing and -0.7% to +l5.1% for the serial routing. Major sources of these variations were attributed to different measurement techniques. Thus, the second comparison of measurement was done on the same specimens under specified measurement conditions, particularly in terms of cooling procedure and sweep rate of the test current. The variations for the second comparison were decreased -3.1% to +3.2% far the parallel routing and -1.8% to +7.7% fur the serial routing.

  • PDF

Controlling the initial conditions of precursor powders and its effects on the phase evolution and $J_c$ properties of Bi-2223/Ag tapes

  • Jiang, C.H;Yoo, J.M;Kim, H.D;Kang, S.C;Chung, H.S;Wang, Y.Z;Ko, J.W;Qiao, G.W
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.91-94
    • /
    • 2001
  • By varying fabricating process, precursor powders with different initial conditions were prepared. Subsequently, Bi-2223/Ag tapes were made through these powders. The effects of precursor powders on the phase evolution and Jr properties of Bi-2223/Ag tapes were studied along with several thermomechanical cycles. Our results showed that the initial conditions of precursor powders could strongly influence the phase formation rate and $J_{c}$ value in final tapes. The factors of precursor powders that influence the phase formation and $J_{c}$ of Bi-2223/Ag tapes must be studied and optimized in combination.ion.

  • PDF

A Study on the Thermal Properties and Plasma Resistance of Bi2O3-Al2O3-SiO2 Glass (Bi2O3-Al2O3-SiO2 유리의 열물성과 내플라즈마 특성 연구)

  • Young Min Byun;Jae Ho Choi;Won Bin Im;Hyeong Jun Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.64-71
    • /
    • 2023
  • In this study, we investigated the effects of BiAlSiO glass composition on its glass forming range, thermal properties, and plasma resistance. The results showed that increasing the Al2O3 content suppressed the tendency for crystallization and hindered glass formation beyond a certain threshold. Bi2O3 was found to increase the content of non-bridging oxygen, resulting in a decrease in glass transition temperature and an increase in thermal expansion coefficient. Furthermore, the etching rate was found to improve with increasing Al2O3 content but decrease with increasing SiO2 content. It was concluded that the boiling point of fluorinated compounds should be considered to 900℃. Therefore, this study is expected to contribute to the understanding of the properties of BiAlSiO glass and its application to low temperature melting PRG compositions.

  • PDF

A Study on BI's Plan to Achieve the Performance of Start-up Companies (BI의 창업기업 성과달성 방안에 관한 연구)

  • Hwang, Kyoo-il
    • Journal of Venture Innovation
    • /
    • v.5 no.1
    • /
    • pp.75-90
    • /
    • 2022
  • Start-up is a very important task for the development of the country as well as individuals for entrepreneurs with novel ideas, experiences, and know-how. Most of the new start-ups often have no start-up experience, and the government and universities operate start-up incubator centers so that start-up companies can grow and develop. The goal is to improve the success rate of technology-based start-ups. It supports various needs of start-up companies and supports start-up companies to succeed by enabling them to maximize their potential. The expected effect of the start-up incubator center can be said to be a contribution to the development of the national economy through the revitalization of start-ups. This study aims to consider ways to achieve performance through the efficient operation of domestic start-up incubator centers.

An Improvement on Multicode CDMA Systems Using a Convolutional Code and a Bi-Orthogonal Code (길쌈 부호와 이원 직교 부호에 의한 다중부호 부호분할 다원접속 시스템의 개선)

  • 김기범;신요안
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.7
    • /
    • pp.1659-1666
    • /
    • 1998
  • The multicode CDMA systems that are widely studied as an effective transmission methodology in the IMT-2000 systems, employ orthogonal codes to transform high rate data into parallel, low rate data for simultaneous transmission. In this paper, we propose a new multicode CDMA system which achieves the same data rate and processing gain of the conventional systems, while significantly improves bit error rate performance by exploiting a convolutional code with code rate r=1/2 and a bi-orthogonal code. The simulation results for synchronous systems using maximal ratio combining Rake receivers under additive white Gaussian noise and multi-path fading channels, show significant improviements by the proposed system.

  • PDF

Performance of the Cold Latent Storage System (냉열잠열축열조의 성능해석)

  • Yoon, Ho Sik;Ro, Sung Tack
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.456-465
    • /
    • 1988
  • The performance of the cold latent heat storage is investigated by experiment and by a simplified analytic approach. The heat storage tank has eight horizontal circular tubes and one path of refrigerant evaporating tube. The phase change material in the heat storage tank is water which is frozen by evaporating refrigerant of refrigeration system and melts by the warm air in the heat storage tank. In the experiment, the performance has been studied by the various conditions including the initial water temperature on solidification and flow rate and temperature of air. The rate of recovered heat has been simulated by a simplified model and the results shows a good agreement. In solidification process, initial water temperature causes time delay corresponding to the sensible heat and it is found that the shape of evaporator is important. In melting process, the recovered heat rate from the heat storage tank is proportional to $Re^{0.8}(T_{bi}-T_f)$ of air where $T_{bi}$ and $T_f$ indicate temperatures of inlet air and phase change, respectively. And the deminishing rate of the recovered heat is higher for the higher heat rate.

  • PDF

The Effect of Nasal BiPAP Ventilation in Acute Exacerbation of Chronic Obstructive Airway Disease (만성 기도폐쇄환자에서 급성 호흡 부전시 BiPAP 환기법의 치료 효과)

  • Cho, Young-Bok;Kim, Ki-Beom;Lee, Hak-Jun;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.190-200
    • /
    • 1996
  • Background : Mechanical ventilation constitutes the last therapeutic method for acute respiratory failure when oxygen therapy and medical treatment fail to improve the respiratory status of the patient. This invasive ventilation, classically administered by endotracheal intubation or by tracheostomy, is associated with significant mortality and morbidity. Consequently, any less invasive method able to avoid the use of endotracheal ventilation would appear to be useful in high risk patient. Over recent years, the efficacy of nasal mask ventilation has been demonstrated in the treatment of chronic restrictive respiratory failure, particularly in patients with neuromuscular diseases. More recently, this method has been successfully used in the treatment of acute respiratory failure due to parenchymal disease. Method : We assessed the efficacy of Bilevel positive airway pressure(BiPAP) in the treatment of acute exacerbation of chronic obstructive pulmonary disease(COPD). This study prospectively evaluated the clinical effectiveness of a treatment schedule with positive pressure ventilation via nasal mask(Respironics BiPAP device) in 22 patients with acute exacerbations of COPD. Eleven patients with acute exacerbations of COPD were treated with nasal pressure support ventilation delivered via a nasal ventilatory support system plus standard treatment for 3 consecutive days. An additional 11 control patients were treated only with standard treatment. The standard treatment consisted of medical and oxygen therapy. The nasal BiPAP was delivered by a pressure support ventilator in spontaneous timed mode and at an inspiratory positive airway pressure $6-8cmH_2O$ and an expiratory positive airway pressure $3-4cmH_2O$. Patients were evaluated with physical examination(respiratory rate), modified Borg scale and arterial blood gas before and after the acute therapeutic intervention. Results : Pretreatment and after 3 days of treatment, mean $PaO_2$ was 56.3mmHg and 79.1mmHg (p<0.05) in BiPAP group and 56.9mmHg and 70.2mmHg (p<0.05) in conventional treatment (CT) group and $PaCO_2$ was 63.9mmHg and 56.9mmHg (p<0.05) in BiPAP group and 53mmHg and 52.8mmHg in CT group respectively. pH was 7.36 and 7.41 (p<0.05) in BiPAP group and 7.37 and 7.38 in cr group respectively. Pretreatment and after treatment, mean respiratory rate was 28 and 23 beats/min in BiPAP group and 25 and 20 beats/min in CT group respectively. Borg scale was 7.6 and 4.7 in BiPAP group and 6.4 and 3.8 in CT group respectively. There were significant differences between the two groups in changes of mean $PaO_2$, $PaCO_2$ and pH respectively. Conclusion: We conclude that short-term nasal pressure-support ventilation delivered via nasal BiPAP in the treatment of acute exacerbation of COPD, is an efficient mode of assisted ventilation for improving blood gas values and dyspnea sensation and may reduce the need for endotracheal intubation with mechanical ventilation.

  • PDF

A Discussion on the Terms Related to ratio and rate from the Revised 2007 Curriculum textbook (초등학교 2007 개정 교과서 비와 비율 관련 용어에 대한 고찰)

  • Hong, Gap Ju
    • Journal of Educational Research in Mathematics
    • /
    • v.23 no.2
    • /
    • pp.285-295
    • /
    • 2013
  • In this study I examine the definitions of terms related to ratio and rate from 5, 6, 7th revised elementary school math textbooks to discuss the improvements and the remained problems in 2007 curriculum textbook. Next, I make the alternative definitions of the terms, 'biyoul', the value of 'bi', and 'baekboonyul' by re-establishing the relations between them. Finally, I point out that those problems are intrinsic to the attempt of the textbook to introduce the terms related to ratio with little consideration for the mathematical meaning of ratio as a equivalence class.

  • PDF

Analysis of the Hi-system Superconducting Thin Films Fabricated by Layer-by-Layer Deposition Method at an Ultra low growth rate (초 저속 순차증착으로 제작한 Bi계 초전도 박막의 생성막 평가)

  • Yang, Seung-Ho;Kim, Young-Pyo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.503-504
    • /
    • 2007
  • $Bi_2Sr_2Ca_{n-1}Cu_nO_x$(n=0, 1, 2)superconducting thin films have been fabricated by atomic layer-by-layer deposition at an ultra low growth rate using IBS(Ion Beam Sputtering) method. During the deposition, 90 mol% ozone gas of typical pressure of $1{\sim}9{\times}10^{-5}$ Torr are supplied with ultraviolet light irradiation for oxidation. XRD and RHEED investigations reveal out that a buffer layer with some different compositions is formed at the early deposition stage of less than 10 units cell and then Bi-2201 oriented along the c-axis is grown.

  • PDF