• Title/Summary/Keyword: B-unit

Search Result 2,521, Processing Time 0.026 seconds

Overexpression, Purification, and Preliminary X-Ray Crystallographic Studies of Methionine Sulfoxide Reductase B from Bacillus subtilis

  • Park, Ae-Kyung;Shin, Youn-Jae;Moon, Jin-Ho;Kim, Young-Kwan;Hwang, Kwang-Yeon;Chi, Young-Min
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.59-62
    • /
    • 2008
  • The peptide methionine sulfoxide reductases (Msrs) are enzymes that catalyze the reduction of methionine sulfoxide back to methionine. Because of two enantiomers of methionine sulfoxide (S and R forms), this reduction reaction is carried out by two structurally unrelated classes of enzymes, MsrA (E.C. 1.8.4.11) and MsrB (E.C. 1.8.4.12). Whereas MsrA has been well characterized structurally and functionally, little information on MsrB is available. The recombinant MsrB from Bacillus subtilis has been purified and crystallized by the hanging-drop vapor-diffusion method, and the functional and structural features of MsrB have been elucidated. The crystals belong to the trigonal space group P3, with unit-cell parameters a=b=136.096, $c=61.918{\AA}$, and diffracted to $2.5{\AA}$ resolution using a synchrotron-radiation source at Pohang Light Source. The asymmetric unit contains six subunits of MsrB with a crystal volume per protein mass $(V_M)\;of\;3.37{\AA}^3\;Da^{-1}$ and a solvent content of 63.5%.

A Study on Wired LogiC for Type Unit for PLC Output Driving (PLC 출력 구동을 위한 Wired Logic for Type Unit에 관한 연구)

  • 위성동;김태성
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.51-57
    • /
    • 1999
  • This thesis is written about the Wired Logic Type Unit in developing equipment that the load is driven, that the interface unit connect with 1 Scan time to PO30 of operated PLC output contact with that a sensing signal of Temperature Sensor RSD Pt $100\Omega$ let generate the relay output of temperature controller and input the PLC. The PLC Test Kit in country that the PLC to be programmed at the PLC education place is able to drive the load, is done to do a education of PLC on status that interface process between PLC and load are disregarded. As Developing Kit for supplement this point, when the relay output of temperature controller to use Pt 100 of temperature sensor as mentioned on the former among every kinds of sensor feed back to the input of the PLC, as the equipment to act with real time system that the output contact of PLC operated to insert the WLTIJ among PC, PLC and the load, it can understand and see very easy the main principle of PLC use. The structure of WLTU to be a interface unit of load separated as to the point of contact and noncontact, sensor, indicating lamp and A contact and B contact that is belong to driving part, and a motor is belong to loading part.

  • PDF

Chylomicron Retention Disease: a Description of a New Mutation in a Very Rare Disease

  • Ferreira, Helena;Ramos, Raquel Nunez;Quan, Cinthia Flores;Ferreiro, Susana Redecillas;Ruiz, Vanessa Cabello;Goni, Javi Juamperez;Bernabeu, Jesus Quintero;Canton, Oscar Segarra;Beltran, Marina Alvarez
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.2
    • /
    • pp.134-140
    • /
    • 2018
  • Chylomicron retention disease, also known as Anderson's disease, is a rare hereditary hypocholesterolemic disorder, recessive inherited, characterized by nonspecific symptoms as abdominal distension, steatorrhea, and vomiting associated with failure to thrive. We describe a patient with failure to thrive, chronic diarrhea and steatorrhea who the diagnosis of chylomicron retention disease was established after several months of disease progression. The genetic study confirmed a homozygosity mutation in SAR1B gene, identifying a mutation never previous described [c.83_84delTG(p.Leu28Argfs*7)]. With this case report the authors aim to highlight for this very rare cause of failure to thrive and for the importance of an attempting diagnosis, in order to start adequate management with low fat diet supplemented with fat-soluble vitamins, reverting the state of malnutrition and avoiding possible irreversible and desvantating complications.

EXISTENCE OF GROP INVARIANT SOULTIONS OF A SEMILINEAR ELLIPTIC EQUATION

  • Kajinkiya, Ryuji
    • Journal of the Korean Mathematical Society
    • /
    • v.37 no.5
    • /
    • pp.763-777
    • /
    • 2000
  • We investigate the existence of group invariant solutions of the Emden-Fowler equation, - u=$\mid$x$\mid$$\sigma$$\mid$u$\mid$p-1u in B, u=0 on B and u(gx)=u(x) in B for g G. Here B is the unit ball in n 2, 1$\sigma$ 0 and G is a closed subgrop of the orthogonal group. A soultion of the problem is called a G in variant solution. We prove that there exists a G invariant non-radial solution if and only if G is not transitive on the unit sphere.

  • PDF

A CHARACTERIZATION OF THE UNIT GROUP IN ℤ[T×C2]

  • Bilgin, Tevfik;Kusmus, Omer;Low, Richard M.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.53 no.4
    • /
    • pp.1105-1112
    • /
    • 2016
  • Describing the group of units $U({\mathbb{Z}}G)$ of the integral group ring ${\mathbb{Z}}G$, for a finite group G, is a classical and open problem. In this note, we show that $$U_1({\mathbb{Z}}[T{\times}C_2]){\sim_=}[F_{97}{\rtimes}F_5]{\rtimes}[T{\times}C_2]$$, where $T={\langle}a,b:a^6=1,a^3=b^2,ba=a^5b{\rangle}$ and $F_{97}$, $F_5$ are free groups of ranks 97 and 5, respectively.

Algorithm for the Implementation of Network Interface Unit Transmitter in Broadband Wireless Local Loop (광대역 무선 가입자망(B-WLL)에서 가입자용 송신기 구현 알고리즘)

  • 최승남;황호선;김대진
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.41-44
    • /
    • 1999
  • In this paper we proposed the algorithm for the implementation of network interface unit transmitter and analyzed its performance in broadband wireless local loop. The symbol rate of upstream transmitter is variable since the channel bandwidth of upstream can vary. Assuming that master clock ( $f_{DAC}$) is fixed, the cubic interpolator of Farrow structure is used to increase the sample rate to master clock rate. Simulation shows that the signal to noise ratio is about 54~55 dB and spurious signal power of upstream transmitter is less than 45 dB.B.

  • PDF

Load analysis for transporting unit module (유닛모듈 운반시 작용하중 분석)

  • Kim, Kyoon-tai;Jun, Young-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.200-201
    • /
    • 2015
  • The unit modular method is one in which unit modules are prefabricated at a factory and then constructed at a construction site. That is why an important process, transporting unit module, is added in this method. The purpose of this study is to analyse the load for transporting unit module. The results of the analysis of the driving experimental runs revealed that a maximum load of 15 kN was applied on adapter block type A and a maximum load of 25 kN on adapter block type B. These loads were recorded at the points in the road test when the low-bed trailer was driving through unstable sections of the test such as stopping, restarting, passing over a speed bump or taking a left turn at speed.

  • PDF

A Comparative Analysis of the Kinetic Structure in Lectures on a High School Science (고등학교 공통 과학 강의에서 교사에 따른 역동적 구조의 정량적 비교 분석)

  • Yu, Seung-Geun;Lee, Joon-Sang
    • Journal of The Korean Association For Science Education
    • /
    • v.20 no.4
    • /
    • pp.505-509
    • /
    • 2000
  • The kinetic structure of the content of instructions at the unit of 'heart and circulation' in "the common science", which was respectively given by two teachers majored in biology and two teachers majored in earth science was investigated. Concerning of the mean of the fundamental coefficient (B1), the mean of weighted coefficients (B2) and the progression of instruction (P), T4 (B1, 0.14; B2, 0.82; P; 0.86) teacher showed relatively lower kinetic structure and faster progression than those of the others. The other teachers showed a different level of the kinetic structure and progression: T1(B1, 0.21; B2, 0.86; P; 0.79), T2 (B1, 0.02; B2, 0.85; P; 0.80), and T3 (B1, 0.22; B2, 0.83; P; 0.78). T1 teacher who showed the largest total frequency of verbal elements, the great number of sorts of verbal elements and secondary span, had a higher level of the kinetic structure, but T4 teacher showed the lowest level of total frequency of verbal elements, the great number of sorts of verbal elements and secondary span. The main reason why T4 teacher's instruction achieved a lower level of kinetic structure was estimated that he neglected to reorganize teaching materials and he showed a small number of discourse units. In addition, the unit of 'heart and circulation' was less related to T4 teacher's major and T4 teacher had a shorter teaching experience than those of the others. T4 teacher also took charge of only one class, and this did not allow to instruct repeatedly.

  • PDF