• Title/Summary/Keyword: B-Scan

Search Result 417, Processing Time 0.025 seconds

Preliminary Results of 3-Dimensional Conformal Radiotherapy for Primary Unresectable Hepatocellular Carcinoma (절제 불가능한 원발성 간암의 입체조형 방사선치료의 초기 임상 결과)

  • Keum Ki Chang;Park Hee Chul;Seong Jinsil;Chang Sei Kyoung;Han Kwang Hyub;Chon Chae Yoon;Moon Young Myoung;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.123-129
    • /
    • 2002
  • Purpose : The purpose of this study 띤as to determine the potential role of three-dimensional conformal radiotherapy (3D-CRT) in the treatment of primary unresectable hepatocellular carcinoma. The preliminary results on the efficacy and the toxicity of 3D-CRT are reported. Materials and Methods : Seventeen patients were enrolled in this study, which was conducted prospectively from January 1995 to June 1997. The exclusion criteria included the presence of extrahepatic metastasis, liver cirrhosis of Child-Pugh classification C, tumors occupying more than two thirds of the entire liver, and a performance status of more than 3 on the ECOG scale. Two patients were treated with radiotherapy only while the remaining 15 were treated with combined transcatheter arterial chemoembolization. Radiotherapy was given to the field including the tumor plus a 1.5 cm margin using a 3D-CRT technique. The radiation dose ranged from $36\~60\;Gy$ (median; 59.4 Gy). Tumor response was based on a radiological examination such as the CT scan, MR imaging, and hepatic artery angiography at $4\~8$ weeks following the completion of treatment. The acute and subacute toxicities were monitored. Results : An objective response was observed in 11 out of 17 patients, giving a response rate of $64.7\%$. The actuarial survival rate at 2 years was $21.2\%$ from the start of radiotherapy (median survival; 19 months). Six patients developed a distant metastasis consisting of a lung metastasis in 5 patients and bone metastasis in one. The complications related to 30-CRT were gastro-duodenitis $(\geq\;grade\;2)$ in 2 patients. There were no treatment related deaths and radiation induced hepatitis. Conclusion : The preliminary results show that 3D-CRT is a reliable and effective treatment modality for primary unresectable hepatocellular carcinoma compared to other conventional modalities. Further studies to evaluate the definitive role of the 3D-CRT technique in the treatment of primary unresectable hepatocellular carcinoma are needed.

A Study on Integrated Visualization and Mapping Techniques using the Geophysical Results of the Coastal Area of the Dokdo in the East Sea (독도 연안 해저 지구물리 자료의 통합 중첩 주제도 작성 연구)

  • Lee, Myoung Hoon;Kim, Chang Hwan;Park, Chan Hong;Rho, Hyun Soo;Kim, Dae Choul
    • Economic and Environmental Geology
    • /
    • v.49 no.5
    • /
    • pp.381-388
    • /
    • 2016
  • The purpose of this study is to integrate and visualize using mapping techniques based on precise seabed geomorphology, seafloor backscattering images and high-resolution underwater images of the nearshore area around the Dokdo, in the East Sea. We have been obtained the precise topography map using multibeam echosounder system around the nearshore area(~50 m) of the southern part of the Seodo. Side scan sonar survey for analysis seafloor backscattering images was carried out in the same area of topography data. High-resolution underwater images(zone(a), zone(b), zone(c)) were taken in significant habitat scope of the nearshore area of the southern part of the Seodo. Using the results of bathymetry, seafloor backscattering images, high-resolution underwater images, we performed an integrated visualization about the nearshore area of the Dokdo. The integrated visualizing techniques are possible to make the seabed characteristic mapping results of the nearshore area of the Dokdo. The integrated visualization results present more complex and reliable information than separate geological products for seabed environmental mapping study and it is useful to understand the relation between seafloor characteristics and topographic environments of the study area. The integrated visualizing techniques and mapping analysis need to study sustainably and periodically, for effective monitoring of the nearshore ecosystem of the Dokdo.

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

Review of the Radiation Risk and Clinical Efficacy Associated with Computed Tomography Cancer Screening (암의 조기발견을 위한 CT촬영에서의 임상적 효능과 방사선위해에 대한 고찰)

  • Kim, Hyun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.214-227
    • /
    • 2013
  • Computed tomographic scan as a screening procedures in asymptomatic individuals has seen a steady increase with the introduction of multiple-raw detector CT scanners. This report provides a brief review of the current controversy surrounding CT cancer screening, with a focus on the radiation induced cancer risks and clinical efficacy. 1. A large study of patients at high risk of lung cancer(the National Lung Screening Trial[NLST]) showed that CT screening reduced cancer deaths by 20%(1.33% in those screened compared with 1.67% in those not screened). The rate of positive screening tests was 24.2% and 96.4% of the positive screening results in the low-dose CT group were false-positive. Radiation induced lung cancer risk was estimated the most important in screening population because ERR of radiation induced lung cancer does not show the decrease with increasing age and synergistic connection between smoking and radiation risk. Therefore, the radiation risk may be on the same order of magnitude as the benefit observed in the NLST. Optimal screening strategy remain uncertain, CT lung cancer screening is not yet ready for implementation. 2. Computed tomographic colonography is as good as colonoscopy for detecting colon cancer and is almost as good as colonoscopy for detecting advanced adenomas, but significantly less sensitive and specific for smaller lesions and disadvantageous for subsequent therapeutic optical colonoscopy if polyps are detected. The average effective dose from CT colonography was estimated 8-10 $mS{\nu}$, which could be a significant dose if administered routinely within the population over many years. CT colonography should a) achieve at least 90% sensitivity and specificity in the size category from 6 and 10 mm, b) offer non-cathartic bowl preparation and c) be optimized and standardized CT parameters if it is to be used for mass screening. 3. There is little evidence that demonstrates, for whole-body scanning, the benefit outweighs the detriment. This test found large portion of patient(86~90.8%) had at least one abnormal finding, whereas only 2% were estimated to have clinically significant disease. Annual scans from ages 45 to 75 years would accrue an estimated lifetime cancer mortality risk of 1.9%. There is no group within the medical community that recommends whole-body CT. No good studies indicate the accuracy of screening CT, at this time. The benefit/risk balance for any of the commonly suggested CT screening techniques has yet to be established. These areas need further research. Therefore wild screening should be avoided.

Clinical Characteristics of Pulmonary Aspergilloma (폐국균종의 임상적 고찰)

  • Kang, Tae-Kyung;Kim, Chang-Ho;Park, Jae-Yong;Jung, Tae-Hoon;Sohn, Jeong-Ho;Lee, Jun-Ho;Han, Seong-Beom;Jeon, Young-Jun;Kim, Ki-Beom;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo;Shin, Hyeon-Soo;Lee, Sang-Chae;Kweon, Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1308-1317
    • /
    • 1997
  • Background : Pulmonary aspergillomas usually arise from colonization and proliferation of Aspergillus in preexisting cavitary lung disease of any cause. About 15% of patients with tuberculous pulmonary cavities were found to have aspergilloma. We analyzed the clinical features and course of 91 patients with pulmonary aspergilloma. Method : During the ten-year period from June 1986 to May 1996, 91 patients whose condition was diagnosed as pulmonary aspergilloma at 4 university hospitals in Taegu city were reviewed. All patients fulfilled one of the following criteria : 1) histologic evidence of aspergilloma within abnormal air space in tissue sections, or 2) a positive Aspergillus serum precipitin test with the radiologic finding of a fungus ball. The histological diagno-sis was established in 81 patients(89.0%) and clinical diagnosis in 10 patients(11.0%). Results : 1) The age range was 22 to 65 years, with an average of 45 years. A male and female ratio was 1.7 : 1 (57 men and 34 women). 2) Hemoptysis was far the most frequent symptom(89%), followed by cough, dyspnea, weakness, weight loss, fever, chest pain. 3) In all but 14 cases(15.4%) there had been associated conditions. Pulmonary tuberculosis was far the most frequent underlying condition found(74.7%), followed by bronchiectasis (6.6%), cavitary neoplasm(2.2%), pulmonary sequestration(1.1%). 4) The involved area was usually in the upper lobes; the right upper lobe was involved in 39(42.9%), the left upper lobe in 31(34.1%), the left lower lobe in 13(14.3%), the right lower lobe in 7(7.7%), and the right middle lobe in 1(1.1%). 5) On standard chest roent geno gram the classic "bell-like" image of a fungus ball was found in 62.6% of the subjects. On CT scan, 88.1% of the subjects in which they were done. 6) The surgical therapy was undertaken in 76 patients, and medical therapy in 15 patients, including 4 patients with intracavitary instillation of amphotericin B. 7) The surgical modality was lobectomy in 55 patients(72.4%), segmentectomy in 16 patients(21.1%), pneumonectomy in 4 patients(5.3%), wedge resection in 1 patient(1.3%). The mortality rate was 3.9% (3 patients) ; 2 patients died of sepsis and 1 died of hemoptysis. The postoperative complications were encountered in 6 patients (7.9%), including each one patient with respiratory failure, bleeding, bronchopleural fistula, empyema, and vocal cord paralysis. 8) In the follow-up cases, each 2 patients of 71 patients with surgical treatment and 10 patients with medical treatment had recurrent hemoptysis. Conclusion : During follow-up of the chronic pulmonary disease with abnormal air space, if the standard chest roentgenograms are insufficient to detect a fungus ball, computed tomographic scan and serum precipitin test are likely to aid the diagnosis of patients with suspected pulmonary aspergilloma. A reasonable recommendation for management of a patient with aspergilloma would be to reserve surgical resection for those patients who have had severe, recurrent hemoptysis. And a well controlled cooperative study to the medical treatment such as intracavitary antifungal therapy is further needed.

  • PDF

Dose Response Relationship in Local Radiotherapy for Hepatocellular Carcinoma (원발성 간암의 국소 방사선치료 시 선량반응 관계)

  • Park Hee Chul;Seong Jinsil;Han Kwang Hyub;Chon Chae Yoon;Moon Young Myoung;Song Jae Seok;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.118-126
    • /
    • 2001
  • Purpose : In this study, it was investigated whether dose response relation existed or not in local radiotherapy for primary hepatocellular carcinoma. Materials and Methods : From January 1992 to March 2000, 158 patients were included in present study. Exclusion criteria included the presence of extrahepatic metastasis, liver cirrhosis of Child's class C, tumors occupying more than two thirds of the entire liver, and performance status on the ECOG scale of more than 3. Radiotherapy was given to the field including tumor with generous margin using 6, 10-MV X-ray. Mean tumor dose was $48.2{\pm}7.9\;Gy$ in daily 1.8 Gy fractions. Tumor response was based on diagnostic radiologic examinations such as CT scan, MR imaging, hepatic artery angiography at $4\~8$ weeks following completion of treatment. Statistical analysis was done to investigate the existence of dose response relationship of local radiotherapy when it was applied to the treatment of primary hepatocellular carcinoma. Results : An objective response was observed in 106 of 158 patients, giving a response rate of $67.1\%$. Statistical analysis revealed that total dose was the most significant factor in relation to tumor response when local radiotherapy was applied to the treatment of primary hepatocellular carcinoma. Only $29.2\%$ showed objective response in patients treated with dose less than 40 Gy, while $68.6\%\;and\;77.1\%$ showed major response in patients with $40\~50\;Gy$ and more than 50 Gy, respectively. Child-Pugh classification was significant factor in the development of ascites, overt radiation induced liver disease and gastroenteritis. Radiation dose was an important factor for development of radiation induced gastroduodenal ulcer. Conclusion : Present study showed the existence of dose response relationship in local radiotherapy for primary hepatocellular carcinoma. Only radiotherapy dose was a significant factor to predict the objective response. Further study is required to predict the maximal tolerance dose in consideration of liver function and non-irradiated liver volume.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.