• Title/Summary/Keyword: Axis extraction

Search Result 126, Processing Time 0.021 seconds

3D Stereoscopic Terrain Extraction of Road Cut Failure Slope Using Unmanned Helicopter Photography System (무인 헬리콥터 사진촬영시스템을 이용한 도로 절개지 붕괴사면 3차원 입체 지형 추출)

  • Jang, Ho-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.5
    • /
    • pp.485-491
    • /
    • 2010
  • Acquisition of information on failure slope, which may cause apprehension of second hand damage, requires acquisition of fast and accurate topographical data and efficient expression in indirect surveying method without accessing as needed. Therefore, in this study, the images on the intended area were photographed through hovering in the air by approaching collapsed road cut slope with the use of unmanned helicopter photography system. As a result of comparing the points observed by no prism total station and the 10 coordinate points analyzed through image analysis, the averages of absolute values were shown to be 0.056m in X axis direction, 0.082m in Y axis direction and 0.066m Z axis direction. In addition, the RMSE of the error for 10 points of test points were 0.015636m in X axis direction, 0.021319m in Y axis direction and 0.018734m in Z axis direction. Therefore, this method can determine the range of slope and longitudinal and cross sections of each slope in dangerous area that cannot be approached in relational image matching method for the terrains of such collapsed cut slope.

A Study on Evaluation Construct Model Extraction of Building Exterior Lighting applying Media Facade and Image Evaluation (미디어파사드를 적용한 건축외관조명의 평가구조 추출 및 이미지 평가에 관한 연구)

  • Kim, Seong Hui;Park, Ji-Yung;Lee, Jin-Sook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.1-12
    • /
    • 2015
  • In this study, we derive an evaluation structure and 18 Valuation vocabulary for the media facade lighting conditions. In addition, this study deduced the applicable elements that could be applied in time of building nightscape lighting design using media facade by conducting affective evaluation. The research results are as follows: It was found that the image axis of "Dynamic, Colorful" showed the lighting change speed was fast with diverse application of lighting color, and its evaluation object applied by general emphasis, vertical emphasis, partial emphasis lighting method was highly assessed. In addition, it was found that "Luxurious, Unusual" axis showed lighting change speed was slow with the application of lighting color in warm hue series, and its evaluation object applied by line lighting, dot lighting, general emphasis lighting methods was highly assessed. Lastly, it was found that "Soft, Secure" image axis showed the lighting change speed was slow with the application of pastel tone lighting color, and the evaluation object applied by general emphasis lighting method was highly assessed.

Structural analysis of horizontal axis wind turbine blade

  • Tenguria, Nitin;Mittal, N.D.;Ahmed, Siraj
    • Wind and Structures
    • /
    • v.16 no.3
    • /
    • pp.241-248
    • /
    • 2013
  • The wind turbine blade is a very important part of the rotor. Extraction of energy from wind depends on the design of blade. In this work, the analysis is done on a blade of length 38.95 m which is designed for V82-1.65 MW horizontal axis wind turbine (supplied by Vestas). The airfoil taken for the blade is NACA 634-221 which is same from root to tip. The analysis of designed blade is done in flap-wise loading. Two shapes of the spar are taken, one of them is of square shape and the other one is combination of square and cross shape. The blade and spar are of the same composite material. The Finite element analysis of designed blade is done in ANSYS. This work is focused on the two segments of blade, root segment and transition segment. Result obtained from ANSYS is compared with the experimental work.

Efficient and Exact Extraction of the Object Wave in Off-axis Digital Holography

  • Jang, Jin;Jeon, Jun Woo;Kim, Jin Sub;Joo, Ki-Nam
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.547-553
    • /
    • 2018
  • In this paper, a new method for spatial filtering in digital holography is proposed and verified by simulations compared to conventional methods. The new method is based on the simultaneous acquisition of two digital holograms, which can be separated by distinct spatial modulation, in a single image. Two holograms are generated by two reference waves, which have different spatial modulation orientations. Then, the overlapping region between the DC term and the object wave in the first hologram can be replaced with a less-overlapping region of the object wave in the second hologram because the whole image contains two holograms where the same objective wave has been recorded. In the simulation results, it is confirmed that the reconstructed image by the new method has better quality than for the original method.

Vision-Based Real-Time Motion Capture System

  • Kim, Tae-Ho;Jo, Kang-Hyun;Yoon, Yeo-Hong;Kang, Hyun-Duk;Kim, Dae-Nyeon;Kim, Se-Yoon;Lee, In-Ho;Park, Chang-Jun;Leem Nan-Hee;Kim, Sung-Een
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.171.5-171
    • /
    • 2001
  • Information that is acquired by adhered sensors on a body has been commonly used for the three-dimensional real-time motion capture algorithm. This paper describes realtime motion capture algorithm using computer vision. In a real-time image sequence, human body silhouette is extracted use a background subtraction between background image and the reference image. Then a human standing posture whether forward or backward is estimated by extraction of skin region in the silhoutte. After then, the principal axis is calculated in the torso and the face region is estimated on the principal axis. Feature points, which are essential condition to track the human gesture, are obtained ...

  • PDF

TREATMENT OF INVERTED MAXILLARY INCISOR (Inverted Maxillary Incisor의 치료)

  • Shin, Soo-Jeong;Chang, Young-In;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.23 no.1 s.40
    • /
    • pp.137-145
    • /
    • 1993
  • Inverted maxillary incisor is that maxillary incisor rotates to the counterclockwise direction. The incisal margin and root apex of the impacted incisor is palpated at the mucobuccal fold near the labial frenum and on the palate among the rugae, respectively. Orthodontists confront ectopically erupting teeth in various locations. In the past, extraction of impacted teeth that deviated from their normal course of eruption had been performed indiscriminately. But, if it has not any clearcut contraindications, effeort should be made to achieve optimal esthetic results by conservative means, combining the skills of oral surgeon and orthodontist. The present report provides an illustration of satisfactory correction of a inverted maxillary incisor with surgical intervention and many springs that correct the tooth axis. This technique provides the clinician with an additional means to avoid unnecessary extraction of inverted teeth in certain cases.

  • PDF

A Study On Automatic Background Extraction and Updating Method (자동 배경 영상 추출 및 갱신 방법에 관한 연구)

  • 김덕래;하동문;김용득
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.35-38
    • /
    • 2003
  • In this paper, I propose an automatic background extraction method and continuous background updating technique. Because there is a movement of a vehicle and a change of a background is feeble, the area moving through the time axis is looked for and a background and a vehicle image is divided. A way to give dynamically the threshold which divides the image frame into a vehicle image and the background in a space is enforced. Through the repetition of the above-mentioned process, the background pictorial image is gained. Using the karlman filter technique, the update is done so that a background image can obey a climate situation and an environmental change in day and night. A background image processed algorithm is better than the existent one. Through simulation, the feasibility of the algorithm has been verified.

  • PDF

Design of Pipeline Processor for ECG Feature Extraction (ECG 특징추출을 위한 파이프라인 프로세서의 설계)

  • 이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 1988
  • This paper describes the design of a hardware systenl for ECG feature extraction based on pipeline processor consistinsf of three microcomputers. ECG data is acquisited by 12 bit A/D converter with hardware QRS triggered detector. Four diagnostic parameters parameters-heart rate, morPhology, axis, and 57 segment-are used for the classification and the diagnosis of arrhythmia. The functions of the main CPU were distributed and processed with three microcomputers. Therefore the effective data process and the real time process using microcomputer can be obtained. The interconnection structure consisting of two common memory units is designed to decrease the delay time caused by data transfer between processors and designed by which the delay time can be taken Loye of one clock period.

  • PDF

A CASE REPORT OF AMELOBLASTOMA OF THE MANDIBLE (하악골에 발생한 Ameloblastoma의 증례)

  • Kim, Suk-Hwan
    • The Journal of the Korean dental association
    • /
    • v.16 no.4 s.107
    • /
    • pp.279-282
    • /
    • 1978
  • A girl aged 16 years and I month, had a severe Angle's class III malocclusion, characterized by a retarded and constricted maxilla, anterior and posterior crossbite. This patient underwent extraction of two lower Ist premolar. After extraction, author placed multibanded system in lower dental arch to change the long axis of anterior teeth and delivered removable appliance with Coffin spring in the upper dental arch to expand dental arch. After 13 months, anterior & posterior crossbite was corrected and this patient's profile was improved. Superimposition of pretreatment and posttreatment cephalograms upon the SN line registered at S showed backward downward rotation of the mandible and retrusion of lower lip.

  • PDF

A CASE REPORT OF SEVERE ANGLE'S CLASS III MALOCCLUSION (심한 Angle씨 III급 부정교합의 치험예)

  • Sung, Jae-Hyun
    • The Journal of the Korean dental association
    • /
    • v.16 no.4 s.107
    • /
    • pp.273-278
    • /
    • 1978
  • A girl aged 16 years and I month, had a severe Angle's class III malocclusion, characterized by a retarded and constricted maxilla, anterior and posterior crossbite. This patient underwent extraction of two lower Ist premolar. After extraction, author placed multibanded system in lower dental arch to change the long axis of anterior teeth and delivered removable appliance with Coffin spring in the upper dental arch to expand dental arch. After 13 months, anterior & posterior crossbite was corrected and this patient's profile was improved. Superimposition of pretreatment and posttreatment cephalograms upon the SN line registered at S showed backward downward rotation of the mandible and retrusion of lower lip.

  • PDF