• 제목/요약/키워드: Axial tomography

검색결과 206건 처리시간 0.026초

증기폭발 적용 축방향 토모그라피 기술 개발 (Development of axial tomography technique for the study of steam explosion)

  • 서시원;하광순;홍성완;송진호;이재영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3027-3032
    • /
    • 2007
  • To understand the complex phenomena performed in steam explosion, the fast and global measurement of the steam distribution is imperative for this extremely rapid transient stimulation of the bubble breakup and coalescence due to turbulent eddies and shock waves. TROI, the experimental facility requests more robust sensor system to meet this requirement. In Europe, researchers are prefer a X-ray method but this method is very expensive and has limited measurement range. There is an alternative technology such as ECT. Because of TROI's geometry, however, we need axial tomography method. This paper reviews image reconstruction algorethms for axial tomography, including Tikhonov regularization and iterative Tikhonov regularization. Axial tomography method is examined by simulation and experiment for typical permittivity distributions. Future works in axial tomography technology is discussed.

  • PDF

Partial Spectrum Detection and Super-Gaussian Window Function for Ultrahigh-resolution Spectral-domain Optical Coherence Tomography with a Linear-k Spectrometer

  • Hyun-Ji, Lee;Sang-Won, Lee
    • Current Optics and Photonics
    • /
    • 제7권1호
    • /
    • pp.73-82
    • /
    • 2023
  • In this study, we demonstrate ultrahigh-resolution spectral-domain optical coherence tomography with a 200-kHz line rate using a superluminescent diode with a -3-dB bandwidth of 100 nm at 849 nm. To increase the line rate, a subset of the total number of camera pixels is used. In addition, a partial-spectrum detection method is used to obtain OCT images within an imaging depth of 2.1 mm while maintaining ultrahigh axial resolution. The partially detected spectrum has a flat-topped intensity profile, and side lobes occur after fast Fourier transformation. Consequently, we propose and apply the super-Gaussian window function as a new window function, to reduce the side lobes and obtain a result that is close to that of the axial-resolution condition with no window function applied. Upon application of the super-Gaussian window function, the result is close to the ultrahigh axial resolution of 4.2 ㎛ in air, corresponding to 3.1 ㎛ in tissue (n = 1.35).

치과 임프란트 치료 계획을 위한 나선형 일반 단층촬영과 전산화 단층촬영시 흡수선량 및 유효선량 평가 (Absorbed and effective dose from spiral and computed tomography for the dental implant planning)

  • 홍병희;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제31권3호
    • /
    • pp.165-173
    • /
    • 2001
  • Objectives : To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. Materials and Methods: For radiographic projection, TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophagus. Effective dose was calculated, using the method suggested by Frederiksen et al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. Results: The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Conclusions: Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  • PDF

소아 심장 CT검사 시 Wide Coverage Volume Axial Mode의 유용성 평가 (Evaluation of the Availability of the Wide Coverage Volume Axial Mode in Pediatric Cardiac CT)

  • 박기석;김동현
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.683-689
    • /
    • 2019
  • 소아의 선천적 심장질환 진단을 위해 High Pitch Mode를 사용하여 획득한 소아 심장 CT 영상과 Wide Coverage Volume Axial Mode를 사용하여 획득한 소아 심장 CT 영상으로부터 환자의 피폭선량과 각 영상의 화질을 비교 및 분석하여 Wide Coverage Volume Axial Mode의 유용성을 평가해보고자 한다. 소아 심장 CT 검사 시 High Pitch Mode와 Wide Coverage Volume Axial Mode를 각각 50명 총 100명의 환자를 대상으로 시행하였으며, 각 프로토콜로부터 얻은 영상을 이용하여 환자의 피폭선량을 비교하였다. 각 영상에 ROI를 설정해 SNR과 CNR을 산출하여 영상의 화질을 비교하였다. High Pitch Mode에 비해 Wide Coverage Volume Axial Mode를 사용하여 검사하였을 때 환자의 피폭선량이 13.07% 감소하였고, SNR과 CNR이 향상되었다. Wide Coverage Volume Axial Mode는 고속 회전 스캐너를 이용하여 조사시간을 줄이고, 저선량 기술인 ASi R-V를 통해 High Pitch Mode를 사용했을 때보다 환자의 피폭선량이 감소하고 영상의 화질 또한 향상되는 유용한 검사라 할 수 있다.

Light-Microscopy-Based Sparse Neural Circuit Reconstruction: Array Tomography and Other Methods

  • Rah, Jong-Cheol
    • Applied Microscopy
    • /
    • 제46권4호
    • /
    • pp.176-178
    • /
    • 2016
  • Efficient neural circuit reconstruction requires sufficient lateral and axial resolution to resolve individual synapses and map a large enough volume of brain tissue to reveal the molecular identity and origin of these synapses. Sparse circuit reconstruction using array tomography meets many of these requirements but also has some limitations. In this minireview, the advantages and disadvantages of applicable imaging techniques will be discussed.

시간영역 광 간섭 단층촬영 시스템의 소형 엔도스코프 제작 및 영상구현 (Endoscopic Imaging and Fabrication of Micro-endoscope Catheter in Time-domain Optical Coherence Tomography)

  • 김영관;이성헌;김용평
    • 한국광학회지
    • /
    • 제21권5호
    • /
    • pp.206-213
    • /
    • 2010
  • 광 간섭 단층촬영 시스템(OCT)을 위한 소형의 광섬유 도관형 주사장치인 엔도스코프(endoscope catheter)를 제작하였다. 깊이방향 주사장치인 원통형 압전소자(PZT)를 이용한 광경로 지연기는 정현파 1 kHz로 구동하여 시간영역에서 엔도스코프 OCT 영상을 구현하였다. 정현파로 구동한 광경로 지연기의 속도는 6 m/s 이고, 깊이방향 스캐닝의 데이터 획득은 3 mm 기준에서 초당 2000 라인이다. 제작한 엔도스코프로 사람의 손가락 및 귀에 대한 초당 10프레임의 OCT 영상을 성공적으로 획득하였다.

Optimized Working Distance of a Micro-optic OCT Imaging Probe

  • Kim, Da-Seul;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.330-335
    • /
    • 2020
  • We have investigated optimization of the working distance (WD) for a highly miniaturized imaging probe for endoscopic optical coherence tomography (OCT). The WD is the axial distance from the distal end of the imaging probe to its beam focus, which is demanded for dimensional margins of protective structures, operational safety, or full utilization of the axial imaging range of OCT. With an objective lens smaller than a few hundred micrometers in diameter, a micro-optic imaging probe naturally exhibits a very short WD due to the down-scaled optical structure. For a maximized WD careful design is required with the optical aperture of the objective lens optimally filled by the incident beam. The diffraction-involved effect was taken into account in our analysis of the apertured beam. In this study, we developed a simple design formula on the maximum achievable WD based on our diffraction simulation. It was found that the maximum WD is proportional to the aperture size squared. In experiment, we designed and fabricated very compact OCT probes with long WDs. Our 165-㎛-thick fiber-optic probes provided WDs of 3 mm or longer w ith reasonable OCT imaging performance.

Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

  • Koh, Kwang-Joon;Kim, Kyoung-A
    • Imaging Science in Dentistry
    • /
    • 제41권3호
    • /
    • pp.101-106
    • /
    • 2011
  • Purpose : This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Materials and Methods : Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-$9000N^{TM}$ Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using $OnDemend3D^{TM}$. The new term "CTI" on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. Results : There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). Conclusion : CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

A Cerebral Astroblastoma Mimicking an Extra-axial Neoplasm

  • Eom, Ki-Seong;Kim, Jong-Moon;Kim, Tae-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권4호
    • /
    • pp.205-208
    • /
    • 2008
  • Astroblastoma is a rarely diagnosed primary brain neoplasm whose histogenesis has been clarified recently. It occurs in children and young adults and presents as a well circumscribed, contrast-enhancing lesion in the cerebral hemisphere. We present a case of 20-year-old woman with an astroblastoma in the left temporal convexity that was treated with total tumor resection alone. We thought the mass was extra-axial neoplasm based on radiological findings of computed tomography and magnetic resonance imaging initially, but later, we obtained angiographic findings suggesting an intra-axial neoplasm. The patient is doing well even two years after surgery. The characteristic radiological and histopathological features of this case are described with a literature review. An astroblastoma should be included in the differential diagnosis of a superficially located tumor presenting with the findings of an extra-axial mass, especially in a young patient.

Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

  • Sim, Sook Young;Choi, Chi Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권5호
    • /
    • pp.400-404
    • /
    • 2014
  • Objective : Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. Methods : Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the angle and number of streak artifacts in axial images, and the maximal diameter of artifacts in three-dimensional (3-D) volume-rendered images. The correlation coefficient (CC) was determined between each clip artifact type and the clip blade length and clip orientation to the CT scan (angle a, lateral clip inclination in axial images; angle b, clip gradient to scan plane in lateral scout images). Results : Angle b correlated negatively with white artifacts (r=-0.589, p<0.001) and positively with the angle (r=0.636, p<0.001) and number (r=0.505, p<0.001) of streak artifacts. Artifacts in 3-D images correlated with clip blade length (r=0.454, p=0.004). Multiple linear regression analysis revealed that angle b was the major parameter influencing white artifacts and the angle and number of streak artifacts in axial images (p<0.001), whereas clip blade length was a major factor in 3-D images (p=0.034). Conclusion : Use of a clip orientation perpendicular to the scan gantry angle decreased the amount of white artifacts and allowed better visualization of the clip site.