• 제목/요약/키워드: Axial Pump

검색결과 221건 처리시간 0.026초

Development of Prototype Multi-channel Digital EIT System with Radially Symmetric Architecture

  • Oh, Tong-In;Baek, Sang-Min;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권4호
    • /
    • pp.215-221
    • /
    • 2005
  • We describe the development of a prototype multi-channel electrical impedance tomography (EIT) system. The EIT system can be equipped with either a single-ended current source or a balanced current source. Each current source can inject current between any chosen pair of electrodes. In order to reduce the data acquisition time, we implemented multiple digital voltmeters simultaneously acquiring and demodulating voltage signals. Each voltmeter measures a differential voltage between a fixed pair of adjacent electrodes. All voltmeters are configured in a radially symmetric architecture to optimize the routing of wires and minimize cross-talks. To maximize the signal-to-noise ratio, we implemented techniques such as digital waveform generation, Howland current pump circuit with a generalized impedance converter, digital phase-sensitive demodulation, tri-axial cables with both grounded and driven shields, and others. The performance of the EIT system was evaluated in terms of common-mode rejection ratio, signal-to-noise ratio, and reciprocity error. Future design of a more innovative EIT system including battery operation, miniaturization, and wireless techniques is suggested.

엔진 냉각수 폐열 회수용 스크롤 팽창기 설계 (Design of a Scroll Expander for Waste Heat Recovery from Engine Coolant)

  • 유제승;김현재;김현진
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.815-820
    • /
    • 2011
  • A scroll expander was designed for an energy converter from waste heat of IC engine coolant to useful shaft work. The scroll expander is to run in a Rankine cycle which receives heat energy transferred from engine coolant circulation cycle. The working fluid was Ethanol. For axial compliance, a back pressure chamber was provided on the rear side of the orbiting scroll. Lubrication oil was delivered by a positive displacement type oil pump driven by the shaft rotation. Performance analysis on the scroll expander showed that the expander efficiency was 63.4%. It extracts shaft power of 0.6 kW out of engine coolant waste heat of 17.5 kW, resulting in the Rankine cycle efficiency of 3.43%.

Transition Analysis of Friction Factor According to Pumping Pressure in Pumping Test Using High Strength Concrete for High-rise Buildings

  • Kwon, Hae-Won;Kim, Young-Su
    • 한국건축시공학회지
    • /
    • 제13권4호
    • /
    • pp.400-406
    • /
    • 2013
  • In high-rise buildings, high-strength concrete is widely used to reduce the section of structure members under axial load. Also, the price increase of materials is very important item in the high-rise buildings. Especially, concrete used high-pressure pump due to consecutive structural assembly. Unlike slump type of ordinary concrete, high strength concrete has different properties of concrete pumping due to viscosity. However, there have been no Korean studies on the pumping properties of high strength concrete. Therefore, this paper measures the friction factor of high strength concrete with changes in the pressure of concrete pumping. We analyzed the trends of the friction factor based on changes in the pressure of concrete pumping, and then calculated the quantity of concrete deposited for each specified concrete strength and location of placement. After comparing these results with the quantity of concrete deposited measured in field, we evaluated the pumping properties of high strength concrete. Through the tests and the review, we attempt to suggest some basic information for the In-Situ application of high strength concrete.

사판식 액시얼 피스톤 펌프 가변용량 시스템의 윤활특성에 관한 연구 (A Study on the Lubrication Characteristics of a Compensator System for Swash Plate Type Axial Piston Pump)

  • 김신;송주현;정재연;이두형
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1994년도 제20회 학술대회
    • /
    • pp.54-58
    • /
    • 1994
  • 본 연구에서는 가변용량형 사판식 액시얼 피스톤 펌프의 가변용량 시스템에 있어서 actuator piston의 가공정도와 실린더사이의 간극의 변화에 따른 응답성 및 누설용량에 끼치는 영향을 살펴보았다. 가변용량형 사판식 액시얼 피스톤 펌프는 사판의 각도를 조절함으로써 유량을 조절하게 된다. 사판의 각도조절은 actuator piston에 의해 행해지며, 가변용량부의 어느 설정압력에 도달하면, 이 actuator piston이 사판을 밀어 사판의 각도를 변화 시키게 된다. 지배방정식으로는 spool과 사판의 운동방정식과 각 chamber의 누설 유량이 있다. 이들 방정식을 \ulcorner으로써 각 부분의 운동을 해석할 수 있게 된다. 여기에서 해석이 어려운 부분은 각 계수들의 결정이며 simulation을 할 때는 이로한 계수들을 이론적으로 결정을 하게 되고, 실험을 통해 검증하도록 한다. 즉, 각 운동뷰의 감쇠계수와 각 오리피스를 통한 유량계수, 그리고 감쇠계수 등은 실험을 통해 검토한다. 실험을 통한 측정에서는 각 chamber의 압력은 각 chamber에 연결된 압력센서 3개에 의해 행해지며, 사판의 각도는 angle 센서에 의해 측정하게 된다. 그리고 actuator piston과 블럭 사이의 간극을 조절하여 누설계수를 변화시키며, 그 영향을 살펴보았다.

  • PDF

전력반도체 냉각을 위한 원통형 루프히트파이프 제작 및 성능 평가에 관한 연구 (A Study on Manufacture and Performance Evaluation of a Loop Heat Pipe System with a Cylindrical Evaporator for IGBT Cooling)

  • 기재형;유성열;성병호;김성대;최지훈;김철주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1710-1716
    • /
    • 2008
  • The Loop Heat Pipe (LHP) operates to pump the working fluid by means of the capillary force in a wick structure. Particularly, it is difficult to design and manufacture the evaporator consisted of a grooved container and a compensation chamber as well as the wick structure. This study is related to design and manufacture the grooved container coupled with wick structure, the properties of the wick structure such as the permeability, the porosity, and the maximum capillary pressure were measured to apply the cooling technology for Insulated Gate Bipolar Transistor (IGBT). The container of the LHP was manufactured by the electrical discharge process and the wick structure was sintered with the nickel particle by an axial-press apparatus with the pulse electronic discharge. As results, the properties of the wick were experimentally obtained about 60% of the porosity, 35kPa of the maximum capillary force and $1.53{\times}10-13m2$ of the permeability.

  • PDF

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .

개구부를 가지는 전단벽의 숏크리트 보강 (Shotcrete-Retrofit of Shear Walls with an Opening)

  • 최윤철;최창식;김현민;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권5호
    • /
    • pp.71-80
    • /
    • 2007
  • 기존 시멘트에 비해 우수한 인장변형성능을 가지는 고인성 시멘트 복합체(HPFRCC)를 보수, 보강에 적용 시키려는 연구가 최근 활발히 진행되고 있다. 본 연구에서는 HPFRCC의 일종인 ECC와 초속경 숏크리트인 MDF의 보강성능을 알아보고자 한다. 실험체는 실존하는 철근콘크리트 구조물의 전단벽을 1/2 축소하여 제작하였으며 개구부를 가지고 있다. 실험결과 WB-MDF, ECC는 WB-0.23에 비해 각각 28.4%, 48.4%의 강도증가를 보였으며, 특히 WB-ECC가 WB-MDF에 비해 연성면에서 우수하게 나타났다.

앙와위와 좌측 기울린위치에서의 좌심실의 공간적 관계 변화. 임신부 심폐소생술 측면에서 (Spatial Relationship of the Left Ventricle in the Supine Position and the Left Lateral Tilt Position (Implication for Cardiopulmonary Resuscitation in Pregnant Patients))

  • 윤종근;이병국
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.75-79
    • /
    • 2013
  • 임신부의 경우 심폐소생술동안 좌측 기울림을 적용하도록 권장하고 있다. 하지만, 이 좌측으로 기울리면 임신부의 자궁 뿐만이 아니라 좌심실도 좌측으로 편위되어 심폐소생술의 심장펌프기능이 떨어질 가능성이 있다. 이에 좌측 기울림이 심폐소생술동안 흉골 운동 방향을 대변하는 전후축과 좌심실의 공간적 관계에 미치는 영향을 알아보고자 하였다. 컴퓨터 단층촬영을 이용한 가상내시경검사를 받은 90명의 환자를 대상으로 의무기록과 컴퓨터단층촬영결과를 후향적으로 조사하였다. 가상내시경은 앙와위와 좌측 기울림 위치 모두에서 실시되었다. 좌심실 단면적이 가장 넓은 축면에서 전후축과 좌심실축사이의 각도($Angle_{AP-LV}$), 전후축과 좌심실 중앙사이 최단거리($D_{AP-MidLV}$), 및 전후축과 좌심실첨부사이 최단거리($D_{AP-Apex}$)를 측정하였다. 대상환자 중 87명(96.7%)에서는 앙와위에서 좌심실이 전후축의 좌측에 위치하였다. 좌측으로 기울인 영상에서의 기울림 각도는 $43.4{\pm}11.0^{\circ}$였다. $D_{AP-MidLV}$$D_{AP-Apex}$는 좌측 기울린 위치에서 의미있게 길었지만 (p<0.001), AngleAP-LV는 두 자세 사이에 비슷했다. 심장정지인 임신부에서 좌측으로 기울림은 흉부압박의 심장펌프 효과를 떨어뜨릴 수도 있다.

Experimental evaluation of pumpjet propulsor for an axisymmetric body in wind tunnel

  • Suryanarayana, Ch.;Satyanarayana, B.;Ramji, K.;Saiju, A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제2권1호
    • /
    • pp.24-33
    • /
    • 2010
  • Design of a Pump Jet Propulsor (PJP) was undertaken for an underwater body with axisymmetric configuration using axial/low compressor design techniques supported by Computational Fluid Dynamics (CFD) analysis for performance prediction. Experimental evaluation of the PJP was earned out through experiments in a Wind Tunnel Facility (WTF) using momentum defect principle for propulsive performance prior to proceeding with extensive experimental evaluation in towing tank and cavitation tunnel. Experiments were particularly conducted with respect to Self Propulsion Point (SPP), residual torque and thrust characteristics over a range of vehicle advance ratio in order to ascertain whether sufficient thrust is developed at the design condition with least possible imbalance torque left out due to residual swirl in the slip stream. Pumpjet and body models were developed for the propulsion tests using Aluminum alloy forged material. Tests were conducted from 0 m/s to 30 m/s at four rotational speeds of the PJP. SPP was determined confirming the thrust development capability of PJP. Estimation of residual torque was carried out at SPP corresponding to speeds of 15, 20 and 25 m/s to examine the effectiveness of the stator. Estimation of thrust and residual torque was also carried out at wind speeds 0 and 6 m/s for PJP RPMs corresponding to self propulsion tests to study the propulsion characteristics during the launch of the vehicle m water where advance ratios are close to Zero. These results are essential to assess the thrust performance at very low advance ratios to accelerate the body and to control the body during initial stages. This technique has turned out to be very useful and economical method for quick assessment of overall performance of the propulsor and generation of exhaustive fluid dynamic data to validate CFD techniques employed.

A simple approach for quality evaluation of non-slender, cast-in-place piles

  • Zhang, Ray Ruichong
    • Smart Structures and Systems
    • /
    • 제4권1호
    • /
    • pp.1-17
    • /
    • 2008
  • This study proposes a conceptual framework of in-situ vibration tests and analyses for quality appraisal of non-slender, cast-in-place piles with irregular cross-section configuration. It evaluates a frequency index from vibration recordings to a series of impulse loadings that is related to total soil-resistance forces around a pile, so as to assess if the pile achieves the design requirement in terms of bearing capacity. In particular, in-situ pile-vibration tests in sequential are carried out, in which dropping a weight from different heights generates series impulse loadings with low-to-high amplitudes. The high-amplitude impulse is designed in way that the load will generate equivalent static load that is equal to or larger than the designed bearing capacity of the pile. This study then uses empirical mode decomposition and Hilbert spectral analysis for processing the nonstationary, short-period recordings, so as to single out with accuracy the frequency index. Comparison of the frequency indices identified from the recordings to the series loadings with the design-based one would tell if the total soil resistance force remains linear or nonlinear and subsequently for the quality appraisal of the pile. As an example, this study investigates six data sets collected from the in-situ tests of two piles in Taipu water pump project, Jiangshu Province of China. It concludes that the two piles have the actual axial load capacity higher than the designed bearing capacity. The true bearing capacity of the piles under investigation can be estimated with accuracy if the amplitude of impact loadings is further increased and the analyses are calibrated with the static testing results.