• 제목/요약/키워드: Avoid Cost(AC)

검색결과 8건 처리시간 0.021초

국가 및 전력회사의 관점에서 열병합발전의 편익산정에 관한 연구 (A Study on Calculation of Combined Heat and Power on Standpoint of Nation and Independent Power Producers)

  • 김용하;이평호;김영길;조현미;우성민
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.905-912
    • /
    • 2011
  • In this paper, the method on calculating benefits of combined heat and power is introduced for standard evaluation in electrical power system. This paper calculates benefits about new national viewpoint and viewpoint of independent power producers and assesses benefits of combined heat and power in Korea and In Seoul national capital area. Benefit costs are composed of avoid cost of centralized generation, line upgrading adjustment, loss adjustment and electrical power trade cost per year in earlier study, in addition trade cost of $CO_2$, construction cost of combined heat and power for accurate calculation. Benefit of combined heat and power is calculated by simulation results of real electrical power system.

누설 변압기를 이용한 반파 AC 주파수 제어형 $CO_2$ 레이저의 전원장치 개발 (The development on Power supply for Pulsed $CO_2$ laser using half-rectified AC frequency control and leakage transformer)

  • 정현주;김도완;이동훈;이유수;김희제;조정수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.82-85
    • /
    • 2000
  • We introduce pulsed $CO_2$ laser power supply excited by half-wave rectified 60Hz AC discharge some advantage of cost and size compared to a typical pulsed power supply. AC frequency is adjusted from 10Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage AC discharge circuits is employed to avoid the HV sampling or switching. The control is achieved by using a ZCS circuit and a PIC one-chip microprocessor that control the gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to a high leakage inductance. The maximum laser output was obtained about 20W at the condition of total pressure, 18Torr and pulse repetition rate,60Hz.

  • PDF

라그랑지 승수를 사용한 계통의 FACTS 기기 설치비용 함수의 최적화 기법 (Optimal technique of cost function for FACTS operation in power system using Lagrange Multipliers)

  • 박성욱;백영식;서보혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.15-17
    • /
    • 2004
  • The flexible AC transmissions system (FACTS) is the underpinning concept upon which are based promising means to avoid effectively power flow bottlenecks and ways to extend the loadability of existing power transmission networks. This paper proposes a method by which the optimal locations of the FACTS to be installed in power system under cost function. The optimal solution of this type of problem requires large scale nonlinear optimisation techniques. We used Lagrange multipliers to solve a nonlinear equation with equality and ineaquality constraints. Case studies on the standard IEEE 14 bus system show that the method can be implemented successfully and that it is effective for determining the optimal location of the FACTS

  • PDF

위상각와 주파수 제어에 따른 상용주파 AC 여기 방식의 펄스형 $CO_2$ 레이저 전원장치 개발에 관한 연구 (Output characteristics of ac excited $CO_2$ laser as a adjusting a phase angle and frequency)

  • 정현주;김도완;이동훈;김중만;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2098-2100
    • /
    • 2000
  • We propose pulsed $CO_2$ laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch) circuit and a PIC one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum laser output was obtained about 23W at pulse repetition rate of 60Hz, total gas mixture of $CO_{2}/N_{2}$/He = 1/9/15, SCR gate trigger angle 90$^{\circ}$, and total pressure of 18Torr.

  • PDF

상용교류방전 자기자극장치의 동작특성 (Commercial frequency AC discharge magnetic stimulation operating characteristics)

  • 김휘영
    • 한국정보통신학회논문지
    • /
    • 제13권12호
    • /
    • pp.2685-2692
    • /
    • 2009
  • 펄스형 자기자극장치를 누설변압기의 1차측 스위칭 제어로 교류(60hz) 스위칭 제어를 하여 비용과 크기면에서 기존의 전원장치로 구성된 것보다 약30w의 소용량으로 구성을 할 수가 있었다. 펄스반복률은 자기자극장치의 출력제어를 5-60hz로 적절하게 조절하였다. 이 자석 자극에서는, 고전압 출력 회로를 위한 낮은 전압 열리는 반복 통제가 고전압 표본 추출을 피하기 위하여 채택되며, 또는 스위칭제어와 고전압 누설 변압기는 고전압 하나로 조정된 낮은 전압 펄스를 개조하기 위하여 사용된다. ZCS (영전류스위칭) 회로 및 DSP & FPGA는 SCR의 게이트 신호를 정확하게 통제하기 위하여 사용된다. 펄스 반복 비율은 AC 선과 높은 누설 유도자의 주파수 때문에 60Hz에 의해 제한된다. 최대 자석자극장치의 출력은6 0Hz, 각각 40, 80, 120, $160^{\circ}$, SCR 게이트의 펄스반복 비율로 33W에 관하여 트리거 각 $90^{\circ}$에 대한 전체적인 출력으로 얻어졌다.

Characteristics of Non-Isolated OSAKA Converter -Characteristics of Three-Phase Soft-Switching Power Factor Corrected Converter for Large Scale Power Without Three-Phase Transformer-

  • Taniguchi, Katsunori;Shimomori, Wataru;Lee, Hyun-Woo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1383-1386
    • /
    • 2005
  • Non-isolated OSAKA Converter, which removes a three-phase transformer, is described in this paper. The converter switches once in every half cycle of an AC commercial power source. Therefore, it can solve many problems caused by the high frequency operation. The proposed converter achieves the soft-switching operation and the EMI noise can be reduced. In this circuit, the resonant capacitor, which is used for the soft-switching operation, is utilized for the improvement of an input current waveform. To achieve low cost and compact structure, non-isolated OSAKA converter removes a three-phase transformer of the OSAKA converter. By removing the three-phase transformer, three phase currents occur the interferences each other. To avoid the interference, a new switching method for non-isolated OSAKA converter is preposed. The converter can be constructed by the low-speed large power devices. The converter generates the low distorted input current waveforms with high power factor.

  • PDF

전력흐름 제어를 위한 FACTS 제어기의 위치 선정 (Optimal location of FACTS controller for power flow)

  • 박성욱;서보혁;백영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.16-18
    • /
    • 2004
  • The flexible AC transmissions system (FACTS) is the underpinning concept upon which are based promising means to avoid effectively power flow bottlenecks and ways to extend the loadability of existing power transmission networks. This paper proposes a method by which the optimal locations of the FACTS to be installed in power system under cost function. The optimal solution of this type of problem requires large scale nonlinear optimization techniques. We used Lagrange multipliers to solve a nonlinear equation with equality and ineaquality constraints. Case studies on the standard IEEE 14 bus system show that the method can be implemented successfully and that it is effective for determining the optimal location of the FACTS.

  • PDF

Optimal Location of FACTS Devices Using Adaptive Particle Swarm Optimization Hybrid with Simulated Annealing

  • Ajami, Ali;Aghajani, Gh.;Pourmahmood, M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.179-190
    • /
    • 2010
  • This paper describes a new stochastic heuristic algorithm in engineering problem optimization especially in power system applications. An improved particle swarm optimization (PSO) called adaptive particle swarm optimization (APSO), mixed with simulated annealing (SA), is introduced and referred to as APSO-SA. This algorithm uses a novel PSO algorithm (APSO) to increase the convergence rate and incorporate the ability of SA to avoid being trapped in a local optimum. The APSO-SA algorithm efficiency is verified using some benchmark functions. This paper presents the application of APSO-SA to find the optimal location, type and size of flexible AC transmission system devices. Two types of FACTS devices, the thyristor controlled series capacitor (TCSC) and the static VAR compensator (SVC), are considered. The main objectives of the presented method are increasing the voltage stability index and over load factor, decreasing the cost of investment and total real power losses in the power system. In this regard, two cases are considered: single-type devices (same type of FACTS devices) and multi-type devices (combination of TCSC, SVC). Using the proposed method, the locations, type and sizes of FACTS devices are obtained to reach the optimal objective function. The APSO-SA is used to solve the above non.linear programming optimization problem for better accuracy and fast convergence and its results are compared with results of conventional PSO. The presented method expands the search space, improves performance and accelerates to the speed convergence, in comparison with the conventional PSO algorithm. The optimization results are compared with the standard PSO method. This comparison confirms the efficiency and validity of the proposed method. The proposed approach is examined and tested on IEEE 14 bus systems by MATLAB software. Numerical results demonstrate that the APSO-SA is fast and has a much lower computational cost.