• 제목/요약/키워드: Averaged CT

검색결과 37건 처리시간 0.02초

PCVN 시편 파괴인성의 균열 깊이 영향에 대한 Scaling 모델 해석 (Analysis of Cleavage Fracture Toughness of PCVN Specimens Based on a Scaling Model)

  • 박상윤;이호진;이봉상
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.409-416
    • /
    • 2009
  • Standard procedures for a fracture toughness testing require very severe restrictions for the specimen geometry to eliminate a size effect on the measured properties. Therefore, the used standard fracture toughness data results in the integrity assessment being irrationally conservative. However, a realistic fracture in general structures, such as in nuclear power plants, may develop under the low constraint condition of a large scale yielding with a shallow surface crack. In this paper, cleavage fracture toughness tests have been made on side-grooved PCVN (precracked charpy V-notch) type specimens (10 by 10 by 55 mm) with various crack depths. The constraint effects on the crack depth ratios were evaluated quantitatively by the developed scaling method using the 3-D finite element method. After the fracture toughness correction from scaling model, the statistical size effects were also corrected according to the standard ASTM E 1921 procedure. The results were evaluated through a comparison with the $T_0$ of the standard CT specimen. The corrected $T_0$ for all of the PCVN specimens showed a good agreement to within $5.4^{\circ}C$ regardless of the crack depth, while the averaged PCVN $T_0$ was $13.4^{\circ}C$ higher than the real CT test results.

셀룰라 휴대폰에 의한 인체 두부의 SAR 해석 (Analysis of SAR in a Human Head for a Cellular Phone)

  • 이애경;최형도;김진석
    • 한국전자파학회논문지
    • /
    • 제9권6호
    • /
    • pp.776-787
    • /
    • 1998
  • 835 MHz에서 동작하는 셀룰라 휴대폰에 의한 인체 두부내의 1 g 및 10 g 평균 비홉수율(specific absorption rate, SAR)을 해석한다. 사용되는 수치방법은 총 전자기장 유한차분 시간영역(finite-difference time-domain, FDTD) 기법이다. 전화기는 도체박스, 플라스틱 케이스 그리고 모노폴 안테나와 나선형 안테나 로 구성된 whip 안테나로 모의되었다. 공간 정밀도 3 mm의 이산적 인체두부 모델은 MRI(Magnetic Resonance Imaging), CT(computerized tomography) 그리고 해부학적 이미지에 기초한 것이다 안테나를 뽑은 전화기와 접은 전화기에 대한 근역장 및 원역장 복사 패턴이 분석되었다. SAR 평가를 위한 재현성 있는 기법을 제공하기 위해 조직내의 1 g 또는 10 g의 질량을 갖는 체적을 취하는 두 가지 방법을 제안하고 비교 한다.

  • PDF

NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가 (Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard)

  • 이병일
    • 통합자연과학논문집
    • /
    • 제1권2호
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF

PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교 (A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT)

  • 이승재;박훈희;안샤론;오신현;남궁혁;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.235-240
    • /
    • 2008
  • PET/CT 검사의 사용 초기에 CT는 주로 감쇠보정(Attenuation Correction: AC)의 목적으로 사용되어졌지만, CT의 성능이 향상됨으로써 조영제를 이용한 CT검사를 진단에 반영하여 보다 진보된 진단적 가치를 가질 수 있게 되었다. 조영제의 사용이 없이도 CT를 판독할 수 있지만 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 있어서 조영제의 사용은 판독자로 하여금 판독을 매우 용이하게 하는 도움을 줄 수 있다. 하지만, 그동안 PET/CT검사 시 조영제가 감쇠보정에 영향을 줄 수 있다는 논쟁으로 이견이 많았다. 40-140 keV 정도의 낮은 엑스선을 이용하는 CT영상에 비하여, 조영제를 사용한 CT영상에서는 조영제로 인해 감쇠가 많이 되지만 511 keV의 에너지를 가진 감마선은 조영제로 인해 거의 영향을 받지 않게 되고 이로 인해 감쇠보정 시 과보정을 하게 되어 PET영상에서 오류를 나타낼 수 있다는 의견이 보고되기도 하였다. 이와는 반대로 조영제가 감쇠보정에 과대평가를 가져올 수 있다는 의견과 과보정으로 인한 표준화섭취계수에 변화의 가능성은 있으나 결정적인 영향을 미치지 않는다는 의견도 제시되었다. 본 연구에서는 조영제의 영향이 SUV에 어떠한 영향을 미치는지에 대해서만 비교 평가하였다. 2007년 12월에서 2008년 6월 사이에 본원에서 PET/CT 검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 진행성 암 환자 30명을 대상으로 하였으며, DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하여, 각각의 환자는 조영제를 사용하지 않은 CT를 시행한 후 PET영상을 얻었고 그 후, 조영제를 사용한 CT검사를 하였다. 각각의 CT정보로 감쇠보정을 실시, 종류별로 PET영상을 획득하여, 각 영상에 동일한 관심영역(Region of Interests : ROIs)을 설정 후, SUV를 비교 하였다. 얻어진 두 가지 결과 값의 정량 분석의 비교를 위해서 대응표본 T-검정 (Paired t-test)을 사용하였다. 검사를 시행한 30명의 환자에게서 폐, 간, 심장의 $SUV_{max}$ 값과 $SUV_{mean}$값을 측정하여 총 180개 영역을 분석하였다. 조영제를 사용하기 전과 후를 비교하였을 때, 측정한 거의 모든 영역에서 조영 후의 $SUV_{max}$$SUV_{mean}$가 상승하였고 통계적으로도 유의한 것으로 나타났다(p value<0.05). 심장 영역에서 조영 전 보다 조영 후의 $SUV_{mean}$값이 증가된 것으로 나타났지만, 통계적으로 유의하게 나타나지는 않았다. 조영제를 사용한 CT영상의 SUV값이 과보정되어, 조영제를 사용하지 않은 CT의 SUV 보다 높게 나왔으나 기존의 보고된 논문에서는 이와 같은 결과는 실제 임상 판독에 있어서 큰 영향을 미치지 않는다고 보고되어 있다. 그러나 원발성병변의 진행을 알아보는 과정에서는 SUV의 작은 변동도 분명 영향을 줄 수 있으므로 간 영역과 같이 SUV의 변동이 다른 영역에 비해 상대적으로 큰 영역에서는 수치의 변화에 대한 주의가 요구 될 것으로 사료된다.

  • PDF

충주댐 유역의 SWAT-K와 HSPF모형에 의한 수문성분 모의특성 비교 분석 (Comparison of SWAT-K and HSPF for Hydrological Components Modeling in the Chungju Dam Watershed)

  • 김남원;신아현;김철겸
    • 한국환경과학회지
    • /
    • 제18권6호
    • /
    • pp.609-619
    • /
    • 2009
  • SWAT-K model is a modified version of the original SWAT, and is known to more accurately estimate the streamflows and pollutant loadings in Korean watersheds. In this study, its hydrological components were compared with those of HSPF in order to analyse the differences in total runoff including evapotranspiration(ET), surface flow, lateral flow and groundwater flow from the Chungju Dam watershed during $2000{\sim}2006$. Averaged annual runoff with SWAT-K overestimated by 1%, and HSPF underestimated it by 3% than observed runoff. Determination coefficients($R^2$) for observed and simulated daily streamflows by both the models were relatively good(0.80 by SWAT-K and 0.82 by HSPF). Potential ET and actual ET by HSPF were lower in winter, but similar or higher than those by SWAT-K. And though there were some differences in lateral and groundwater flows by two models because of the differences in hydrological algorithms, the results were to be reasonable. From the results, it was suggested that we should utilize a proper model considering the characteristic of study area and purposes of the model application because the simulated results from same input data could be different with models used. Also we should develop a novel model appropriate to Korean watersheds by enhancing limitations of the existing models in the future.

Development Treatment Planning System Based on Monte-Carlo Simulation for Boron Neutron Capture Therapy

  • Kim, Moo-Sub;Kubo, Kazuki;Monzen, Hajime;Yoon, Do-Kun;Shin, Han-Back;Kim, Sunmi;Suh, Tae Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.232-235
    • /
    • 2016
  • The purpose of this study is to develop the treatment planning system (TPS) based on Monte-Carlo simulation for BNCT. In this paper, we will propose a method for dose estimation by Monte-Carlo simulation using the CT image, and will evaluate the accuracy of dose estimation of this TPS. The complicated geometry like a human body allows defining using the lattice function in MCNPX. The results of simulation such as flux or energy deposition averaged over a cell, can be obtained using the features of the tally provided by MCNPX. To assess the dose distribution and therapeutic effect, dose distribution was displayed on the CT image, and dose volume histogram (DVH) was employed in our developed system. The therapeutic effect can be efficiently evaluated by these evaluation tool. Our developed TPS could be effectively performed creating the voxel model from CT image, the estimation of each dose component, and evaluation of the BNCT plan.

A Morphometric Aspect of the Brachial Plexus in the Periclavicular Region

  • Lee, Jung-Pyo;Chang, Jae-Chil;Cho, Sung-Jin;Park, Hyung-Ki;Choi, Soon-Kwan;Bae, Hack-Gun
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권2호
    • /
    • pp.130-135
    • /
    • 2009
  • Objective: The purpose of this study was to determine the normal morphometric landmarks of the uniting and dividing points of the brachial plexus (BP) in the periclavicular region to provide useful guidance in surgery of BP injuries. Methods: A total of 20 brachial plexuses were obtained from 10 adult, formalin-fixed cadavers. Distances were measured on the basis of the Chassaignac tubercle (CT), and the most lateral margin of the BP (LMBP) crossing the superior and inferior edge of the clavicle. Results: LMBP was located within 25 mm medially from the midpoint in all subjects. In the supraclavicular region, the upper trunk uniting at 21$\pm$7 mm from the CT, separating into divisions at 42$\pm$5 mm from the CT, and dividing at 19$\pm$4 mm from the LMBP crossing the superior edge of the clavicle. In the infraclavicular region, the distance from the inferior edge of the clavicle to the musculocutaneous nerve (MCN) origin was 49$\pm$12 mm, to the median nerve origin 57$\pm$7 mm, and the ulnar nerve origin 48$\pm$6 mm. From the lateral margin of the pectoralis minor to the MCN origin the distance averaged 3.3$\pm$10 mm. Mean diameter of the MCN was 4.3$\pm$1.1 mm (range, 2.5-6.0) in males (n = 6), and 3.1$\pm$1.5 mm (range, 1.6-4.0) in females (n = 4). Conclusion: We hope these data will aid in understanding the anatomy of the BP and in planning surgical treatment in BP injuries.

PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성 (Evaluation of Average CT to Reduce the Artifact in PET/CT)

  • 김정선;남기표;박승용;류재광;차민경
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.3-7
    • /
    • 2010
  • 종양학에서 암의 진단, 병기 결정, 재발 판정, 그리고 치료에 대한 반응의 평가에 PET/CT의 유용함은 이미 인정되고 있다. 그런데 크기가 작거나 폐의 기저 부위, 혹은 간의 상부에 위치한 종양일수록 호흡으로 인한 위치 변위와 왜곡의 정도가 크며 PET영상의 SUV에도 영향을 미치게 된다. 따라서 정상 호흡 상태에서 얻어지는 PET 또는 CT영상을 토대로 방사선 치료를 하게 되면 치료해야 할 표적이 치료 범위에서 벗어나거나 정상 조직에 과도한 방사선이 조사될 수 있으므로 치료율이 낮아지거나 방사선에 의한 부작용이 증가할 수 있다. 본 논문의 목적은 호흡에 의한 인공산물을 최소화하고 보다 정확한 SUV 측정을 위해 ACT를 이용한 감쇠 보정 방법을 적용하여 그 유용성을 평가하고자 함이다. 하 흉부에 종양이 있는 13명의 환자를 대상으로 Discovery STE8 PET/CT스캐너를 사용하여 두 가지의 PET/CT영상을 얻었다. HCT를 사용한 감쇠 보정 영상과 ACT를 사용한 감쇠 보정 영상에서 측정한 인공물의 크기와 $SUV_{max}$를 비교 분석하였다. 인공물은 모든 환자의 하 흉부의 백색 음영 영역을 측정하여 평가하였다. $SUV_{max}$는 주요 종양의 $SUV_{max}$를 측정하여 평가하였다. 분석 프로그램은 Advantage Workstation v4.3을 사용하였다. 환자에게 7.4 MBq (0.2 mCi)/kg의 $^{18}F$-FDG를 투여한 1시간 뒤 스캔하였다. 방출 스캔은 3 min/bed로 스캔하였다. HCT 보정 영상과 비교하여 ACT 보정 영상에서 인공산물의 크기가 눈에 띄게 줄어든 것을 관찰할 수 있었다. 하 흉부의 저 보정으로 인한 인공산물 크기는 ACT 보정 영상과 HCT 보정 영상 각각 $1.5{\pm}3.5$ cm과 $13.4{\pm}4.2$ cm를 나타냈다. 주요 병소의 $SUV_{max}$의 변화는 ACT 보정 영상이 HCT 보정 영상보다 눈에 띄게 상승하였다. ACT 보정 영상에서 HCT영상과 비교하여 tumor의 $SUV_{max}$가 평균 $5.3{\pm}3.9%$ 상승하였다. 가장 큰 차이를 보인 종양은 lung의 lower lobe에 있는 종양으로 $SUV_{max}$ 7.7에서 $SUV_{max}$ 8.7로 13% 상승하였다. ACT를 이용한 감쇠 보정 영상은 하 흉부의 인공산물을 눈에 띄게 줄일 수 있어 보다 정확한 병소의 SUV를 측정 및 방사선 치료 범위 설정에 도움이 될 수 있을 것이다. 또한 ACT 기법은 병소가 횡격막 부근에 있는 환자의 경우 폐와 간의 경계를 보다 정확히 구분할 수 있어 판독시 도움이 될 수 있을 것이라고 판단된다. 추가 ACT 촬영에 의한 피폭 선량이 증가하는 점을 고려하여 적용한다면 임상적으로 유용한 효과가 있다고 사료된다.

  • PDF

긴 유리섬유강화 Polypropylene 복합재료의 섬유 중량비에 따른 파괴인성 변화 (Effect of Fiber Weight Fraction on the Fracture Toughness of Long Glass-Fiber Reinforced Polypropylene Composites)

  • 이경엽;이중희;양준호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.164-167
    • /
    • 1999
  • This study concerns with the effect of fiber weight fraction on the fracture toughness of long glass-fiber reinforced polypropylene composites. Fracture tests were conducted using compact tension (CT) specimens made of glass fiber polypropylene composites. Three fiber weight fractions of 20%, 30%, and 40% were used. Fracture toughness was determined from the compliance method. Results showed that compliance decreased with increasing fiber weight fraction while critical load increased with fiber weight fraction. Averaged fracture toughness increased 14% as fiber weight fraction increased from 20% to 40%.

  • PDF

경골 근위부 골채취를 위한 내측 및 외측 접근법시의 삼차원적 길이계측 (THREE DIMENSIONAL LINEAR MEASUREMENT OF PROXIMAL TIBIA IN MEDIAL AND LATERAL APPROACH FOR BONE HARVESTING)

  • 남웅;박원서;정호걸;허경석;차인호
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.307-311
    • /
    • 2007
  • Purpose: The aim of this study was simply assessing linear measurements in the lateral and medial approach, respectively, for bone harvesting using anatomic and three-dimensional(3D) computed tomographic(CT) analyses on a dried cadaveric proximal tibia. In addition, the availability of the three-dimensional computed tomographic(3D-CT) analysis was also estimated. Materials and methods: Ten dried proximal tibia were obtained from five Korean cadavers. Four the reference points, the SM(superior-medial), IM(inferior-medial), SL(superior-lateral), and IL(inferior-lateral) were marked around the tibial tuberosity. The PM(posterior-medial) and PL(posterior-lateral) points were randomly marked at points farthest from the lateral and medial reference points, respectively, in the posterior border of the superior articular surface of both condyles. All measurements were obtained on the dried proximal tibia. After computed tomography had been performed, the three dimensional images were reconstructed using V works $4.0^{TM}$(Cybermed Inc., Seoul, Korea), and the length between the reference points were measured three dimensionally using the method described above. The error between the mean actual and mean 3D-CT measurements was calculated in order to determine the availability of the three dimensional computed tomographic analysis. Results: The length between the reference points was greatest at the IL-PM, which averaged $65.39mm{\pm}10.35$. This was followed by the SL-PM with $63.24mm{\pm}8.10$, the IM-PL with $58.09mm{\pm}10.02$, and the SM-PL with $51.99mm{\pm}9.06$. The differences between the IL-PM and SM-PL were 13.4 mm. The mean values were 55.04 mm in the medial approach and 64.32 mm in the lateral approach, and the differences between medial and lateral were 9.28 mm. The error between the mean actual and mean 3D-CT measurements was 0.31% and the standard deviation was 0.28%. Conclusion: The anatomical and three dimensional computed tomographic analysis indicates that there was only a 9.28 mm linear difference between the lateral and medial approach. This is consistent with previous studies, which showed that there was little difference between the two approaches in terms of the bone volume. In addition, the error(0.31%) and the standard deviation(0.28%) were considered low, demonstrating high accuracy of 3D-CT. Therefore it can be used in preoperative treatment planning.